6. Setting Up Bar Code Symbol
Bar code symbols can be set up.
Scan ON/OFF bar code after scanning the bar code on bar code symbols.
▪ (Example) To set up and use with UPC-A Leading zero symbol,
enter [START], [UPC-A Leading zero], [ON], [END]
For symbols on bar code below, enter set point after scanning the symbol bar
code.
① Supplementcode
▪ Basic Set Point: 0
Number Description
0 Disable: Will not recognize supplement code
1 Decode: Must recognize Supplementcode in order
to be recognized as correct bar code.
2 Autodiscriminat: With or without the
Supplementcode, will recognize bar code.
▪ Only the numbers 0~2 to be entered otherwise setting will be
cancelled.
② Interleaved 2 of 5 Length Min: Set up minimum cognition length
▪ Basic Set Point: 3
▪ Numbers 0~255 to be entered otherwise setting will be
cancelled.
▪ (Example) In order to set up minimum cognition length of
Interleaved 2 of 5 Length Min to 12, enter [START],
[Interleaved 2 of 5 Length Min], [1], [2], [END]
③ Interleaved 2 of 5 Length Max: Set up Maximum cognition length
▪ Basic Set Point: 30
▪ Enter numbers 0~255 otherwise setting will be cancelled
④ MSI check digit: Set up Check Digit. It is the method to inspect whether
the barcode is correct
▪ Basic Set point: Check_1
▪ Basic Set Point: Check_1