*2) Time (in seconds) overcome SET for entry in alarm condition.
*3) Time (in seconds) sampling wind speed; for low value can read a quick change of
*1) HP33 can be configurated in these different wind meter representation:
0 : Km/h wind speed range (max 100).
1: m/sec wind speed range (max 30).
2 : Knots wind speed range (max 60).
3 : RPM wind speed range (max 5000).
These settings refer to the operation mode of the system and must be made on
initial startup. Press - / + at the same time for at least one second: the message
C.O.S.t. will be displayed.
Press than repeatedly TIME until the message regarding the chosen variable is
displayed (see table below) : value of variable and message will be displayed.
Press + or - to set a new value and then press TIME to confirm.
The next system constant will then appear.
You can press TIME for at least 2 seconds to exit and return to the Run Mode.
COSt PROGRAMMING (System constants)
wind speed on display,
AL.OFF
AL.ON
SPEED 1 SENSOR
C on d it i on at e d
by Minimu time
gust o f wi n d
(t.rit)
Conditionated by
Minimum time of
al ar m durati on
t.dur .AL.OFF
AL.ON
SPEED 2 SENSOR
C on d it i on at e d
by Minimu time
gust o f wi n d
(t.rit)
Conditionated by
Minimum time of
al ar m durati on
t.dur .
OPERATING DIAGRAMS
Mess. Value Meaning Note
tYPE 0 Wind speed representation *1
t.rit 2" Minimum time (in seconds) gust of wind *2
rEAd 1" Integration time (in seconds) wind reading *3
n.CAL =2 Number of impulses of WX sensor
VIEWING WIND SPEED RECORDING
Press WIND 1 together with + : will be displayed followed
by Maximum Wind Speed 1.
Values are permanently stored in the memory: for deleting all values in the memory keep
pushed + key for more than 3 seconds: CLEA message will appear on display before
clearing operation.
Press WIND 2 together with + : will be displayed followed
by Maximum Wind Speed 2.
The light situated at the bottom of the display shows the state of the controller:
STATE INDICATION LAMPS
Speed value displayed are just indication.
Lamp. State N° Relay Contacts
DANGER 1 Zone 1 Alarm On 1 3-4-5
DANGER 2 Zone 2 Alarm On 1 6-7-8
Km/h Km/h representation
m/sec m/sec representation
Knots Knots representation
WIND SPEED REPRESENTATION
ALARM 1 ON ALARM 2 ON
This processor is already programmed with the following (variable) settings.
To return to these settings at any time you may:
Power off the processor, press TIME key and keep it pressed giving power on:
boot message will be displayed (release now TIME key).
SEt.1=30.0u SEt.2=30.0u t.dur=60" .
The COSt values are shown in paragraphs 1.2
PRESET PROGRAMS
MANUAL MODE
In some start-up conditions may be useful to work in "manual" mode:
Power off the processor, press + key and keep it pressed giving power on:
HAnd message will be displayed (release now + key).
Push + until is displayed number required to be handed (see table State
indication lamps ) and push TIME for activing relay.
Pushing again + for increase relay number previous relay is disactivated.
You can press TIME key for a least two seconds to escape and return to the Run Mode.