Redline RDL-3000 SC Instruction sheet

Virtual Fiber™
Outdoor Wireless TCP/IP Transport
70-00159-02-00 Proprietary Redline Communications © 2014 Page 1of 59 July 18, 2014
RDL-3000
Universal Wireless Transport™
(UWT™) System
Ellipse TMA Sector Controller
Multi-Sector System
Installation Guidelines
1Important Notices...................................................................8
2System Features...................................................................14
3Materials................................................................................33
4Site Survey............................................................................34
5Site Preparation....................................................................39
6Assemble Kits.......................................................................42
7Install Equipment..................................................................46
8Reference..............................................................................53

RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
70-00159-02-00 Proprietary Redline Communications © 2014 Page 2of 59 July 18, 2014
Copyright Information
All rights reserved July 18, 2014. The information in this document is proprietary to
Redline Communications Inc. This document may not in whole or in part be copied,
reproduced, or reduced to any medium without prior consent, in writing, from Redline
Communications Incorporated.
Contact Information:
Redline Communications Inc.
302 Town Centre Blvd.
Markham, ON
Canada L3R 0E8
Web site:
www.rdlcom.com
Email:Inquiries: info@rdlcom.com
Support: support@rdlcom.com
Training: training@rdlcom.com
Document Control:
70-00159-02-00-RDL-3000_Ellipse_TMA_SC_Installation_Guide-20140718a.doc
Disclaimer
The statements, configurations, technical data, and recommendations in this document
are believed to be accurate and reliable, but are presented without express or implied
warranty. Additionally, Redline makes no representations or warranties, either expressed
or implied, regarding the contents of this product. Redline Communications shall not be
liable for any misuse regarding this product. The information in this document is subject
to change without notice. No part of this document shall be deemed to be part of any
warranty or contract unless specifically referenced to be part of such warranty or
contract within this document.
Software Versions
This manual describes operation using software release v2.27 and may include features
that are different or unavailable in previous software releases.
Some Ellipse TMA Sector Controller features are controlled by options keys and are
available only on specific revisions of hardware systems. Refer to the individual product
Release Notes for information about required software and availability of features.

RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
70-00159-02-00 Proprietary Redline Communications © 2014 Page 3of 59 July 18, 2014
Revision Log
Date
Item
Description of Changes
20140626
All
First draft

RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
70-00159-02-00 Proprietary Redline Communications © 2014 Page 4of 59 July 18, 2014
TABLE OF CONTENTS
1Important Notices...................................................................8
1.1 Important Deployment Information...................................................................8
1.2 Service & Safety.................................................................................................8
Safety Warnings.............................................................................................8
General Warnings..........................................................................................8
Warning Symbols...........................................................................................8
1.3 Installation Safety..............................................................................................9
Professional Installation / Installations Professionnel .....................................9
Safety Precautions.........................................................................................9
Electrocution Hazard / Risque D’électrocution................................................9
Radio Frequency Safety / Sécurité des Fréquences Radio ..........................10
Personal Safety............................................................................................10
Electrical Safety ...........................................................................................10
Electrical Safety Compliance / Conformité à la Sécurité Electrique ..............10
UL Information .............................................................................................11
Lightning Protection / Protection Contre la Foudre.......................................11
1.4 WEEE Product Return Process.......................................................................12
1.5 Service & Warranty Information......................................................................13
2System Features...................................................................14
2.1 Ellipse TMA Sector Controller.........................................................................18
Ethernet/Power Port.....................................................................................18
TMA-SYNC Port...........................................................................................18
GPS Antenna Port........................................................................................19
Ground Lug..................................................................................................19
RF Ports.......................................................................................................19
2.2 TMA Tower Amplifier.......................................................................................20
RF In Ports...................................................................................................20
TMA-SYNC Port...........................................................................................20
Power Port...................................................................................................21
Ground Lug..................................................................................................21
RF Out Ports................................................................................................21
2.3 Sector Antenna ................................................................................................22
2.4 Antenna RF Cables..........................................................................................24
2.5 Antenna RF Jumper Cables ............................................................................24
2.6 Ethernet Cables (Circular Connector) ............................................................25
2.7 PoE Power Injector ..........................................................................................26
2.8 RF Splitter.........................................................................................................28
2.9 Synchronization Kit .........................................................................................31
2.10 GPS Antenna Kit..............................................................................................32

RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
70-00159-02-00 Proprietary Redline Communications © 2014 Page 5of 59 July 18, 2014
3Materials................................................................................33
4Site Survey............................................................................34
4.1 General Layout Options ..................................................................................34
4.2 Survey for RF Access to Sector Antennas.....................................................35
4.3 Survey for GPS Satellites................................................................................36
4.4 Survey Power Source......................................................................................37
4.5 Survey Network (Ethernet) Connection..........................................................38
5Site Preparation....................................................................39
5.1 Mast for Ellipse TMA Sector Controller..........................................................39
5.2 Mast for Sector Antenna..................................................................................40
5.3 Mast for GPS Antenna.....................................................................................41
6Assemble Kits.......................................................................42
6.1 Assemble Sector Controller with RF Splitter.................................................42
6.2 Assemble Sector Antenna with TMA Amplifier..............................................44
Wiring the TMA Tower Amplifier Detail View................................................45
7Install Equipment..................................................................46
7.1 Mount Sector Antenna on Mast ......................................................................47
Mounting Detail View ...................................................................................48
7.2 Tower Cabling..................................................................................................49
7.3 Mount GPS Antenna System...........................................................................50
7.4 Assemble GPS Antenna Kit.............................................................................50
7.5 Mount Sector Controller (with RF Splitter).....................................................51
7.6 Sector Controller Wiring Overview.................................................................52
8Reference..............................................................................53
8.1 Weatherproofing Procedures..........................................................................53
8.2 General Grounding Guidelines.......................................................................55
8.2.1 Grounding.......................................................................................................55
8.2.2 Surge Protection.............................................................................................56
8.2.3 Air Terminal Mounting for Tower and Pole Deployments.................................57
8.2.4 Protecting Cables from Abrasion and Temperature.........................................57
LIST OF TABLES
Table 1: Notice - Electrical Safety Specifications...........................................................11
Table 2: Avis - Spécifications de sécurité électrique......................................................11
Table 3: Features- Ellipse TMA Sector Controller System Components........................17
Table 4: Features - PoE Power Injector Ports................................................................22

RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
70-00159-02-00 Proprietary Redline Communications © 2014 Page 6of 59 July 18, 2014
Table 5: Features - PoE Power Injector Ports................................................................26
Table 6: Materials - Installer Supplied Materials ............................................................33
Table 7: Survey: Power Cable.......................................................................................37
LIST OF FIGURES
Figure 1: Notice - WEEE Logo.......................................................................................12
Figure 2: Features: Ellipse TMA Sector Controller System Overview ............................14
Figure 3: Features: Ellipse TMA Sector Controller Simplified Block Diagram.................15
Figure 4: Features: Ellipse TMA Sector Controller System Components.......................16
Figure 5: Features: - Ellipse TMA Ports.........................................................................18
Figure 6: Features: Ellipse TMA RF Ports (Top View of Radio) .....................................19
Figure 7: Features: Ellipse TMA Sector Controller Dimensions .....................................19
Figure 8: Features: TMA RF Tower Amplifier RF IN, Sync and Power In.......................20
Figure 9: Features: TMA RF Tower Amplifier RF IN, Sync and Power In.......................20
Figure 10: Features: Ellipse TMA RF Ports (Top View of Radio) ...................................21
Figure 11: Features: Ellipse TMA Power Amplifier Dimensions.....................................21
Figure 12: Features: UHF Sector Antenna Ports ...........................................................22
Figure 13: Features: Sector Antenna Dimensions .........................................................23
Figure 14: Features: RF Antenna Cables - SC Splitter to Tower Amp ...........................24
Figure 15: Features: RF Jumper Cables - Antenna to TMA Tower Amplifier..................24
Figure 16: Features: Ethernet Data Cable.....................................................................25
Figure 17: Features - Ethernet PoE - Indoor Power Module Pinout ...............................26
Figure 18: Features: PoE Power Injector Mounting Dimensions....................................27
Figure 19: Features: RF Splitter-Combiner....................................................................28
Figure 20: Features: RF Splitter Dimensions.................................................................28
Figure 21: Features: Wireless Terminal/Splitter Mounting Bracket Dimensions.............29
Figure 22: Features - Ethernet Line Protection Ports.....................................................30
Figure 23: Features - Ethernet Line Protection Device Dimensions...............................30
Figure 24: Features: Synchronization Kit.......................................................................31
Figure 25: Features: Synchronization Kit with Terminator..............................................31
Figure 26: Features: GPS Antenna Kit...........................................................................32
Figure 27: Survey: Ellipse TMA Sector Controller General Layout.................................34
Figure 28: Survey: UHF Antenna...................................................................................35
Figure 29: Survey: GPS Antenna...................................................................................36
Figure 30: Survey: Power Cable Routing.......................................................................37
Figure 31: Survey: Ethernet Cable Routing ...................................................................38
Figure 32: Preparation - Ellipse TMA Sector Controller Mast Requirements..................39
Figure 33: Preparation - Sector Antenna with TMA Amplifier Mast Requirements .........40
Figure 34: Preparation - GPS Antenna Mast Requirements...........................................41
Figure 35: Assembly- Sector Controller with RF Splitter................................................42
Figure 36: Assembly - Mounting the Ellipse TMA Base Station (with splitters)...............43
Figure 37: Assembly: Mounting Tower Amplifier to the Sector Antenna.........................44
Figure 38: Assembly: Tower Amplifier Wiring ................................................................45
Figure 39: Sector Controller: Dual Polarity UHF Panel Antenna: Mounting Detail..........45
Figure 40: Installation TMA Sector Controller General Layout .......................................46
Figure 41: Installation: Mounting the Sector Antenna.....................................................47
Figure 42: Installation: Mounting the Sector Antenna.....................................................48

RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
70-00159-02-00 Proprietary Redline Communications © 2014 Page 7of 59 July 18, 2014
Figure 43: Installation: Sector Antenna / Amplifier Wiring ..............................................49
Figure 44: Assembly: - GPS Antenna Kit.......................................................................50
Figure 45: Installation: Mounting Sector Controller and Splitter .....................................51
Figure 46: Installation: Ellipse TMA Sector Controller Wiring Overview .........................52
Figure 47: Procedures - RF Port - Weatherproofing Pt-1...............................................53
Figure 48: Procedures - RF Port - Weatherproofing Pt-2...............................................54
Figure 49: Procedures - RF Port - Weatherproofing Pt-3...............................................54
Figure 50: Procedures - RF Port - Weatherproofing Pt-4...............................................54
Figure 51: Procedures - Installing Surge Protection.......................................................56
Figure 52: Procedures - Air Terminal for Tower and Pole Deployments.........................57
Figure 53: Procedures - Cable Protection - Spiroband...................................................57

RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
70-00159-02-00 Proprietary Redline Communications © 2014 Page 8of 59 July 18, 2014
1 Important Notices
1.1 Important Deployment Information
IMPORTANT: Refer to the RDL-3000 Family User Manual for detailed regulatory
information. Refer to this document before deploying and powering RDL-3000 family
systems in the field.
1.2 Service & Safety
Safety Warnings
WARNING - MICROWAVE TRANSMISSIONS: Do not operate or work in close
proximity to this equipment without first having proper training or knowledge of
microwave radio operation.
Read this manual and follow all operating and safety instructions.
Installation of the system must be contracted to a professional installer.
Keep all product information for future reference.
The power requirements are indicated on the product-marking label. Do not exceed
the described limits.
The unit must not be located near power lines or other electrical power circuits.
Disconnect the power before cleaning, or when the unit is not be in-use for an
extended period.
The system must be properly grounded to protect against power surges and
accumulated static electricity. The user is responsible for installing this device in
accordance with the local electrical codes: correct installation procedures for
grounding the unit, mast, lead-in wire and discharge unit, location of discharge unit,
size of grounding conductors and connection requirements for grounding electrodes.
General Warnings
Redline recommendations for maximum safety include the following:
Do not operate microwave equipment without first having proper training or
knowledge of microwave radio operation.
Do not operate the microwave equipment without an appropriate antenna port
termination, or antenna.
Do not look into or stand in front of an antenna.
Do not swing or aim an antenna at nearby persons while the equipment is operating.
Check to ensure that the area around the antenna is clear of personnel prior to
turning the transmitter on.
In locations where other antennas are installed, do not proceed with an installation
without first determining the RF/µW exposure risk. Where necessary have the
relevant transmitters turned off or wear a protective suit for the duration of the
installation.
Warning Symbols
These symbols may be encountered during installation or troubleshooting. These
warning symbols mean danger. Bodily injury may result if you are not aware of the safety
hazards involved in working with electrical equipment and radio transmitters. Familiarize
yourself with standard safety practices before continuing.
Chapter 1

RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
70-00159-02-00 Proprietary Redline Communications © 2014 Page 9of 59 July 18, 2014
WARNING
ELECTRO-MAGNETIC
RADIATION
WARNING
HIGH VOLTAGE
WARNING
HOT SURFACE
DO NOT TOUCH
1.3 Installation Safety
Professional Installation / Installations Professionnel
Redline RDL-3000 systems require professional installation. The user is responsible to
ensure all building and safety codes are met and the installation is complete and
secure.
The RDL-3000 system shall be installed according to local Electrical Safety Codes.
For Canadian installations, the entire equipment installation must comply with the
Canadian Electrical Code. For installations in the United States, the entire equipment
installation must be in accordance with Article 810 of the United States National
Electrical Code.
Les appareils RDL-3000 de Redline doivent être installés par un personnel
professionnel. Le personnel responsable doit s’assurer que l’installation est bien
achevée, et qu’elle répond aux exigences de tous les codes de sécurité.
Le RDL-3000 doit être installé conformément aux codes locaux de sécurité électrique.
Pour les installations Canadiennes, l'installation de l'équipement au complet doit se
conformer au Code Canadien de l'électricité. Pour les installations aux États-Unis,
l'installation de l'équipement au complet doit être en conformité avec l'article 810 du
Code des États-Unis National Electrical.
Safety Precautions
Installation and service must be done by personnel having technical training and
experience necessary to be aware of hazards during installation and/or service of
outdoors RF equipment. The installation and/or service must be done using procedures
designed to minimize any danger to technical personnel or any other person.
Use safety devices when working on or around the mast. Be aware of the risk of falling
objects. Use provided safety catches when hoisting antennas and radios.
Do not use any components (screws, nuts, etc.) other than those delivered together with
the Redline microwave radio equipment or those recommended by Redline.
Electrocution Hazard / Risque D’électrocution
Warning to Service Personnel
Do not install Redline products near any type of power line. Should the antenna or
related hardware come in contact with power lines, severe bodily harm or death could
result!

RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
70-00159-02-00 Proprietary Redline Communications © 2014 Page 10 of 59 July 18, 2014
Attention au personnel du service
Ne pas installer les produits Redline près n'importe quel type de ligne électrique. Si votre
antenne ou du matériel connexe entrer en contact avec des lignes électriques, des
blessures graves ou la mort pourraient en résulter!
Radio Frequency Safety / Sécurité des Fréquences Radio
The installer of this radio equipment must ensure that the antenna is located or pointed
such that the antenna does not emit RF fields in excess of the general population limits
as defined by:
FCC CFR 47, Part 2.1091
http://www.gpo.gov/fdsys/pkg/CFR-2009-title47-vol1/pdf/CFR-2009-title47-vol1-sec2-
1091.pdf
FCC OET Bulletin 65, Radio frequency radiation exposure evaluation for fixed
devices
http://transition.fcc.gov/Bureaus/Engineering_Technology/Documents/bulletins/oet65
/oet65c.pdf
Health Canada limits for the general population; consult Safety Code 6, obtainable
from Health Canada’s website:
http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct-eng.php
Santé Canada limite pour la population générale; consulter le Code de sécurité 6,
disponible sur le site Web de Santé Canada:
http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct-fra.php .
Personal Safety
WARNING: HOT SURFACE. DO NOT TOUCH.
The RDL-3000 Ellipse TMA Sector Controller system is rated for operation at extreme
ambient temperatures. When operating in high temperature conditions, the chassis
surface area can be higher than the ambient temperature and personal thermal
protection should be employed for any maintenance or inspection activity.
Electrical Safety
The equipment meets the requirements for class I EN 60950-1 (protection against
electric shock).
All external circuits are TNV-1 (as defined in EN 60950-1).
All equipment must be grounded before the power cable is connected.
For electrical safety the DC power supply shall have reinforced insulation to the
mains supply.
Electrical Safety Compliance / Conformité à la Sécurité Electrique
The RDL-3000 system hardware has been tested for compliance to the electrical safety
specifications listed in the following table.

RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
70-00159-02-00 Proprietary Redline Communications © 2014 Page 11 of 59 July 18, 2014
Table 1: Notice - Electrical Safety Specifications
Class I
EN 60950-1
All External Circuits
TNV-1 as defined in EN 60950-1
All equipment must be grounded
Le RDL-3000 du matériel a été testé pour la conformité aux normes de sécurité
électriques indiquées dans le tableau suivant:
Table 2: Avis - Spécifications de sécurité électrique
Classe I
EN 60950-1
Tous les circuits externes
TRT-1 tel que défini dans la norme EN
60950-1
Tous les équipements doivent être mis à la terre
UL Information
The suitability of the supplied Ethernet cable is subject to the approval of Authority
Having Jurisdiction and must comply with the local electrical code.
The equipment must be properly grounded according with NEC and other local
safety code and building code requirements.
Reminder to all the BWA system installers: Attention to Section 820-40 of the NEC
which provides guidelines for proper grounding and, in particular, specifies that the
cable ground shall be connected to the grounding system of the building, as close to
the point of cable entry as is practical.
RDL-3000 system must be installed in compliance with relevant articles in National
Electrical Code-NEC (and equivalent Canadian Code-CEC) including referenced
articles 725, 800 and 810 in NEC.
RF coaxial cable connecting an antenna to the RDL-3000 system must comply with
the local electrical code.
To meet the over-voltage safety requirements on the telecommunications cables, a
minimum 26 AWG telecommunication line cord must be used.
Pour être en conformance avec les exigences finies de sûreté de sur-tension sur les
câbles de télécommunications un fil de télécommunication ayant un calibre minimum
de 26 AWG doit être utilisé.
Lightning Protection / Protection Contre la Foudre
When installed, this equipment is to be connected to a Lightning/Surge Protection
Device that meets all applicable national safety requirements. Before Ethernet cables
enter buildings, voltages shall be clamped down to SELV by approved type primary
protectors.
WARNING: The information provide in this user manual consists of general
recommendations for installation the system equipment. The wireless equipment must
be installed by a qualified professional installer who is knowledgeable of the
requirements of installing outdoor radio equipment and follows local and national codes
for electrical grounding and safety. Failure to meet safety requirements and/or use of
non-standard practices and procedures may result in personal injury and/or damage to
equipment.
The system must be properly grounded to protect against power surges and
accumulated static electricity. The user is responsible to install this device in accordance
with the local electrical codes: correct installation procedures for grounding the unit,
mast, lead-in wire and discharge unit, location of discharge unit, size of grounding
conductors and connection requirements for grounding electrodes.

RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
70-00159-02-00 Proprietary Redline Communications © 2014 Page 12 of 59 July 18, 2014
All outdoor wireless equipment is susceptible to surge damage from a direct hit or
current induced from a near strike. A direct lightning strike may cause serious damage
even if recommended guidelines are followed. Installing surge protection and following
grounding practices detailed in local and national electrical codes can minimize
equipment damage, service outages, and chance of serious injury.
The major reasons for surge damage can be summarized as:
Poorly grounded antenna sites
Improperly installed surge protection equipment
A lighting protection system provides a means by which the energy may enter earth
without passing through and causing damage to parts of a structure. A good grounding
system disperses most of the surge energy from a lightning strike away from the building
and equipment. Improperly grounded connections are a source of noise that can cause
malfunctions in sensitive equipment. The remaining energy on the Ethernet cable shield
and conductors can be directed safely to ground by installing a surge arrestor in series
with the cable. A surge protection system does not prevent lightning strikes, but protects
equipment by providing a low resistance path for the discharge of energy safely to
ground. If surge protection is required for the system, the following general industry
practices are provided as a guideline only:
The AC source ground for the indoor power adapter should be connected to the
building grounding system.
Install a surge arrestor in series with the Ethernet cable at the point of entry to the
building. The grounding wire should be connected to the same termination point
used for the tower or mast.
Provide direct grounding connections from the RDL-3000 system, the mounting
bracket, and the antenna to the common building ground bus. Use the grounding
screws provided for terminating the ground wires.
L’installation exige aussi que l’appareil soit branché à un parafoudre qui répond à
toutes les normes nationales de sécurité.
1.4 WEEE Product Return Process
In accordance with the WEEE (Waste from Electrical and Electronic Equipment)
directive, 2002/96/EC, Redline Communications equipment is marked with the logo
shown below. The WEEE directive seeks to increase recycling and re-use of electrical
and electronic equipment. This symbol indicates that this product should not be disposed
of as part of the local municipal waste program. Contact the local sales representative
for additional information.
Figure 1: Notice - WEEE Logo

RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
70-00159-02-00 Proprietary Redline Communications © 2014 Page 13 of 59 July 18, 2014
1.5 Service & Warranty Information
Refer all repairs to qualified Service personnel. Removing the cover panel or
modifying any part of this device will void the factory warranty.
Locate the serial numbers and record these for future reference. Use the space
below to affix serial number stickers. Also, record the MAC address identified on the
unit product label.
Redline does not endorse or support the use of outdoor cable assemblies: i) not
supplied by Redline, ii) third-party products that do not meet Redline's cable and
connector assembly specifications, or iii) cables not installed and weatherproofed as
specified in the RDL-3000 Installation Guidelines manual for each product model.
Refer to the Redline Limited Standard Warranty and RedCare Service agreements.

RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
70-00159-02-00 Proprietary Redline Communications © 2014 Page 14 of 59 July 18, 2014
2 System Features
The RDL-3000 Ellipse TMA wireless sector controller is designed and manufactured by
Redline Communications, a world leader in design and production of outdoor wireless
TCP/IP transport for mission critical applications.
Figure 2: Features: Ellipse TMA Sector Controller System Overview
Chapter 2

RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
70-00159-02-00 Proprietary Redline Communications © 2014 Page 15 of 59 July 18, 2014
Figure 3: Features: Ellipse TMA Sector Controller Simplified Block Diagram

RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
70-00159-02-00 Proprietary Redline Communications © 2014 Page 16 of 59 July 18, 2014
Figure 4: Features: Ellipse TMA Sector Controller System Components

RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
70-00159-02-00 Proprietary Redline Communications © 2014 Page 17 of 59 July 18, 2014
Table 3: Features- Ellipse TMA Sector Controller System Components
#
Item
Description
1
Ellipse TMA
Sector Controller
Ellipse TMA wireless sector controller. Supports multiple tower-
mounted powered antennas.
2
MIMO sectoral
antenna
Sector antenna. 470-698 MHz, 11.5dBi, 1.5 m (5ft), 90 degree,
dual-polarity, 2xN (m) with mounting hardware
3
Industrial Ethernet
Cable
Outdoor Ethernet cable pre-terminated with 11-position circular
connector socket and RJ-45 shielded plug.
Cable CAT5e 90m (300 ft) double shielded outdoor-rated
industrial.
4
Surge Arrestor
Power Surge Arrestor RJ-45 outdoor 2x RJ-45 sockets
5
GPS Antenna Kit
Kit includes active-type GPS antenna TNC/F, 6 m (20 ft) antenna
cable LMR195 (2x TNC/M), antenna bracket arm, and mounting
hardware for 45 -115 mm (1.75 - 4.5 in) mast pipe.
6
Power Cord
Cable Power AC UK Shielded 1.2 m (6 ft)
7
PoE Power Injector
Power Supply AC-DC POE Midspan Univ-AC 10/100/1000BaseT
30W 802.3at 2xRJ45 Shelf-Wall MNT
8
Options Keys
The supplied Options Keys must be entered to enable operation of
the Ellipse TMA sector controller.
9
TMA Tower
Amplifier Kit
a) TMA RF tower amplifier. Operation synchronized using TMA
sync cable from Ellipse TMA sector controller.
b) Cable Splitter-Combiner Wilkinson 1-4 Outdoor-rated N-(f) with
2x 50-ohm terminations
c) Mount bracket kit, splitter, 4_way, radio, SSTL
d) Cable Assembly, N-M to TNC-M, 25'
e) Cable Assembly, N-M to N-M, RA, 6 in
f) SYNC CABLE KIT, RDL-3000, (CABLE ASSY 20FT TNC-m to
TNC-m & TNC T f-m-f), w/TNC with terminator
g) SYNC CABLE KIT, RDL-3000, (CABLE ASSY 20FT TNC-m to
TNC-m & TNC T f-m-f)

RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
70-00159-02-00 Proprietary Redline Communications © 2014 Page 18 of 59 July 18, 2014
2.1 Ellipse TMA Sector Controller
Figure 5: Features: - Ellipse TMA Ports
Ethernet/Power Port
The Ethernet port (RJ-45 / F connector) receives DC power and provides Ethernet
connectivity with the local network. The Ethernet port connects to the PoE adapter using
a weatherproof CAT-5e Ethernet cable.
TMA-SYNC Port
The TMA-Sync port (TNC / F connector) is used to synchronize operation of the remote
TMA SYNC RF Tower Amplifier units.
The TMA-SYNC ports of all units must be interconnected using LMR-195 (or equivalent)
coaxial cable terminated with TNC / M connectors. Use TNC Tee adapters to connect
units in a daisy-chain configuration.
Important: Multiple Tower Amplifiers can be synchronized using up to 46 m (~150 ft).of
interconnecting synchronization cable.

RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
70-00159-02-00 Proprietary Redline Communications © 2014 Page 19 of 59 July 18, 2014
GPS Antenna Port
The GPS antenna port (TNC / F connector) conducts RF signals from an attached GPS
antenna system. This port is provided only on units factory-equipped with GPS
hardware. The system supports passive and active GPS antenna types. The GPS
antenna can be located up to 46 m (~150 ft) of high quality antenna cable.
A factory-installed protective weatherproof plastic cap is installed on the GPS antenna
port. The port must be weatherproofed if this cap is removed.
Notes:
1. The GPS antenna is active type.
2. The GPS module does not set the internal date/time clock.
Ground Lug
A ground-lug is provided on the Ellipse TMA chassis. Use this connection to
terminate a grounding wire. All Ellipse TMA systems must be properly grounded to
protect against power surges and accumulated static electricity.
RF Ports
The two RF ports (N-type F connectors) conduct RF signals between the Ellipse TMA
and the antenna system (ordered separately). The Ellipse TMA can be operated using a
SISO (single antenna) or MIMO (multiple antenna) system. RF jumper cables are
included with Redline mounting kits.
Figure 6: Features: Ellipse TMA RF Ports (Top View of Radio)
Figure 7: Features: Ellipse TMA Sector Controller Dimensions

RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
70-00159-02-00 Proprietary Redline Communications © 2014 Page 20 of 59 July 18, 2014
2.2 TMA Tower Amplifier
The tower amplifier is mounted on the sector antenna. This provides extra RF gain and
additional flexibility in location for mounting the sector antennas. The transmit/receive
operations are synchronized using the TMA synchronization signal.
Figure 8: Features: TMA RF Tower Amplifier RF IN, Sync and Power In
Figure 9: Features: TMA RF Tower Amplifier RF IN, Sync and Power In
RF In Ports
The RF-1 and RF-2 input ports (TNC type F connectors) conduct RF signals between
the Ellipse TMA and the TMA RF Tower Amplifier system.
TMA-SYNC Port
The TMA-Sync port (TNC / F connector) is used to synchronize operation of the remote
TMA SYNC RF Tower Amplifier units.
The TMA-SYNC ports of all units must be interconnected using LMR-195 (or equivalent)
coaxial cable terminated with TNC / M connectors. Use TNC Tee adapters to connect
units in a daisy-chain configuration.
Important: Multiple RF Amplifier units can be synchronized using up to 46 m (~150 ft).of
interconnecting synchronization cable.
Other manuals for RDL-3000 SC
6
Table of contents
Other Redline Controllers manuals
Popular Controllers manuals by other brands

Mitsubishi Electric
Mitsubishi Electric MELSEC iQ-F Series user manual

Spirax Sarco
Spirax Sarco LCR2251 Installation and maintenance instructions

BP Hobbies
BP Hobbies Cheetah 60A quick start guide

Ametek
Ametek Gemco 952CP Ram-Set Installation and maintenance manual

Siemens
Siemens GD Series Mounting instructions

MSA
MSA GasGard XL operating manual