D.H
Please visit
www.pixeltechnolgies.com.au
for warranty disclaimer, mechanical drawings and serviceable parts.
MANUFACTURER: E5405
MODEL: EM-181Mu
Proudly Developed & Manufactured in Australia
pixeltechnologies.com.au
COPYRIGHT 2020
PHONE LINE
L1 L2
OUTPUT DC IN
O-2 O-1 I-2 I-1 0V V+
INPUT
50mA
DT V+ SIG 0V
PIT
DT V+ SIG 0V
CAR
DT V+ SIG 0V
MR
DT V+ SIG 0V
AUX
SD CARD
STATUS
FAULT
IN-USE
BATTERY
(RED)
(GREEN)
(YELLOW)
(BLUE)
u
LED Indicaon
Staon Bus
Data & V+ Signal & 0V + (Shield)
Recommended Cabling:
Shielded Twisted Pair
Belden 8723 or equivalent
Keep away from
high voltage wiring
& DC & VF drives
!
For improved noise immunity
I-1
I-2
O-1
O-2
Alarm Filter (Master)
*Li Breakdown Report
Output 1
Output 2
I/O Interface Port
!Outputs: Open-Collector
Max Sink Current: 50mA (max)
Both outputs 1 & 2 are configurable
*Li Breakdown Report via RPMS (Monitoring Service)
Please reference Advanced Programming Guide
for further details.
Interface to li intercom staons
SD Card
▪ Call Voice Recording
▪ Easy System Setup
PN: CT-18V/2A
Incoming Call
Outgoing Call
Baery Mode
No Baery
No Phone Line
Fault
(Red)
Baery
(Yellow)
In-Use
(Green)
Idle
Status
(Blue)
1 Second
To replace simply remove the two case screws. Push back the
two PCB board retainer tabs to remove circuit board allowing
access to internal baery.
Standby: 4 Hours
Talk Time: 2 Hours
Pixel replacement PN: SR-12V-0.8AH
Baery Replacement
Baery replacement required 3 years from install date.
FXO Interface (Phone Line)
PABX System, PSTN, NBN or Wireless Cellular Gateway
To access the EM-181Mu
Advanced Programming
Guide on your tablet
or smart phone
!In order to page another staon you must return back
to the EM-181Mu master controller by entering;
You will now be ready to connect to another staon.
# #
When dialling into the system, and there are previous alarms
logs, your call will be automacally connected to the last staon
which raised an alarm.
Dialling into the System
c
Please reference Advanced Programming Guide
for further details.
All outgoing alarm calls are registered by the system.
The Alarm LED at the staons will remain ON to indicate an alarm
had been made.
To RESET the Alarm Logs and LED indicators at all staon, ensure you are
connected to the EM-181Mu master controller by entering # #, then enter
the following sequence;
#1234*
Alarm Logs
EN81-28:2018 compliant
The system will respond with “sequence accepted”.
Enter the Staon ID number from your remote handset
MR
TOP
CAR
PIT
0
1
2
3
SPARE
AUX-A
AUX-B
AUX-C
4
5
6
7
Page ALL 9
To Page a Staon
When connected, the system will playback the staon name.
SCAN ME
!
Please connect a power
diode (1N4004) in series
with V+ when powering
from a li controllers PSU.