Plasma Ions PS-500T2 User manual

Plasma Air Sterilizer
(Please read the instructions before use)
PS-500T2
Plasma Ions
Warranty Card
(Please keep it properly)
Product
Name
Purchase
Time
Product
Number
Contact
Number
Customer
information
Name/company
contact address
Sales company stamp:
(二)Perforated installation:
1.Mark the location of
the hole punch.
2.Percussion drilling,
hole diameter 6mm.
3.Put the rubber plug.
Label position Punch Expansion rubber plug
4.Use the key to open the
front cover of the product.
5.Use a screwdriver to
fix the screws.
6.Plug in the power adapter
and connect the power input.
Open the front cover Power on
Screw on
1. Install according to the actual environment.
2. Adjust the number of ions according to the actual environment.
3. Connect connect power supply and turn on, the main switch is on the side of the
machine, open The switch indicator lights up, indicating that the machine has entered
operation and the fan is working. Air volume, 220m³/h.
Installation Notes
500mm
340mm
60mm
235mm
420mm
Hole sizeProduct Size
(⼀)Product Size:
扭动锁匙
It is suitable for use in places where buses, trains, coaches, and long-distance buses are prone to
odor and bacteria.
Use and characteristics
Plasma generator
Power and other
indicator signals
are not lit
Check if the power cords securely inserted into the unit and
it is loose. Check the power outlet for power supply and check
the 1.0 mA standard (certified) fuse
Under normal circumstances, there is a slight current sound
and black There is a faint blue light in the dark. If found.The
ion tube bursts and the ion tube needs to be replaced.0.5 mA
standard (with certified) fuse.
Please send the following to the company's designated
maintenance department for repairs.
1. The problem cannot be solved as described above.
2. Foreign matter or moisture enters, and abnormal conditions occur.
Fault condition Processing check
Fault check
Precautions
This machine is designed for only indoor general using. Do not place it open-air or high
temperature place.
Before operating the machine, make sure the power cord is firmly plugged into the power
outlet, and place the power cord in a safe position. Do not touch, install or unplug the
power cord with wet hands to avoid electric shock accidents.
Before unplugging the power cord, please turn off the machine power in the correct
procedure, otherwise it may cause damage to the machine.
If don't use the machine for a long time, please unplug the power supply.
Before operation, please check whether the air inlet and outlet positions of the machine
are blocked.
Do not put debris at the air inlet or outlet, because there is the fan installed inside with
high-speed rotation, it may caused injured if touch it.
In order to ensure the best performance of the machine, do not place any obstacles within
1 meter nearby of the air outlet position and air introduction position.
The machine has precision components built inside. Don't open the case by yourself to
avoid damage to the machine parts and may happen dangerous.
Do not dismantle the front wind panel or the chassis during machine is operating to avoid
dangerous.
Pay attention to ventilation when using it together with fuel appliances. Please do not use
machine in the kitchen.
Before cleaning the chassis of the machine, make sure turn off the power and unplug it of
the machine.Only use cloth with a little clean water and clean it softly,don't use volatile
cleaners.
Forbidding to place and using in the bathroom, otherwise it may cause electric shock.
There are electronic devices installed inside, do not open the case to avoid the risk of electric shock.
Please read this [user manual] carefully before using the machine and follow the below points of
operation base on the manual.Otherwise It may cause damage to product, or even cause injury
to yourself or others at varying degrees.
1.Please read this manual carefully before use.
2.Free services can be provided with warranty card and invoice,welcome to contact us
if you need technical support.
3.Customers can get 1 year warranty service from us with product related invoice and
documents.
4.Please keep the warranty card properly so that the warranty can be obtained when
the product needs repair.
5.The company is not responsible for the following repair services beyond the product,
but we can still provide you with paid services.
Products due to improper use or storage.
Products without warranty card or other valid documents.
Products due to unstable power supply voltage or beyond the normal voltage
range or power supply and installation does not meet the electrical installation
requirements.
Promotional products.
Products damaged caused by irresistible natural disasters.
Products beyond maintenance period,damaged due to not follow the rules and
methods of application.
Maintenance notice Composition unit
Control panel
DC24V
Air outlet
Air outlet
Air inlet
Safe Lock
Machine
lock
①② ③ ④
①Fuse ②Work lights
③Power switch ④Power socket
Model
Voltage
Area
Power
Air volume
Weight
Noise Ion tube
Size Ion tube size
PS-500T2
DC24V
50-100㎡
≤50db
260*175*60mm
23W
0-220m³/h
3Kg
2(Standard)
80mm(3inch)
Filter type Ion tube lifePrimary effect filter ≤2 years
Technical specification
Plasma ions generator play a long-lasting and active positive and negative ion purification effect.
Shell is metal material
This product can be used for a long-term.(Suggest clean the ion tube about 12 months later,
clean or change the filter)

Popular Laboratory Equipment manuals by other brands

GYROZEN 1096R Service manual

GYROZEN

GYROZEN 1096R Service manual

CASHIDO 10 Second Machine Commercial OH6800 Series user manual

CASHIDO

CASHIDO 10 Second Machine Commercial OH6800 Series user manual

Celestron 44420 Information, Specifications and Instructions

Celestron

Celestron 44420 Information, Specifications and Instructions

biochrom Anthos 2010 quick start guide

biochrom

biochrom Anthos 2010 quick start guide

Molecular Devices SkanWasher 300 user guide

Molecular Devices

Molecular Devices SkanWasher 300 user guide

OHAUS ACHIEVER e-A51ST020 user guide

OHAUS

OHAUS ACHIEVER e-A51ST020 user guide

Varian 4000 MS user guide

Varian

Varian 4000 MS user guide

biochrom EZ Read 400 quick start guide

biochrom

biochrom EZ Read 400 quick start guide

Buchi K-370 quick guide

Buchi

Buchi K-370 quick guide

International Biomedical AeroNOx operating manual

International Biomedical

International Biomedical AeroNOx operating manual

Biobase BCI-I user manual

Biobase

Biobase BCI-I user manual

PI L-505.02A212F user manual

PI

PI L-505.02A212F user manual

Foss Soxtec 1047 user manual

Foss

Foss Soxtec 1047 user manual

BIO RAD Experion User quick guide

BIO RAD

BIO RAD Experion User quick guide

Emerson Rosemount 700XA Reference manual

Emerson

Emerson Rosemount 700XA Reference manual

Brookfield TC-150MX Operator's manual

Brookfield

Brookfield TC-150MX Operator's manual

IEC MASH BATH manual

IEC

IEC MASH BATH manual

Scilogex MX-RD-PRO user manual

Scilogex

Scilogex MX-RD-PRO user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.