INSTRUCTIONS FOR THE INSTALLATION, USE AND MAINTENANCE OF
PISKO SAFEGRIP WALL LADDER
PARTS OF THE WALL LADDER
1. Pisko SafeGrip ladder
2. Bow
3. Bow fastener for wall ladder
4. Bow fastener for the roof (L-model)
5. Bow fastener for the ladder (U-model)
6. Bow fastener kit for walkway
8. Wall ladder leg
9. Wall ladder clip
10. Eaves support
11. Fixing plate for wall ladder fastener

INSTALLATION
center line of the ladder’s rungs and the eaves or other protrusion is at least
taken to prevent water trickling down the wall from entering the wall
The wall ladder legs are fastened to the ladder with wall ladder clips and M8
screws and nuts so that the topmost pair of legs is located as close to the
The wall ladder legs are fastened to the eaves structure with the aid of eaves
eaves support is fastened to the wall ladder leg with an M8x30 hexagon screw
and M8 hexagon nut and to the eaves with e.g. 7x40 mm HVAC screw (2 per eaves
support).
2 x
7*40 mm
HVAC screw
Timber frame or
paneled wall: 4 x
7*40/50 mm
HVAC screw
Concrete/stone/block wall:
nylon or metal plug
suitable for the material in
question + 4 x 7*40/50 mm
HVAC screw
Sandwich panel:
Pisko fixing plate for wall
ladder fastener +
Pisko sheet metal screw
•
•
•
•
•
•
*) t
tested with wall ladder
legs up to 1200 mm
length. Wall ladder legs
longer than this may not
fully comply with the
requirements of the
The ladder frame is fastener to the wall ladder legs with wall ladder clips
using two M8x16 and one M8x40 hexagon screws and M8 hexagon nut per
clip
200-1200 mm *
NOTE! IF A SAFETY RAIL IS
FASTENED TO THE LADDER, AT
LEAST FOUR PAIRS OF WALL
LADDER LEGS MUST BE USED!
Minimum distance between
the rung and the nearest
protrusion: 200 mm
Maximum distance between the pairs
of wall ladder legs: 3,000 mm
Distance to the bottom
rung: 1,000–1,200 mm

•
the L-shaped fastener.
• The U-shaped fastener is placed around the ladder’s rail and secured
with two M8x40 hexagon screws and M8 hexagon nuts.
•
•
each roof truss.
• The fastener interval is approximately 300 mm.
•
•
with two M8x40 hexagon screws M8 hexagon nuts.
Fastening the Wall Ladder to the Roof Ladder
Fastening the Wall Ladder to the Roofing
Fastening the Wall Ladder to the Roof Walkway
Fastening the Wall Ladder to a Tiled Roof
•
roof walkway.
an L-shaped fastener.
•
hexagon screw and an M8 hexagon nut.
•
•
• The connector is fastened to the roof walkway with two M8x16 hexagon screws
and M8 hexagon nuts.
•
hexagon nuts.
2 x
7*40/50 mm
HVAC screw
4 x
7*40/50 mm
HVAC screw

The ladder
used
of the ladder or other Pisko product retailer.
Fastening the Bows to the Ladder Frame
USE
•
roof-side end. The coupling is secured with an M8x40 hexagon screw and
an M8 hexagon nut.
•
the wall ladder clip and secured with two M8x16 screws and one M8x40
hexagon screw and one M8 hexagon nut.
Installing the Anti-Climb Plate
securely in its place.
•

MAINTENANCE
Ladders are
not intended to be used as snow guards.
• Taking care of the removal of excess snow in order to minimize the load on the structures and fastening points
damages
•
Company
INSTALLED BY
Installer
Date

Piristeel Oy
FI-62200 Kauhava
Product
Intended purpose
Performance levels
1. Dimensions
capacity and torque
resistance
Pisko wall ladder
Value
a) Rung width 400 mm
c) Rung diameter 25 mm
4. Corrosion Corrosion resistance class C3 medium
kN.
- Withstand a load of 2.6 kN.
d) Torque-resistance capacity of the rung’s fastening
- Withstands a torque of 50 Nm.
Version 1.5
28.06.2022
Piristeel Oy |Metallitie 4, 62200 Kauhava, Finland
Tel. +358 6 433 8800 |www.piristeel.fi
Table of contents
Other pisko Ladder manuals
Popular Ladder manuals by other brands

Dolle
Dolle Gardentop Installation instruction

Hard Head
Hard Head 021718 operating instructions

MetalTech
MetalTech ScaffLock I-ISL OPERATIONAL SAFETY AND ASSEMBLY INSTRUCTIONS

BURGER
BURGER SPARK 794 manual

PRIMAL TREESTANDS
PRIMAL TREESTANDS PVHA-100 Instruction and safety manual

GIERRE
GIERRE Scalamia AL130 Operating and maintenance instructions