manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Power Inspired
  6. •
  7. UPS
  8. •
  9. Power Inspired VIX3065 User manual

Power Inspired VIX3065 User manual

This manual suits for next models

4

Other Power Inspired UPS manuals

Power Inspired Willo User manual

Power Inspired

Power Inspired Willo User manual

Power Inspired VFI6KT User manual

Power Inspired

Power Inspired VFI6KT User manual

Power Inspired VFI-C Series 1KR User manual

Power Inspired

Power Inspired VFI-C Series 1KR User manual

Power Inspired iPower-DC2 User manual

Power Inspired

Power Inspired iPower-DC2 User manual

Power Inspired VIX2060 User manual

Power Inspired

Power Inspired VIX2060 User manual

Power Inspired VIS0750 User manual

Power Inspired

Power Inspired VIS0750 User manual

Power Inspired VFI1000QS User manual

Power Inspired

Power Inspired VFI1000QS User manual

Popular UPS manuals by other brands

AEG Protect 3.M 2.0 manual

AEG

AEG Protect 3.M 2.0 manual

Alpha Novus FXM 650 Installation and operation manual

Alpha

Alpha Novus FXM 650 Installation and operation manual

CyberPower RB12120X2A user manual

CyberPower

CyberPower RB12120X2A user manual

Pylontech Victron & Pylontech US5000 manual

Pylontech

Pylontech Victron & Pylontech US5000 manual

BEL LDX-U20 user manual

BEL

BEL LDX-U20 user manual

Mustek PowerMust 530(B) Plus Startup manual

Mustek

Mustek PowerMust 530(B) Plus Startup manual

Emerson Liebert NXL series Operation and maintenance manual

Emerson

Emerson Liebert NXL series Operation and maintenance manual

MAKELSAN BOXER SERIES user manual

MAKELSAN

MAKELSAN BOXER SERIES user manual

Block PC-0524-400-0 manual

Block

Block PC-0524-400-0 manual

CyberPower CP585LCD user manual

CyberPower

CyberPower CP585LCD user manual

Eaton 3S Advanced user's guide

Eaton

Eaton 3S Advanced user's guide

CyberPower Office Tower Series UPS 1000 user manual

CyberPower

CyberPower Office Tower Series UPS 1000 user manual

CyberPower BM100 quick start guide

CyberPower

CyberPower BM100 quick start guide

Best Power 610 quick start guide

Best Power

Best Power 610 quick start guide

Best Power Unity/I UT3K user manual

Best Power

Best Power Unity/I UT3K user manual

Mustek PowerMust 400 Offline user manual

Mustek

Mustek PowerMust 400 Offline user manual

Xantrex Trace 512 UR-UPS owner's manual

Xantrex

Xantrex Trace 512 UR-UPS owner's manual

Forza SL-1501UL user manual

Forza

Forza SL-1501UL user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

POWER
Inspired
VIX3000 Series Line Interactive
UPS System
Important Safety Warning (SAVE THESE INSTRUCTIONS)
CAUTION!
acceptable temperature and humidity range.)
CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and
avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances
such as space heaters or furnaces.
CAUTION! Do not attach non-computer-related items, such as medical equipment,
life-support equipment, microwave ovens, or vacuum cleaners to UPS.
CAUTION! Do not plug the UPS input into its own output.
CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages
or any other liquid-containing vessels on or near the unit.
CAUTION! In the event of an emergency, press the OFF button and disconnect the power
cord from the AC power supply to properly disable the UPS.
CAUTION! Do not attach a power strip or surge suppressor to the UPS.
CAUTION! If the UPS is with metal chassis, for safety purpose, grounding is a must during
UPS installation in order to reduce leakage current below 3.5mA.
Attention hazardous through electric shock. Also with disconnection of this unit from the
mains, hazardous voltage still may be accessible through supply from battery. The battery
supply should be therefore disconnected in the plus and minus pole at the quick connectors of
the battery when maintenance or service work inside the UPS is necessary.
CAUTION! Servicing of batteries should be performed or supervised by personnel
knowledgeable of batteries and the required precautions. Keep unauthorized personnel away
from batteries.
CAUTION! When replacing the batteries, use the same number and type of batteries.
CAUTION! Internal battery voltage is 12VDC. Sealed, lead-acid, 6-cell battery.
CAUTION!
mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes.
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
CAUTION! A battery can present a risk of electric shock and high short circuit current. The
following precaution should be observed before replacing batteries:
1) Remove watches, rings, or other metal objects.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or disconnecting batteries terminal.
If your UPS came with a software CD, follow the instructions on the CD, otherwise:
1. Go to the website http://www.power-software-download.com
2. Click ViewPower software icon and then choose your required OS to download the software.
3. Follow the on-screen instructions to install the software.
Software Download & Installation
Power Inspired Ltd. Units 5-7 High Point, Riding Road, Brackley UK.
Tel: 01280 811180
www.powerinspired.com VIX3000-REV1
Model VIX3065 VIX3085 VIX3100 VIX3150 VIX3200
CAPACITY
INPUT
Voltage
Voltage Range
OUTPUT
Voltage Regulation
Transfer Time
Waveform
BATTERY
Type & Number
Charging Time
PHYSICAL
Dimension (DxWxH mm)
Net Weight (kgs)
ENVIRONMENT
Humidity
Nosie Level
MANAGEMENT
USB
650VA/360W 850VA/480W 1000VA/600W 1500VA/900W 2000VA/1200W
287 x 100 x 142 350x146x160 397 x 146 x 205
12V/7AHx1 12V/9AHx1 12V/7AHx2 12V/9AHx2 12V/9AHx2
4-6 hours recover to 90% capacity
4.25 4.9 8.0 11.1 11.5
220/230/240 VAC
162-290 VAC
+/-10%
Typical 2-6 ms, 10 ms max.
Simulated Sine Wave
0-90 % RH @ 0-40 C (non-condensing)
Less than 40 dB
Supports Windows® 2000/2003/XP/Vista/2008, Windows®7/8
Linux, Unix and MAC
6
4
5
7
8 3 9
Product Overview
Introduction
Thank you for purchasing a Power Inspired Uninterruptible Power Supply. For further
information on this product or for support please visit www.powerinspired.com/vix3000/
Installation & Operation
NOTE: Before installation, please inspect the unit. Be sure that nothing inside
the package is damaged.
Placement & Storage Conditions
Please place the UPS away from other units at least 20 cm to avoid interference. Do NOT
operat
check the specs for the limitations.)
6 hours
Connect to Utility and Charging
Plug in the AC input cord to the wall outlet. For the best results,
suggest to charge the battery at least 6 hours before initial use.
The unit charges its battery while connecting to the utility.
Connect the Loads
Plug in the loads to output receptacles on the rear panel of the UPS. Simply turn on the
power switch of UPS unit, then devices connected to the UPS will be protected by UPS unit.
Connect Modem/Phone/Network for Surge Protection
Connect a single modem/phone line into surge-protected “IN” outlet on the back panel of
the UPS unit. Connect from “OUT” outlet to the computer with another phone line cable.
Connect Communication Cable
To allow for unattended UPS shutdown/start-up and status monitoring, connect the
communication cable one end to the USB/RS-232 port and the other to the communication
port of your PC. With the monitoring software installed, you can schedule UPS
shutdown/start-up and monitor UPS status through PC.
Turn On/Off the Unit
Turn on the UPS unit by pressing the power switch.
Turn off the UPS by pressing the power switch again.
Problem Possible Cause Solutions
AC input is not connected
well.
Check if the input power
connected to the mains.
AC input is connected to the
UPS output.
Plug AC input power cord to AC input
correctly.
Battery backup time is
shorter than nominal
value.
Batteries are not fully
charged.
Charge the batteries at least 6 hours
and then check the capacity again.
If the problem still persists, please
consult your dealer.
Batteries defect. Contact your dealer to replace the
batteries.
Warning or fault icon
is shown and alarm is
continuously
sounding.
Fan is locked or not working. Check fans and notify your dealer.
The UPS is overload.
reconnecting devices, please verify
the total loads match the UPS
spec.
Low battery icon is
shown on the LCD
screen.
Low battery. Charge the UPS at least 6 hours.
Troubleshooting
LCD blank / No LEDs
illuminated when
mains is normal
Power switch
LCD panel
Output receptacles
AC input
Circuit breaker / Fuse
Modem/Phone/Network surge
protection
USB com port
1
2
3
4
5
Power switch
UPS status LED
AC mode: green lighting
LED Models LCD Models
CAUTION: NEVER connect a laser printer or scanner to
the UPS unit. This may cause the damage of the unit.
Fault : Red lighting
1. Input information 6. Battery capacity indicator
2. Output information 7. Overload indicator
3. AC mode indicator 8. Low battery indicator
4. Battery mode indicator 9. Fault indicator
5. Load level indicator
650V/850VA
2
4
5
11
2
3
4
5
1
4
2
5
1KVA 1.5KVA/2KVA