Power Controller Guide
Introduction
This power controller box provides power for the Plustek NVR (Network Video
Recorder), DC12V surveillance cameras, and DC12V Video Server on the motor
vehicles. In normal operational conditions, this device receives battery DC power and
transforms to stable DC power for the NVR and related electronics equipments. This
intelligent power module contains self-protection function to effectively protect your
vehicle power. When the car battery voltage reaches the cut off limit, this device will
stop providing power for the NVR and related equipments in order to protect the car
battery. Hence, the battery voltage is avoided to be too low to start the engine for
insuring normal operation.
Safety Precautions
1. Please be well aware of the hazards during the installation. The power controller
box contains hazardous voltages. It should be tested and installed by qualified
technicians who are trained in the use of power systems.
2. Do not touch the input and output terminals when power is applied. These areas
are at hazardous voltage potentials.
3. The power controller cover should not be removed because the internal voltages
are at hazardous potentials. Removing the box cover will void the warranty.
Box Contents
1. Power Controller Box
2. Screws
3. Quick Guide
Overview
1
1. Battery Cable
2. Camera Cable
3. Video Server Cable
4. NVR Cable
To set up the Power Controller box in vehicle environment
1. Wire the Battery cable to the vehicle’s battery.
2. Wire the Camera cable to the surveillance camera (no adapter needed).
3. Connect the Video Server cable to the DC-Jack power input of the Video Server.
4. Connect the NVR cable to the DC-Jack power input of the NVR.
5. Fix the power controller box with screws to the desired location.
Specifications
Model Name NP 120
Input Voltage 12VDC
Input Voltage Range 9~36 VDC
Max Input Current at No Load 185mA
Output Voltage 12VDC
Cut Off Voltage 10.5V
Power Consumption 5W
Output Adjustment 9.6-13.2V with internal trimpot
Max Output Current(s) 6.3A
Max Output Power (milliseconds) 75 Watts
Max Output Power (3 seconds) 75 Watts
Max Output Power (continuous) 43 Watts
Output Plug Type Screw Terminal Standard
Efficiency 88%
Line Regulation 24 mV
Load Regulation 30 mV
Switching Frequency 300 KHz
Output Ripple Noise 100mVp-p
Remote power on/off Yes
Connections Screw terminals
Protection Over Voltage, Over Current, Short Circuit,
Reverse Polarity, Over Temperature
Dimensions 160x140x42.2mm (6.30x5.51x1.66 inches)
Weight 985g (2.17 lbs)
2
Model Name NP 120-100W
Input Voltage 12VDC
Input Voltage Range 9~18 VDC
Max Input Current at No Load 185mA
Output Voltage 12VDC
Cut Off Voltage 10.5V
Power Consumption 5W
Output Adjustment 9.6-13.2V with internal trimpot
Max Output Current(s) 8.4A
Max Output Power (milliseconds) 100 Watts
Max Output Power (3 seconds) 100 Watts
Max Output Power (continuous) 60 Watts
Output Plug Type Screw Terminal Standard
Efficiency 88%
Line Regulation 24 mV
Load Regulation 30 mV
Switching Frequency 300 KHz
Output Ripple Noise 100mVp-p
Remote power on/off Yes
Connections Screw terminals
Protection Over Voltage, Over Current, Short Circuit,
Reverse Polarity, Over Temperature
Dimensions 160x140x42.2mm (6.30x5.51x1.66 inches)
Weight 985g (2.17 lbs)
Model Name NP 240
Input Voltage 24VDC
Input Voltage Range 9~36 VDC
Max Input Current at No Load 185mA
Output Voltage 12VDC
Cut Off Voltage 20.5V
Power Consumption 5W
Output Adjustment 9.6-13.2V with internal trimpot
Max Output Current(s) 6.3A
Max Output Power (milliseconds) 75 Watts
Max Output Power (3 seconds) 75 Watts
Max Output Power (continuous) 43 Watts
3
Output Plug Type Screw Terminal Standard
Efficiency 88%
Line Regulation 24 mV
Load Regulation 30 mV
Switching Frequency 300 KHz
Output Ripple Noise 100mVp-p
Remote power on/off Yes
Connections Screw terminals
Protection Over Voltage, Over Current, Short Circuit,
Reverse Polarity, Over Temperature
Dimensions 160x140x42.2mm (6.30x5.51x1.66 inches)
Weight 985g (2.17 lbs)
Model Name NP 240-100W
Input Voltage 24VDC
Input Voltage Range 9~36 VDC
Max Input Current at No Load 185mA
Output Voltage 12VDC
Cut Off Voltage 20.5V
Power Consumption 5W
Output Adjustment 9.6-13.2V with internal trimpot
Max Output Current(s) 8.4A
Max Output Power (milliseconds) 100 Watts
Max Output Power (3 seconds) 100 Watts
Max Output Power (continuous) 60 Watts
Output Plug Type Screw Terminal Standard
Efficiency 88%
Line Regulation 24 mV
Load Regulation 30 mV
Switching Frequency 300 KHz
Output Ripple Noise 100mVp-p
Remote power on/off Yes
Connections Screw terminals
Protection Over Voltage, Over Current, Short Circuit,
Reverse Polarity, Over Temperature
Dimensions 160x140x42.2mm (6.30x5.51x1.66 inches)
Weight 985g (2.17 lbs)
4
Model Name NP 480-75W
Input Voltage 48VDC
Input Voltage Range 18~75 VDC
Max Input Current at No Load 185mA
Output Voltage 12VDC
Cut Off Voltage 33V
Power Consumption 5W
Output Adjustment 9.6-13.2V with internal trimpot
Max Output Current(s) 6.3A
Max Output Power (milliseconds) 75 Watts
Max Output Power (3 seconds) 75 Watts
Max Output Power (continuous) 43 Watts
Output Plug Type Screw Terminal Standard
Efficiency 88%
Line Regulation 24 mV
Load Regulation 30 mV
Switching Frequency 300 KHz
Output Ripple Noise 100mVp-p
Remote power on/off Yes
Connections Screw terminals
Protection Over Voltage, Over Current, Short Circuit,
Reverse Polarity, Over Temperature
Dimensions 160x140x42.2mm (6.30x5.51x1.66 inches)
Weight 985g (2.17 lbs)
5

This manual suits for next models

5

Popular Controllers manuals by other brands

Elko HRH-4 manual

Elko

Elko HRH-4 manual

HORNER XL6 Series installation manual

HORNER

HORNER XL6 Series installation manual

Protege PRT-CTRL quick start guide

Protege

Protege PRT-CTRL quick start guide

Danfoss ACI 30-1 instructions

Danfoss

Danfoss ACI 30-1 instructions

EMKO EAOM-210 FLJ user manual

EMKO

EMKO EAOM-210 FLJ user manual

THORLABS TDC001 user guide

THORLABS

THORLABS TDC001 user guide

ICM Controls ICM271 Installation, operation & application guide

ICM Controls

ICM Controls ICM271 Installation, operation & application guide

Mandik MONZUN VULCAN Installation and operation instruction

Mandik

Mandik MONZUN VULCAN Installation and operation instruction

American Lighting LED-RGB-CTRL-24V installation instructions

American Lighting

American Lighting LED-RGB-CTRL-24V installation instructions

Hugo Lahme AllFit 1702050 user manual

Hugo Lahme

Hugo Lahme AllFit 1702050 user manual

YGE ProgCard III user guide

YGE

YGE ProgCard III user guide

Zamel SRP-03 Manual instruction

Zamel

Zamel SRP-03 Manual instruction

Lindab UltraLink FTCU Mounting instructions

Lindab

Lindab UltraLink FTCU Mounting instructions

Dawicontrol DC-154 RAID manual

Dawicontrol

Dawicontrol DC-154 RAID manual

Johnson Controls Metasys VMA1610 installation instructions

Johnson Controls

Johnson Controls Metasys VMA1610 installation instructions

RS 1/8-DIN product manual

RS

RS 1/8-DIN product manual

Switchmate Home SimplySmartHome Secure Quick start guides

Switchmate Home

Switchmate Home SimplySmartHome Secure Quick start guides

Prince Antec Controls Retrofit manual

Prince

Prince Antec Controls Retrofit manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.