manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Plum
  6. •
  7. Measuring Instrument
  8. •
  9. Plum MacR6 N User manual

Plum MacR6 N User manual

installaon manual
MacR6 N
1
• 2 - Necessary accessories
• 4 - Watermeter assembly
• 3 - SIM card assembly and slot sealing
• Torx T10 screwdriver
• 1 - Contents of package
• Watermeter adapter kit
• MacR6 N
• 6 Torx T10 M12 screws
• 2 plasc tack rivets
• H-type silicone gel in syringe
• Smartphone or tablet with NFC support
• Data Loggers Congurator NFC applicaon
– QR code redirects to Google Play store
1. Open the front cover (g. 3.1).
2. Open the SIM card cap, take out the SIM holder (g. 3.2).
3. Install the SIM card according to g. 3.3. Insert the SIM holder into the
slot.
4. Using the syringe, seal the surface of the SIM holder (see gure 3.4 and
3.5), being sure to ll the small plasc moat surrounding the SIM card
and holder.
5. Put the SIM card cap back on, covering the SIM card.
6. Put the front cover onto the device then close it with the included Torx
screws.
1. Select the adapter dedicated for the watermeter.
2. Install the adapter using the included screws.
3. Install the MacR6 N on the adapter using tack rivets (g. 4.3.).
ITRON adapter is can be aached to a pipe using cable es (g. 4.1) or
to the wall using pegs (g. 4.2).
• MicroSIM card
• ITRON
• MADDALENA
• SENSUS
Fig. 4.1. Fig. 4.2.
Fig. 3.1.
Fig. 3.3. Fig. 3.4.
Fig. 3.2.
SIM
• ZENNER
Fig. 3.5. Fig. 3.6. Fig. 4.3.
x2
INSTALLATION
• DIEHL
2
• 7 - eWebtel.com
PLUM Sp. z o.o.
Wspólna 19, Ignatki, 16-001 Kleosin, Poland
Technical Department
tel.: 85 749 70 08, fax.: 85 749 70 14, e-mail: [email protected]
installaon manual
MacR6 N
• 5 - Connecon with MacR6 N
• 6 - Conguraon of parameters
1. Turn on the NFC on smartphone or tablet.
2. Start ConfIT - data loggers applicaon, choose NFC communicaon and
close phone to the MacR6 N.
1. Take the smartphone or tablet o of the MacR6 N aer the readout has
been generated.
2. Enter data into the watermeter- pulse factor, counter value, serial
number. Enter the PIN to the SIM card. By clicking ”More parameters”
you are able to set advanced values such as registraon period, data
server address, or installaon phone number.
1. Connect with MacR6 N.
2. Go to MOBILE CONNECTION tab using menu on the le side. Pick
COMMAND and choose INSTALLATION - SEND FULL REPORT.
3. Close the smartphone to MacR6 N to save conguraon.
DEVICE IS CONFIGURED AND READY TO USE
There is no specic posion for phone placement. It depends on locaon
of NFC antenna inside the smartphone.
3. Save the conguraon. Tick the Save to device buon and close
smartphone to MacR6 N.
4. Successful saving will be indicated by the message below.
When programmed - device will go to water meter recognion mode
what is indicated with proper message in main window.
Water meter detecon is possible in few seconds when water ow is
present. When recognized app will show proper informaon.
When detecon takes too much me please proceed with installaon
once again.
ISSUE: MacR6 N_installaon manual_EN_3.0.pdf
327.55 0.00

Other manuals for MacR6 N

4

Popular Measuring Instrument manuals by other brands

Trace2O METALYSER HM1000 instruction manual

Trace2O

Trace2O METALYSER HM1000 instruction manual

Mastech MS8238G user manual

Mastech

Mastech MS8238G user manual

IMV Easi-Scan: Go instruction manual

IMV

IMV Easi-Scan: Go instruction manual

Temtop PMD 351 user manual

Temtop

Temtop PMD 351 user manual

Datacold 600 R quick start guide

Datacold

Datacold 600 R quick start guide

Dräger MP04551 Instructions for use

Dräger

Dräger MP04551 Instructions for use

Hanna Instruments Checker HI 716 quick start guide

Hanna Instruments

Hanna Instruments Checker HI 716 quick start guide

ECD V-M.O.L.E. Quick reference guide

ECD

ECD V-M.O.L.E. Quick reference guide

FMC Technologies INVALCO 64908265 Installation & operation manual

FMC Technologies

FMC Technologies INVALCO 64908265 Installation & operation manual

Endress+Hauser Liquiphant FTL51B Safety instruction

Endress+Hauser

Endress+Hauser Liquiphant FTL51B Safety instruction

Blue Sea Systems M2 OLED instructions

Blue Sea Systems

Blue Sea Systems M2 OLED instructions

SSE Sharky 773 user guide

SSE

SSE Sharky 773 user guide

Circuit-test DMS-4420 manual

Circuit-test

Circuit-test DMS-4420 manual

Louroe Electronics ASK-4 122 Installation and operating instructions

Louroe Electronics

Louroe Electronics ASK-4 122 Installation and operating instructions

Halma Alicat Scientific L quick start guide

Halma

Halma Alicat Scientific L quick start guide

Rice Lake 1280 Enterprise Series installation manual

Rice Lake

Rice Lake 1280 Enterprise Series installation manual

Extech Instruments 461891 user guide

Extech Instruments

Extech Instruments 461891 user guide

Bender iso685 manual

Bender

Bender iso685 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.