CONTROL BUTTONS ON THE DEHUMIDIFIER
Other features
Bucket Full Light
Glows when the bucket is ready to be
emptied.
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.
Auto Defrost
Wait 3 minutes before resuming operation
After the unit has stopped, it cannot restart
opertation in the first 3 minutes. This is to protect
the unit. Operation will automatically start after
3 minutes.
Setting the Timer
Check filter feature
The system starts to count the time once the fan
motor operates. The check filter feature can be
only activated when the accumulated operation
time achieves 250 hours or more. The Reset
light (Clean filter indicator light) flashes at one time
per second, after finishing clean the air filter, press
the Filter button and the Reset light (Clean filter indicator
light) goes off.
Auto Shut Off
The shuts off when the bucket is
full, or when the bucket is removed or not replaced
in the proper position. When the setting humidity is
reached, the unit will be shut off automatically.
For some models, the fan motor will continue
operating.
dehumidifier
Auto-Restart
If the unit breaks off unexpectedly due to the power cut,
it will restart automatically with the previous function setting
when the power resumes.
9
Display
Shows the set % humidity level from 35% to 85% or auto
start/stop time (0~24) while setting, then shows the actual
(±5% accuracy) room % humidity level in a range of
RH (Relative Humidity) to 90%RH (Relative Humidity).
Error Codes and Protection Code:
AS- Humidity sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
ES- Tube Temperature sensor of the evaporator error-- Unplug
the unit and plug it back in. If error repeats, call for service.
P2- Bucket is full or bucket is not in right position-- Empty
the bucket and replace it in the right position .(Only available for
the uint with no pump feature.)
P2- Bucket is full -- Empty the bucket. (Only available for the
unit with pump feature.)
30%
EC- Refrigerant leakage detection-- With this new technology,
the display area will appear EC when the unit detects
refrigerant leakage, call for service.
E3- Unit malfunction-- Unplug the unit and plug it back in. If
error repeats, call for service.
Eb- Bucket is removed or not in right position-- Replace the
bucket in the right position. (Only available for the unit with
pump feature.)
When the unit is on, first press the Timer button, the
Timer Off indicator light illuminates. It indicates the Auto
Stop program is initiated. Press it again the Time On
indicator light illuminates.It indicates the Auto Start is
initiated.
When the unit is off, first press the Timer button, the
TIMER ON indicator light illuminates. It indicates the
Auto Start program is initiated. Press it again the Time
Off indicator light illuminates.It indicates the Auto Stop
is initiated.
Press or hold the UP or DOWN button to change the Auto
time by 0.5 hour incre- ments, up to 10 hours, then at 1
hour increments up to 24 hours. The control will count
down the time remaining until start.
The selected time will register in 5 seconds and the system
will automatically revert back to display the previous humidity
setting.
When the Auto start & Auto stop times are set, within the
same program sequence, TIMER ON OFF indicator lights
illuminate to indicate both ON and OFF times are now
programmed.
Turning the unit ON or OFF at any time or adjusting the
timer setting to 0.0 will cancel the Auto Start/Stop function.
When LED display window displays the code of P2, the
Auto Start/Stop function will also be cancelled.