Pittsburgh Modular Lifeforms Touch Controller User manual

The Voltage Research Laboratory
Encyclopedia Touch Controller Manual

2
Thank you!
Thank you for purchasing the Touch Controller. Your interest and investment in this unique controller
helps support innovative, boutique synthesizer design. The Touch Controller is a large part of the
unique vision for analog synthesis that Michael and I share.
Enjoy,
Richard Nicol
Founder | Product Design
Pittsburgh Modular Synthesizers
Voltage Research Laboratory Team
Product Design: Richard Nicol
Analog Engineering: Michael Johnsen
Logistics: Michael Importico
Fine Tuning: Perry Willig
Prototyping: Ross Johnson
Coordination: Danielle Nicol

3
Important Information
Read Instructions: Please read the Voltage Research Laboratory manual completely before use and
retain for future reference.
• IMPORTANT Ribbon Cable Power Information:
The Lifeforms Touch Controller is a eurorack format synthesizer module. The module can be
installed, rearranged, removed, and replaced in any compatible eurorack enclosure from
Pittsburgh Modular or other manufacturers. The Lifeforms Touch Controller uses a standard 10 to
16 pin eurorack ribbon cable to connect the module to a bipolar +/-12v power supply. Please pay
very close attention to the orientation of the ribbon cable when adding and removing modules. The
stripe on the ribbon cable marks -12v. This stripe needs to line up with the -12v pins on the power
rail and the -12v pins on the module. The Lifeforms Touch Controller includes reverse polarity
protection so it will not be damaged when plugged in incorrectly; however, as a general rule,
failure to match up the pins correctly can result in damage to one or all the modules in a case. On
a Pittsburgh Modular enclosure power rail, the -12v pins are clearly labeled. On the Lifeforms
Touch Controller module, the positive side of the pin connector is on top, and the negative sides of
the pin connector is on the bottom so the red stripe should be toward the bottom of the module.
• Turn off and unplug the power from the case before removing the Eurorack power header attached
to the Touch Controller module. Failing to turn off the power before removing the Eurorack power
header can damage the Touch Controller module.
• The Voltage Lab is an electronic device. Exposure to water will cause the Touch Controller
circuitry to short circuit and may cause permanent damage.
• Do not attempt to modify the components of the Touch Controller. Tampering with the circuitry
may cause permanent damage.
• Do not place heavy objects on the Touch Controller. The user interface is mounted on a PCB that
can be damaged if stressed by excessive weight.
• Do not attempt to repair the Touch Controller. Please contact Pittsburgh Modular regarding
malfunctions of any kind.
• Pittsburgh Modular is not responsible for any damage or loss caused by improper use of the
Touch Controller.
The Touch Controller Manual Revision 0

4
Table of Contents
Thank you!
Important Information
Table of Contents
User Interface Controls
Module Overview
User Interface Conventions
Left and Right Touch Zones
Controller Modes
Mono Mode Sequences
Duo Mode Sequences
Scan Mode
Eurorack Specs
Warranty
Service and Other Information
3
4
5
6
7
8
10
11
12
14
16
17
17
17

5
User Interface Controls
1. Channel Animator Section
2. Left Output Section
3. Right Output Section
4. All Output Section
5. Mono Button
6. Reset/Rest Button
7. Duo Button
8. Scan Input Jack
9. Reset Input Jack
10. Step Input Jack
11. Left Gate Output Jack
12. Left CV A Output Jack
13. Left CV B Output Jack
14. Left Y-Axis Output Jack
15. Right Gate Output Jack
16. Right CV A Output Jack
17. Right CV B Output Jack
18. Right Y-Axis Output Jack
19. All Gate Output Jack
20. All CV A Output Jack
21. All CV B Output Jack
22. All Y-Axis Output Jack
30. Channel 1 Voltage Preset Knob A
31. Channel 2 Voltage Preset Knob A
32. Channel 3 Voltage Preset Knob A
33. Channel 4 Voltage Preset Knob A
34. Channel 5 Voltage Preset Knob A
35. Channel 6 Voltage Preset Knob A
36. Channel 7 Voltage Preset Knob A
37. Channel 8 Voltage Preset Knob A
38. Channel 9 Voltage Preset Knob A
39. Channel 10 Voltage Preset Knob A
40. Channel 1 Voltage Preset Knob B
41. Channel 2 Voltage Preset Knob B
42. Channel 3 Voltage Preset Knob B
43. Channel 4 Voltage Preset Knob B
44. Channel 5 Voltage Preset Knob B
45. Channel 6 Voltage Preset Knob B
46. Channel 7 Voltage Preset Knob B
47. Channel 8 Voltage Preset Knob B
48. Channel 9 Voltage Preset Knob B
49. Channel 10 Voltage Preset Knob B
50. Touch Plate 1
51. Touch Plate 2
52. Touch Plate 3
53. Touch Plate 4
54. Touch Plate 5
55. Touch Plate 6
56. Touch Plate 7
57. Touch Plate 8
58. Touch Plate 8
59. Touch Plate 9

6
Module Overview
The Touch Controller is an interface for interacting with gates and voltages. The module
features 10 Touch Plates, each with 2 assignable analog voltage presets, Y-Axis response,
gate response, multiple performance modes, and pattern sequencing.
The interface of the Touch Controller was designed to be intuitive with direct access to all of
the functions. The knobs on the Touch Controller set the analog voltage preset values for
the touch plates while the 3 buttons in the Channel Animator section manage performance
modes and sequencer settings.
Using the Touch Controller requires a basic understanding of both the user interface and
Controller Modes. The touch surface is split into 2 Touch Zones, Left and Right. Each Touch
Zone has 5 Touch Plates and a dedicated output section. The Left Output Section always
responds to the Left Touch Zone and the Right Output Section always responds to the Right
Touch Zone. The response of the All Output Section is determined by the active Controller
Mode.

7
User Interface Information
There are some user interface and general patching conventions that need to be understood to achieve
the best results from the Touch Controller.
Touch Plates
The Touch Controller has 10 Touch Plates. The Touch Plate checks for on/off status and reads the
nger position along the Y-Axis. The position is translated into a 0 to 5 volt CV signal. The unique
design of the Touch Plate attempts to minimize the impact of nger surface area when determining the
location but capacitive touch responds strongly to increased surface area. Pressing rmly, using more
of the nger, or using multiple ngers when touching the Touch Plates will have an effect on the output
voltage.
The 10 Touch Plates of the Touch Controller utilize capacitive touch technology to create an interactive
touch surface. Capacitive touch is far from perfect in the best of conditions. We have tuned our circuitry
and software to mitigate the side effects of capacitive touch but anomalies exist. The process of
measuring small amounts of change in capacitance to register a touch and determine y-axis location
and is sensitive to many outside variables. Different power sources can create a different capacitive
touch sensitivity response. The variation can be caused by both the +12v power supplied by the
eurorack case, the power mains, and most importantly, the quality of the earth ground the case is
plugged into. Also, because capacitive touch integrates the human body into the circuit, response can
very from person to person. Poor grounding, some uorescent lighting xtures, and some power strips
can cause problems with the response of the Touch Controller.

8
User Interface Information Section (2 of 2)
Patch Points
The Touch Controller uses Eurorack standard 1/8” mono jacks for all the patch points. Input jacks have
an outline around their name. Output jacks do not. The Touch Controller interface does not distinguish
between audio, CV, and gate signals. In theory, any output can be patched into any input. In practice,
inputs respond best when patched to the expected signal type. However, experimentation can yield
surprising results. The type of signal input and output of each jack is covered in the corresponding
section.
Voltage Preset Knobs
The two rows of Voltage Preset Knobs set the CV A and CV B analog, unquantized output voltages for
the corresponding Touch Plate. The top row sets CV A and the bottom row sets CV B. The knobs are
calibrated to output between 0 volts and 5 volts. The maximum output voltage can be modied using
the calibration trim pots on the rear of the unit between anywhere between 0 volts and 9 volts.
Button Functionality
All the buttons have 2 functions. A main function clearly labeled below and a sub-function printed in
parentheses. To access the sub-function, press and hold down the button before pressing a Touch
Plate. The main function and sub-function of each button is covered in the Channel Animator section.

9
Left & Right Touch Zones
Left & Right Touch Zones
The Touch Controller is split into 2 Touch Zones, Left and Right, each with 5 Touch Plates. The Touch
Zones allow the Touch Controller to always function as a pair of standalone touch interfaces. Each
Touch Zone has a dedicated set of outputs. GATE OUTPUT JACK(11,15), CV A OUTPUT
JACK(12,16), CV B OUTPUT JACK(13,17), Y-AXIS OUTPUT JACK(14,18). The Left and Right zone
outputs are always active in both Mono and Duo modes.
The GATE OUTPUT JACK(11,15) outputs a 6 volt, 13ms gate signal when a Touch Plate is pressed, a
sequence is advanced within the zone, or a change in the scan value is detected.
CV A OUTPUT JACK(12,16) outputs a voltage determined by the VOLTAGE PRESET KNOB A of the
active Touch Plate. The output range of the LEFT and RIGHT CV A OUTPUT JACK (12,16) is 0 to 5
volts.
CV B OUTPUT JACK(13,17) outputs a voltage determined by the VOLTAGE PRESET KNOB B of the
active Touch Plate. The output range of the LEFT and RIGHT CV B OUTPUT JACK (13,17) is 0 to 5
volts.
Y-AXIS OUTPUT JACK(14,18) outputs a voltage determined by the Y-axis touch location of the active
Touch Plate. The output range of the Y-AXIS OUTPUT JACK(14,18) is 0 to 5 volts.
567
123 4
8910 11 12 13 14 15 16 17 18 19 20 21 22
33 34 39
40 46 47
53 54
48 49
50 51 52 55 56 57 58 59
35 36 37
42 43 44
38
4541
30 31 32

10
Controller Modes
Mono and Duo Controller Modes
The Touch Controller operates in 2 different modes. Mono and Duo. Select the active mode by pressing
the MONO BUTTON (5) or DUO BUTTON (7) in the CHANNEL ANIMATOR SECTION (1).
Mono Mode
In Mono mode, the Touch Controllers operates like a single, monophonic 10 Touch Plate controller. The
ALL OUTPUT SECTION (4) combines the Left and Right Touch Zones into one section. The ALL GATE
OUTPUT (19) represents the state of the active Left or Right Touch Plate. The ALL Y-AXIS OUTPUT
(22) represents the Y-Axis value of the last Left or Right Touch Plate used. The ALL CV A OUTPUT
(20) outputs the VOLTAGE PRESET KNOB A value of the active Left or Right Touch Plate. The ALL
CV B OUTPUT (21) outputs the VOLTAGE PRESET KNOB B value of the active Left or Right Touch
Plate.
The ALL GATE OUTPUT JACK(19) outputs a 6 volt, 13ms gate signal when a Touch Plate is pressed,
a sequence is advanced, or a change in the scan value is detected.
ALL CV A OUTPUT JACK(20) outputs a voltage determined by the VOLTAGE PRESET KNOB A of the
active Touch Plate. The output range of the ALL CV A OUTPUT JACK (20) in Mono Mode is 0 to 5
volts.
ALL CV B OUTPUT JACK(21) outputs a voltage determined by the VOLTAGE PRESET KNOB B of the
active Touch Plate. The output range of the ALL CV B OUTPUT JACK (21) in Mono Mode is 0 to 5
volts.
Y-AXIS OUTPUT JACK(22) outputs a voltage determined by the Y-axis touch location of the active
Touch Plate. The output range of the ALL Y-AXIS OUTPUT JACK(22) is 0 to 5 volts.
Duo Mode
In Duo mode, the response of the ALL OUTPUT SECTION (4) is more complex. Like Mono mode, the
ALL GATE OUTPUT (19) represents the state of the last touched Left or Right Touch Plate and the ALL
Y-AXIS OUTPUT (22) represents the Y-Axis value of the last Left or Right Touch Plate used. However,
in Duo mode, the ALL CV A OUTPUT (20) outputs a SUM of the active Left VOLTAGE PRESET KNOB
A and the active Right VOLTAGE PRESET KNOB A. The ALL CV B OUTPUT (21) outputs a SUM of
the active Left VOLTAGE PRESET KNOB B and active Right VOLTAGE PRESET KNOB B. Summing
the Left and Right VOLTAGE PRESET KNOBs creates interesting potential for transposition and larger
CV output voltages.
The ALL GATE OUTPUT JACK(19) outputs a 6 volt, 13ms gate signal when a Touch Plate is pressed,
a sequence is advanced, or a change in the scan value is detected.
ALL CV A OUTPUT JACK(20) outputs a voltage determined by the sum of the LEFT and RIGHT
VOLTAGE PRESET KNOB A for the active Touch Plates. The output range of the ALL CV A OUTPUT
JACK (20) in Duo Mode is 0 to 10 volts.
ALL CV B OUTPUT JACK(21) outputs a voltage determined by the sum of the LEFT and RIGHT
VOLTAGE PRESET KNOB B for the active Touch Plates. The output range of the ALL CV B OUTPUT
JACK (21) in Duo Mode is 0 to 10 volts.
Y-AXIS OUTPUT JACK(22) outputs a voltage determined by the Y-axis touch location of the active
Touch Plate. The output range of the ALL Y-AXIS OUTPUT JACK(22) is 0 to 5 volts.

11
Mono Mode Sequencing
Mono Mode Sequencing
The Touch Controller can quickly create sequences using the Channel Animator section. A Mono
sequence utilizes the Left, Right, and All Output Jacks. The ALL OUTPUT SECTION is updated with
every active step. If the active step is in the Left Zone, the LEFT OUTPUT SECTION is updated, if the
active step is in the Right Zone, the RIGHT OUTPUT SECTION is updated.
Clocking a Sequence
The sequence is clocked using the STEP INPUT JACK (10). Sending a trigger or gate into the STEP
INPUT JACK (10) will advance the sequence 1 step.
Mono Sequence Clock Divider
A clock divider can be used to divide the incoming clock signal. The clock divider can be set to ÷1, ÷2,
÷3, ÷4, ÷5, ÷6, ÷7, ÷8, ÷9, or ÷10. Set the clock division by pressing and holding the RESET/REST
BUTTON then pressing the corresponding TOUCH PLATE.
The selected clock division is not saved when the Touch Controller is powered off. The default clock
division is ÷1.
Resetting a Sequence
The sequence can be reset to step 1 a few different ways. Pressing the RESET/REST BUTTON (6)
resets the sequence to step 1. Sending a trigger or gate signal into the RESET INPUT JACK (9) also
resets the sequence to step 1.

12
Mono Mode Sequencing Section (2 of 2)
Programming a Sequence
In Mono Mode, the Sequencer treats all 10 Touch Plates as a single monophonic touch interface. A
sequence is recorded by pressing and holding the MONO BUTTON (5). While the MONO BUTTON (5)
remains pressed, up to 64 steps can be added to the sequence by tapping the Touch Plates. The Y-
Axis is also recorded into the sequence during programming.
While the MONO BUTTON (5) remains pressed, a Touch Plate can be pressed multiple times to repeat
a step.
While the MONO BUTTON (5) remains pressed, the RESET/REST BUTTON (6) can be pressed to add
a rest step in the sequence.
The sequence begins cycling through the programmed steps as soon as the rst step is programmed
and a trigger or gate signal triggers the STEP INPUT JACK (10). To prevent the sequence from cycling
during programming, remove the clock from the STEP INPUT JACK (10) until programming is nished.
Clearing a Sequence
Press and release the MONO BUTTON (5) without touching a TOUCH PLATE to clear the sequence.
Switching from Mono to Duo clears the sequence.
Powering off the Touch Controller will clear the sequence.
Attention!
While a sequence is running, touching the TOUCH PLATES will not trigger the channel. Instead,
touching a TOUCH PLATE will re-record the Y-Axis. This allows the Y-Axis recorded into the sequence
to be modied without changing the selected channel sequence.
If the Touch Plates are not responding to touch, Press and release the MONO BUTTON (5) to clear the
active sequence and enable the Touch Plates.

13
Duo Mode Sequencing
Duo Mode Sequencing
The Touch Controller can quickly create 1 or 2 simultaneous sequences using the Channel Animator
section. The Left and Right Zones can be used to create 2 independent sequences. If the Left Zone
sequence is active, the LEFT OUTPUT SECTION is updated, if the Right Zone sequence is active, the
RIGHT OUTPUT SECTION is updated.
The ALL GATE OUTPUT (19) is triggered by an active step in the Left Zone or and active step in the
Right Zone. The ALL Y-AXIS OUTPUT (22) represents the Y-Axis value of the last Left or Right active
sequence step. The ALL CV A OUTPUT (20) outputs a SUM of the active Left VOLTAGE PRESET
KNOB A and the active Right VOLTAGE PRESET KNOB A. The ALL CV B OUTPUT (21) outputs a
SUM of the active Left VOLTAGE PRESET KNOB B and active Right VOLTAGE PRESET KNOB B.
Summing the Left and Right VOLTAGE PRESET KNOBs creates interesting potential for transposition
and larger CV output voltages.
Clocking a Sequence
The sequences are clocked using the STEP INPUT JACK (10). Sending a trigger or gate into the STEP
INPUT JACK (10) will advance the sequences 1 step.
Duo Sequence Clock Divider
A clock divider can be used to divide the incoming clock signal. The Left Zone Sequence and the Right
Zone Sequence can be divided independently. The clock divider for each zone can be set to ÷1, ÷2, ÷3,
÷4, or ÷8. Set the clock division by pressing and holding the RESET/REST BUTTON then pressing the
corresponding TOUCH PLATE in the Left or Right Zone.
The selected clock divisions are not saved when the Touch Controller is powered off. The default clock
division is ÷1.

14
Duo Mode Sequencing Section (2 of 2)
Resetting Both Sequences
The sequences can be reset to step 1 a few different ways. Pressing the RESET/REST BUTTON (6)
resets both sequences to step 1. Sending a trigger or gate signal into the RESET INPUT JACK (9) also
resets both sequences to step 1. The sequences can not be reset independently.
Programming the Sequences
In Duo Mode, the Left Zone and Right Zone work as independent sequencers. A sequence is recorded
by pressing and holding the DUO BUTTON (7). While the DUO BUTTON (7) remains pressed, up to 64
steps can be added to the Left and Right sequences by tapping the Touch Plates. The Y-Axis is also
recorded into the sequence during programming.
The Left and Right Sequences can be entered simultaneously or one at a time.
While the DUO BUTTON (7) remains pressed, a Touch Plate can be pressed multiple times to repeat a
step.
While the DUO BUTTON (7) remains pressed, the RESET/REST BUTTON (6) can be pressed to add a
rest step in the sequence with the last assigned step. If no steps have been programmed in the Left or
Right sequencers, the rest is assigned to the rst step of the Left sequencer.
The sequencers begin cycling independently through their programmed steps as soon as the rst step
of a sequence is programmed and a trigger or gate signal triggers the STEP INPUT JACK (10). To
prevent the sequencers from cycling during programming, remove the clock from the STEP INPUT
JACK (10) until programming is nished.
If only one sequence is active, the other Touch Plate Zone can be played manually.
Clearing a Sequence
Press and release the DUO BUTTON (7) without touching a Left or Right Touch Plate to clear the
sequences.
Switching from Duo to Mono clears the sequences.
Powering off the Touch Controller will clear the sequences.
Attention!
While the Left and/or Right sequencers are running, touching their Touch Plates will not trigger the
channel. Instead, touching a TOUCH PLATE will re-record the Left or Right Y-Axis. This allows the Y-
Axis recorded into the sequence to be modied without changing the selected channel sequence.
If the Touch Plates are not responding to touch, Press and release the DUO BUTTON (7) to clear the
active sequences and enable the Left and Right Touch Plates.

15
Scan Mode
The r
Scan Mode Active Channel Sequencing
The SCAN INPUT JACK (8) of the Touch Controller accepts a 0v to 5v control voltage signal and sets
the active channel based on the incoming voltage. The Scan Input updates the active channel when the
incoming voltage changes.
In Mono Mode, the Scan input spreads the 0 to 5v range across all 10 channels. In Duo Mode the Scan
input spreads the 0v to 5v range across both the Left and Right sides so each side responds the the full
0v to 5v range.

16
More Information
Eurorack Specs
Panel size: 38hp.
Module depth: 35mm.
Power consumption: +12v 165mA, -12v 95mA. Does not require +5v. Reversed power
polarity protection. Due to the complexity of this module, it requires a signicant amount of
power. Please use a clean, high quality power source for optimum performance.
Warranty
For a period of one year after the date of original purchase, the Lifeforms Touch Controller
manufactured by Pittsburgh Modular Synthesizers LLC, is warranted to function properly
and be free of defects in materials and workmanship. Should a factory installed hardware
fail during the warranty period, contact Pittsburgh Modular Synthesizers LLC. We will repair
it (or at our option, replace it) at no charge, and pay the cost of shipping it back to you. This
warranty is void if in our opinion the Lifeforms Touch Controller has been damaged by
accident, mishandled, altered, improperly serviced, or repaired by the customer where such
treatment has affected its performance or reliability. This includes but is not limited to
damage related to incorrectly attaching power ribbon cables. In the event of such
misuse/abuse by the customer, costs for repairs plus two-way shipping costs will be borne
by the customer. Products found defective should be returned to the factory carefully
packed, as the customer will be responsible for freight damage. Incidental or consequential
damages or costs incurred as a result of product malfunction are not the responsibility of
Pittsburgh Modular Synthesizers LLC.
Service and Contact Information
Please contact us for service or other information related to the Lifeforms Touch Controller
or any other Pittsburgh Modular product.
www.pittsburghmodular.com/contact

Pittsburgh Modular Synthesizers
Table of contents
Popular Controllers manuals by other brands

HySecurity
HySecurity StrongArm M30 Programming & operation manual

Sky Master
Sky Master NLC-751 user manual

Hobby King
Hobby King 30A Boat manual

Aqua Medic
Aqua Medic aquaniveau 77113 Operation manual

Oriental motor
Oriental motor DRS Series operating manual

Oriental motor
Oriental motor DRLII Series operating manual

i-MO
i-MO i3 User Start-up Guide

TriStar
TriStar TS-MPPT-30 Installation, operation and maintenance manual

Astral Pool
Astral Pool IGNIA LIGHT DMX pro quick start guide

Hobby-Wing
Hobby-Wing XERUN XR10 STOCK SPEC 1S user manual

Data Video
Data Video MCU-100 quick start guide

Meanwell
Meanwell KAA-8R Series instruction manual