manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Power Tec
  6. •
  7. Switch
  8. •
  9. Power Tec PSI NXG-Vision PS18L-U2 User manual

Power Tec PSI NXG-Vision PS18L-U2 User manual

This manual suits for next models

1

Other Power Tec Switch manuals

Power Tec 71054 User manual

Power Tec

Power Tec 71054 User manual

Power Tec 71355 User manual

Power Tec

Power Tec 71355 User manual

Power Tec 71006 User manual

Power Tec

Power Tec 71006 User manual

Power Tec 71443 User manual

Power Tec

Power Tec 71443 User manual

Power Tec 71442 User manual

Power Tec

Power Tec 71442 User manual

Popular Switch manuals by other brands

SMC Networks SMC6224M Technical specifications

SMC Networks

SMC Networks SMC6224M Technical specifications

Aeotec ZWA003-S operating manual

Aeotec

Aeotec ZWA003-S operating manual

TRENDnet TK-209i Quick installation guide

TRENDnet

TRENDnet TK-209i Quick installation guide

Planet FGSW-2022VHP user manual

Planet

Planet FGSW-2022VHP user manual

Avocent AutoView 2000  AV2000BC AV2000BC Installer/user guide

Avocent

Avocent AutoView 2000 AV2000BC AV2000BC Installer/user guide

Moxa Technologies PT-7728 Series user manual

Moxa Technologies

Moxa Technologies PT-7728 Series user manual

Intos Electronic inLine 35392I operating instructions

Intos Electronic

Intos Electronic inLine 35392I operating instructions

Cisco Catalyst 3560-X-24T Technical specifications

Cisco

Cisco Catalyst 3560-X-24T Technical specifications

Asante IntraCore IC3648 Specifications

Asante

Asante IntraCore IC3648 Specifications

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Siemens

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Edge-Core DCS520 quick start guide

Edge-Core

Edge-Core DCS520 quick start guide

RGBLE S00203 user manual

RGBLE

RGBLE S00203 user manual

Thrustmaster FLIGHT SIMULATOR X quick guide

Thrustmaster

Thrustmaster FLIGHT SIMULATOR X quick guide

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Southwire

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Buhler Nivotemp NT 61 Brief instructions

Buhler

Buhler Nivotemp NT 61 Brief instructions

Kramer VS-41HDCP user manual

Kramer

Kramer VS-41HDCP user manual

Techly IDATA AU-270 user manual

Techly

Techly IDATA AU-270 user manual

Belkin F1U109 user manual

Belkin

Belkin F1U109 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

DC Output/Telemetry Connector
AC Input Power Cord Connector
CONNECTION POINTS FOR VAC (INPUT) AND
VDC/TELEMETRY (OUTPUT)
(BOTTOM VIEW OF MODEL PS18L-U7)
MODEL PS18L-U2 OFFERS A 2 CONDUCTOR HARD WIRE VDC OUTPUT
CABLE ONLY IN PLACE OF THE 7 CONDUCTOR VDC/TELEMETRY OUTPUT
OFFERED WITH MODEL PS18L-U7.
MODEL AUDIBLE ALARM VISUAL ALARM RELAY ALARM TO ONT
PS18L-U7 YES YES YES
PS18L-U2 YES YES NO
*RELAY ALARM FROM PS18L-U7 TO ONT (OPTICAL NETWORK
TERMINAL) RELAYS BATTERY ALARMS: 1. LOW BATTERY; 2. ON
BATTERY; 3. BATTERY MISSING; 4. REPLACE BATTERY
NOTE:
USER'S MANUAL FOR
NXG-Vision
(Next Generation FTTx Micro UPS)
For Model Numbers:
PS18L-U2 & PS18L-U7
WARNINGS
Review the following important safety warnings to avoid bodily injury or damage
to equipment during installation or operation of this device.
Read ALL instructions before attempting to install or operate this device.
This device is intended for indoor use only. To prevent the risk of fire or
eletrical shock, install in dry location free from damp or wet environment,
or potentially damp or wet environment.
Adhere to all acceptable operating environment limitations as listed to
prevent the risk of of fire or electrical shock (see user specifications within
User's Manual)
Risk of fire or explosion if improper battery pack is installed and
attempted to operate with this device. Device is rated and approved for
use with PowerTec Solutions Internation Li Ion Battery Pack ONLY.
Follow User Manual instructions for proper installation and removal of
battery pack.
NO user-replaceable parts within this device. Do not remove cover for
any reason.
NOTE: The reference to "NXG-Vision" within this User Manual refers to
PowerTec Solutions Models PS18L-U2 and PS18L-U7 (Next Generation FTTx
Micro UPS) and all package accessories as listed below.
CONTENTS OF NXG-Vision PACKAGE
NOTE: Please verify all standard contents are accounted for upon receipt of
NXG-Vision.
STANDARD: (1) Power Supply/Charger; (1) Li Ion Battery Pack; (1) AC Power
Cord; (1) 7-Pin Connector; (1) User's Manual
Optional: (1) Universal Wall Mount Enclosure w/ Cover (associated with Model
PS18UN), or (1) Wall Mount Cradle w/ Cover (associated with Model PS18CR).
NXG-Vision INTRODUCTION
NXG-Vision is designed and intended for use as Desktop or Wall-mount (when
ordered with optional Universal or Cradle wall mount enclosures) DC power
supply and battery back up device for 12Vdc Optical Network Terminals (ONT).
The NXG-Vision not only provides constant supply of DC power during normal
operating conditions, but offers battery backup power in case of electrical power
outage. NXG-Vision also provides customer facing Network Interface Reset
Intelligence to provide integrated ONT reset technology designed to reduce
Provider OPEX.
VISUAL INDICATORS AND CONTROL SWITCHES
1
3
5
6
4
2
1 System Status Color-Green
2 DC Color-Green
3 Mute Color-Yellow
4Battery Color-Red
NXG-Vision is receivingAC power load to
operate under normal conditions.
NXG-Vision is working off Standby Power.
Flashing-Audible Alarm silenced for 24hrs
Solid-Audible Alarm silenced until
manually enabled.
Service or replace battery, or battery is not
installed in NXG-Vision
VISUAL INDICATORS
CONTROL SWITCHES
5 Alarm Silence
6N.I.R -
(Function #1)
N.I.R.
(Function #2)
Disables Audible Alarm function. Press and release to
disable Audible Alarm for 24 hours. Press and hold for 15
seconds to disable Audible Alarm indefinitely. Press and
hold for another 15 seconds to re-enable Audible Alarm
function.
Allows NXG-Vison capability to "Cold Start" Vdc power
from Battery Pack when AC line power is not present and
new or replacement Battery Pack is connected. When
new or replacement pack is connected, press and hold for
3 seconds
Allows for Output Vdc line power reset of Optical Network
Terminal when AC line power is present. Press and hold
for 3 seconds to reset/reboot Optical Network Terminal.
VISUAL AND AUDIBLE STATUS/ALARM SIGNALS
STATE VISUAL AUDIBLE DESCRIPTION
INDICATOR INDICATOR
Normal
ON
Battery
Replace
Battery
Battery
Missing
Low
Battery
System Status
Indicator On
DC Indicator On
Battery Indicator
On
Battery Indicator
On
DC Indicator
Flashes
1/2 second
audible
indicator every
15 min
1/2 second
audible
indicator 4
times per
minute
Operating under normal AC line
power load and conditions, charges
battery. Battery is connected and in
good condition.
AC line power failure or AC cord
disconnection. NXG-Vision is being
supplied with battery power.
Replace faulty or end of life battery
NXG-Vision is operating onAC line
power only without available stanby
power for outage scenario. When
battery is removed from unit,
battery indicator will illuminate after
15 sec.
Battery has reached equal to or
less than 30% remaining capacity
on battery discharge.
INSTALLATION
A. Slide NXG-Vision Battery Pack (FIGURE 2) onto NXG-Vision Power Supply/
Charger (FIGURE 1) until NXG-Vision Battery Pack becomes fully flush with
NXG-Vision Power Supply/Charger. You should hear a "click" when NXG-Vision
Battery Pack is fully seated.
B. Connect provided AC Power Cord to AC Input Connector on bottom of NXG-
Vision Power Supply/Charger.
C. Connect 3 Prong AC Power Cord Plug End into standard 3 Prong AC
Receptacle rated for NEMA 5-15 3 Prong AC Plug.
D. Verify "System Status" LED is "On" with Green illumination
E. Connect NXG-Vision to ONT (Optical Network Terminal)
F. Ensure "System Status" LED is the only illuminated LED on NXG-Vision. If
any additional LEDs are illuminated recheck NXG-Vision Battery Pack to make
sure it is fully seated and ensure that all wiring from NXG-Vision to ONT is
installed correctly as listed by ONT specific instructions.
BATTERY REPLACEMENT
As long as AC line power is available, NXG-Vision can resume operation while
battery is replaced.
PROCEDURE:
1. Remove the NXG-Vision Battery Pack by sliding off in opposite direction of
installation (FIGURE 4) and next follow "Installation Step A" above for installing
the new NXG-Vision Battery Pack
NOTE: Please follow all State, Federal, and International Regulations when
disposing or recycling Li Ion Battery Pack.
NOTE: PowerTec Solutions International reserves the right to change or correct
the contents of this document and does not assume any responsiblity for
ommissions or errors.
PowerTec Solutions International
Corporate Headquarters
1290 Harbor Court
Hollywood, FL 33019
P: 615-879-3326
E: [email protected]
Website: www.powertecsolutions.net
WARNINGS - Li Ion Battery Pack
DO NOT DISASSEMBLE BATTERY PACK
DO NOT DISPOSE OF IN FIRE
CHARGE ONLY WITH SPECIFIED CHARGER
DO NOT STORE IN TEMPERATURE OVER 65C
FCC NOTICE
This equipment has been tested and found to comply with the limit for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with these instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
tuning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures: (1) Reorient or relocate
the receiving antenna. (2) Increase the separation between the equipment and
receiver. (3) Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected. (4) Consult the dealer or an experienced
radio/TV technician for help.
CAUTION: Any changes or modifications could void the authority granted by the
FCC to operate this equipment.
Continuous Power Capacity