P+L Luralite Cento User manual

Luralite Cento & Luralite Professional
Please read these instructions carefully and store in a safe
place for future reference.
LURALITE
As part of the P+L brand of insect control products, Luralite is
an easy to service and highly effective decorative insect
control unit for use within front of house applications. Luralite
utilises highly effective UV tubes and is designed for use with a
high specification glupac™ glueboard. Two sizes of unit are
available - The compact Luralite Cento, (which is available in
four different colour options,) and the highly effective Luralite
Professional.
Contents of package
- 1 x Luralite flykiller
- 1 x glupac™ pheromone impregnated glueboard
- 2 x Screws and wall plugs
- 1 x PL-L compact 18W tube (fitted)
or
- 2 x 15W High powered insect attractive UV tubes (fitted)
WARNING - THIS APPLIANCE MUST BE EARTHED
INSECT CONTROL PRODUCTS
Luralite utilises high powered ultra violet tubes to attract flying
insects and retains the caught insects on a pheromone
impregnated glueboard for inspection or hygienic disposal.
POSITIONING
THIS UNIT IS FOR INDOOR USE ONLY.
Luralite should ideally be fixed around two metres above the
ground, preferably in the darkest place within the area to be
protected and is supplied with a two meter mains lead. Do
not position the unit close to windows, skylights or other
sources of light, or where it may be obscured by furniture,
doors or other obstacles. Ideally, Luralite units should be
visible from every part of the area to be protected.
INSTALLATION
PRIOR TO INSTALLATION, ENSURE THE POWER SUPPLY OF YOUR
MAINS OUTLET CORRESPONDS TO THAT MARKED ON THE
SPECIFICATION LABEL FOUND ON THE FLYKILLER.
Luralite should be fixed to the wall with the supplied wall
plugs and screws. Once installed in position, fit the glupac™
glueboard in position as described in the glueboard
replacement section of this document. Luralite has a plug
fitted to the mains lead and once installed in position, should
be plugged into the nearest mains outlet.
WARNING - THIS APPLIANCE MUST BE EARTHED
USING LURALITE
Luralite should ideally be in operation for 24 hours a day,
ensuring your premises are kept free of flying insects. Insects
are most attracted to Luralite at night when there is no
competition from daylight or other light sources.
CLEANING
ENSURE THAT THE FLYING INSECT KILLER IS DISCONNECTED
FROM THE MAINS BEFORE CLEANING.
It is recommended that cleaning is carried out regularly when
the glueboard is replaced. Once the glueboard is removed,
the unit should be thoroughly wiped down with a damp
cloth, removing any build up of dirt. Ensure the unit is
completely dry before reconnecting it to the power supply.
GUARANTEE
Luralite has a two year guarantee and if maintained as
recommended in these instructions should continue to work
for many years.* Use of non-approved consumables may
invalidate the guarantee. Ensure genuine glupac™
glueboards are used in conjunction with this product.
*Excludes tubes, glueboards and starters. Does not cover breakdown due to misuse,
incorrect operation or use in an incorrect application.
Glueboard Installation
Decorative Glueboard Insect Control
Luralite

Decorative Glueboard Insect Control
C2008
P+L Systems Ltd
Information provided on these instructions is modified and
updated from time to time. This is due to the constant
redevelopment of our products. As such, it is not intended that
you should rely on it or that it should form part of any contract.
P+L Systems Ltd
Ten St James Business Park
Grimbald Crag Court
Knaresborough
HG5 8QB UK
T +44 (0)800 988 5359
F +44 (0)1423 863 497
W www.pandlsystems.com
Starter Replacement Tube Replacement (Professional) Tube Replacement (Cento)
SPECIFICATION / REPLACEMENT PARTS
GLUEBOARD REPLACEMENT
BEFORE REPLACING THE GLUEBOARD, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED FROM THE
MAINS SUPPLY.
The glueboard should be replaced every month with a genuine glupac™ glueboard. Use of
non-approved glueboards may invalidate your guarantee.
To replace the glueboard…
1. Remove the used glupac™ glueboard by simply sliding it out from the top of the unit
and either retain for catch evaluation or dispose of it hygienically.
2. Remove the protective release paper from the new glupac™ glueboard.
3. Slowly slide the new glupac™ glueboard into position with the adhesive side facing
the tube(s).
Always ensure the selected genuine glupac™ glueboards are compatible with your unit,
available from your PCO or P+L Systems Ltd.
TUBE REPLACEMENT
BEFORE REPLACING THE TUBE(S), ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED FROM THE
MAINS SUPPLY.
To ensure the efficiency of Luralite in catching flying insects, the UV tube(s) should be replaced
annually. After twelve months the phosphor coating that emits the correct wavelength of UV
light has burnt away and the UV output is diminished substantially.
To replace the UV tube(s)…
Luralite Cento 1. Pull the tube gently from the tube holder until it un-clips.
2. Gently rotate the tube until it becomes free from the tube support.
3. Reverse the process with the replacement tube.
Luralite Professional 1. Rotate the tube through 90 degrees.
2. Gently pull the tube away from the unit.
3. Reverse the process with the replacement tube.
STARTER REPLACEMENT
BEFORE REPLACING THE STARTER(S), ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED FROM THE
MAINS SUPPLY.
The starter(s) provide(s) an extra spark to initially light the UV tube(s). Starter(s) wear out and
should be replaced at the same intervals as the UV tube(s).
To replace the starter(s)…
1. Remove the glueboard from the units described above.
2. Rotate the starter anti-clockwise.
3. Pull the starter free from the unit.
Luralite
R1 01/08
Unit Luralite Cento Unit Luralite Professional
Voltage 230V ~ 50Hz Voltage 230V ~ 50Hz
Dimensions(mm) 465 x 170 x 200 Dimensions(mm) 730 x 210 x 200
Coverage 25 Sq. Metres Coverage 50 Sq. Metres
Weight 1.5 Kg Weight 2.5 Kg
Light Output 18W Light Output 30W
Tubes 1 x I815 Tubes 2 x I616
Starter 1 x I154 Starter 2 x I154
Glueboards (x6) INL118 Glueboards (x6) INL121
Wall Fixing points 190mm Wall Fixing Points 380mm
This manual suits for next models
1
Other P+L Insect Control Equipment manuals
Popular Insect Control Equipment manuals by other brands

AFCO
AFCO AF 950001-B Installation & operation instructions

Flextailgear
Flextailgear MAX REPEL user guide

BASETech
BASETech 1359485 operating instructions

INSECT-O-CUTOR
INSECT-O-CUTOR Ex Elite EX21 Instruction booklet

Rentokil
Rentokil Lumnia Suspended US instruction manual

Neher
Neher DF-2016-1 Application notes