
1. Switch off the main circuit breaker.
2. Connect the receiver acc. to the diagram.
3. Switch on the main circuit breaker; the green diode
flashes on the receiver; thus the receiver is ready for
further setting.
4. Shortly press the FUNCTION BUTTON for about
1.5 s (the green and red diode are flashing alternately).
5. On the PH-BSP control unit, press the “Test” button in
the ACTIV mode to activate the SP
switching components (see page 10
of the PH-BSP instructions).
6. If the code has been learned correctly,
the green and red diodes flash
simultaneously.
LED 2
LED 1
empty memory, code not learned
code learned
FLASHING ALTERNATELY= code learning mode
FLASHING SIMULTANEOUSLY= code has been learned
SIMULTANEOUS LONG FLASH= code was ERASED
relay switched
ERROR (if no signal is received from the transmitter
within approx. 6 hours, it switches to the 2-min-ON /
8-min-OFF mode). LED flashes only if the relay is on,
i.e. for 2 minutes.
EXPLANATION: LIT UNLIT FLASHING
FUNCTION
ACTIVATION PROCEDURE
INDICATION DIODES
ph_sp1_en:Layout 1 18.3.2011 13:19 Page 3