PR 5725 User manual

5725
SIGNALS THE BEST
Programmable
frequency indicator
No. 5725V100-UK
From ser. no. 100687001

(1218)
PR electronics A/S tilbyder et bredt program af analoge og digitale
signalbehandlingsmoduler til industriel automation. Programmet
består af Isolatorer, Displays, Ex-barrierer, Temperaturtransmittere,
Universaltransmittere m. Vi har modulerne, du kan stole på i selv
barske miljøer med elektrisk støj, vibrationer og temperaturudsving,
og alle produkter opfylder de strengeste internationale standarder.
Vores motto »Signals the Best« er indbegrebet af denne loso –
og din garanti for kvalitet.
PR electronics A/S offers a wide range of analogue and digital
signal conditioning devices for industrial automation. The product
range includes Isolators, Displays, Ex Interfaces, Temperature
Transmitters, and Universal Devices. You can trust our products
in the most extreme environments with electrical noise, vibrations
and temperature uctuations, and all products comply with the
most exacting international standards. »Signals the Best« is the
epitome of our philosophy – and your guarantee for quality.
PR electronics A/S offre une large gamme de produits pour le
traitement des signaux analogiques et numériques dans tous
les domaines industriels. La gamme de produits s’étend des
transmetteurs de température aux afcheurs, des isolateurs aux
interfaces SI, jusqu’aux modules universels. Vous pouvez compter
sur nos produits même dans les conditions d’utilisation sévères,
p.ex. bruit électrique, vibrations et uctuations de température.
Tous nos produits sont conformes aux normes internationales les
plus strictes. Notre devise »SIGNALS the BEST« c’est notre ligne
de conduite - et pour vous l’assurance de la meilleure qualité.
PR electronics A/S verfügt über ein breites Produktprogramm
an analogen und digitalen Signalverarbeitungsmodule für die in-
dustrielle Automatisierung. Dieses Programm umfasst Displays,
Temperaturtransmitter, Ex- und galvanische Signaltrenner, und
Universalgeräte. Sie können unsere Geräte auch unter extremen
Einsatzbedingungen wie elektrisches Rauschen, Erschütterungen
und Temperaturschwingungen vertrauen, und alle Produkte von
PR electronics werden in Übereinstimmung mit den strengsten
internationalen Normen produziert. »Signals the Best« ist Ihre
Garantie für Qualität!
DK
UK
FR
DE

5725V101-IN 1
PROGRAMMABLE FREQUENCY INDICATOR
5725
CONTENTS
Warning .............................................................................. 4
Safety instructions.............................................................. 5
EC declaration of conformity ............................................. 7
Front and back layout ........................................................ 8
Application ......................................................................... 9
Technical characteristics.................................................... 9
Mounting / installation........................................................ 9
Applications........................................................................ 10
Electrical specifications...................................................... 11
Order: 5725 ........................................................................ 11
Sensor error indication, inside and outside range............. 15
Connections ....................................................................... 16
Block diagram .................................................................... 17
Routing diagram for 5725A................................................ 19
Routing diagram for 5725D................................................ 21
Scrolling help texts............................................................. 22
Configuration / operating the function keys ...................... 24
Graphic depiction of the relay function setpoint .............. 26

2 5725V101-IN
SYMBOL IDENTIFICATION
Triangle with an exclamation mark: Warning / demand. Potentially
lethal situations.
The CE mark proves the compliance of the device with the essential
requirements of the directives.
WARNING
This device is designed for connection to hazardous electric
voltages. Ignoring this warning can result in severe personal
injury or mechanical damage. To avoid the risk of electric shock
and fire, the safety instructions of this manual must be observed
and the guidelines followed. The specifications must not be
exceeded, and the device must only be applied as described
in the following. Prior to the commissioning of the device, this
manual must be examined carefully. Only qualified personnel
(technicians) should install this device.
If the equipment is used in a manner not specified by the
manufacturer, the protection provided by the equipment may be
impaired.
WARNING
Until the device is fixed, do not connect hazardous voltages to
the device.
The following operations should only be carried out on a
disconnected device and under ESD safe conditions:
Troubleshooting the device.
Repair of the device must be done by PR electronics A/S
only.
GENERAL
HAZARD-
OUS
VOLTAGE

5725V101-IN 3
SAFETY INSTRUCTIONS
DEFINITIONS
Hazardous voltages have been defined as the ranges: 75 to 1500 Volt DC, and
50 to 1000 Volt AC.
Technicians are qualified persons educated or trained to mount, operate, and
also troubleshoot technically correct and in accordance with safety regulations.
Operators, being familiar with the contents of this manual, adjust and operate
the knobs or potentiometers during normal operation.
RECEIPT AND UNPACKING
Unpack the device without damaging it. The packing should always follow the
device until this has been permanently mounted. Check at the receipt of the
device whether the type corresponds to the one ordered.
ENVIRONMENT
Avoid direct sunlight, dust, high temperatures, mechanical vibrations and shock,
as well as rain and heavy moisture. If necessary, heating in excess of the stated
limits for ambient temperatures should be avoided by way of ventilation.
All devices fall under Installation Category II, Pollution Degree 1, and Insulation
Class II.
MOUNTING
Only technicians who are familiar with the technical terms, warnings, and
instructions in the manual and who are able to follow these should connect the
device.
Should there be any doubt as to the correct handling of the device, please
contact your local distributor or, alternatively,
PR electronics A/S
www.prelectronics.com
Mounting and connection of the device should comply with national legislation
for mounting of electric materials, i.e. wire cross section, protective fuse, and
location. Descriptions of Input / Output and supply connections are shown in
the block diagram and side label.

4 5725V101-IN
The following apply to fixed hazardous voltages-connected devices:
The max. size of the protective fuse is 10 A and, together with a power
switch, it shall be easily accessible and close to the device. The power
switch shall be marked as the disconnecting unit for the device.
UL INSTALLATION REQUIREMENTS
For use on a flat surface of a type 1 enclosure.
Use 60/75°C copper conducters only.
Enclosure rating (face only).................... Type 4X, UL50E
Max. ambient temperature..................... 60°C
Max. wire size, pins 41...46.................... AWG 30-16
Max. wire size, others ............................ AWG 30-12
UL file number........................................ E248256
CALIBRATION AND ADJUSTMENT
During calibration and adjustment, the measuring and connection of external
voltages must be carried out according to the specifications of this manual. The
technician must use tools and instruments that are safe to use.
NORMAL OPERATION
Operators are only allowed to adjust and operate devices that are safely fixed
in panels, etc., thus avoiding the danger of personal injury and damage. This
means there is no electrical shock hazard, and the device is easily accessible.
CLEANING
When disconnected, the device may be cleaned with a cloth moistened with
distilled water.
LIABILITY
To the extent the instructions in this manual are not strictly observed, the
customer cannot advance a demand against PR electronics A/S that would
otherwise exist according to the concluded sales agreement.

5725V101-IN 5
EC DECLARATION OF CONFORMITY
As manufacturer
PR electronics A/S
Lerbakken 10
DK-8410 Rønde
hereby declares that the following product:
Type: 5725
Name: LED frequency / pulse converter
is in conformity with the following directives and standards:
The EMC Directive 2004/108/EC and later amendments
EN 61326-1 : 2006
For specification of the acceptable EMC performance level, refer to the
electrical specifications for the device.
The Low Voltage Directive 2006/95/EC and later amendments
EN 61010-1 : 2001
Rønde, 17 February 2011 Kim Rasmussen
Manufacturer’s signature

6 5725V101-IN
FRONT AND BACK LAYOUT
Picture 1: Front of 5725.
Picture 2: Back of 5725.

5725V101-IN 7
PROGRAMMABLE FREQUENCY INDICATOR
5725
• Frequencies from 0.001 Hz to 50 kHz
• Input for various sensors; NPN, PNP, Contact,
Namur, S0, Tacho and TTL
• 2 SPDT relays and analogue output
• 4-digit, 14-segment easily readable LED display
• Universal supply voltage
Application
• 5725isadigitalindicatorforreadoutoffrequencysignalsandpulsesignals.
• Typicalapplicationsareindicationandconversionofprocessspeed
measurements and flow rate.
• Theindicatorcanalsobeusedformeasuringthepassingtimeone.g.a
conveyor line, as the 5725 can handle period time measurements.
• Processcontrolispossibleasthetype5725Dcontains2pairsofpotential-
free change-over relays and an analogue output.
• ThedisplayoffersIP65protectionfromthefrontandthesplash-proofcover-
PR type 8335 - can be used against atmospheres and liquids.
Technical characteristics
• 4-digitLEDindicationwith13.8mm14-segmentcharactersfora
-1999...9999 display readout with programmable decimal point.
• RelayON/OFFindicationviafrontLED’s.
• Variousinputsensortypesandcustomcurrentandvoltagetriglevelscanbe
selected via the programming menu.
• InputandsupplyofNPNandPNPproximityswitchesispossiblefromthe
input terminals.
• Amenuitemallowstheusertominimisetheinstallationtesttimefortherelay
outputs by activating or deactivating each relay independently of the input
signal.
Mounting / installation
•Panelmountedindicator,48x96mmwhichobtainsIP65(type4X)whenusing
the rubber gasket provided.
• Allstandardoperationalparameterscanbeadjustedtoanyapplicationby
way of the front function keys.
• Helptextsineightdifferentlanguagesareavailableandcanbeselectedviaa
menu item.

8 5725V101-IN
CONNECTIONS
+
-
26
25
24
23
22
21
12
11
32
31
S0
44
43
42
41
1 2
1 2
∼
∼
∼TTL
1 2
Output signals:
Relay 1
Analogue, 0/4...20 mA
Special trig
current & voltage
Namur Tacho
Supply:
21.6...253 VAC
or
19.2...300 VDC
S0 PNP NPN Contact
(NPN)
+ Sup + Sup
TTL
Input signals:
+ Sup 5...17 V
+ Input
Input gnd
tacho
Relay 2

5725V101-IN 9
Electrical specifications
Environmental conditions:
Specifications range.................................... -20°C to +60°C
Storage temperature ................................... -40°C to +85°C
Calibration temperature............................... 20...28°C
Relative humidity......................................... < 95% RH (non-cond.)
Protection degree........................................ IP20
Installation in pollution degree 2 & overvoltage category II.
Mechanical specifications:
Dimensions (H x W x D) .............................. 48 x 96 x 120 mm
Cutout dimensions ...................................... 44.5 x 91.5 mm
Protection degree (mounted in panel)......... IP65 / Type 4X, UL50E
Weight ......................................................... 230 g
Wire size, pin 11-12 & 41-44, max.............. 1 x 1.5 mm2/
AWG 30...16 stranded wire
Wire size, others, max................................. 1 x 2.5 mm2/
AWG 30...12 stranded wire
Terminal connection .................................... Spring-cage
Common electrical specifications:
Supply voltage, universal ............................ 21.6...253 VAC, 50...60 Hz
or 19.2...300 VDC
Max consumption, 5725A / 5725D ............. 2.8 W / 3.6 W
Isolation voltage, test / operation ............... 2.3 kVAC / 250 VAC
Signal / noise ratio ...................................... > 60 dB
Order: 5725
Type Version
5725 Standard...................: A
Analogue output and 2 relays ..: D
8335 = Splash proof front
Accessories:

10 5725V101-IN
Input:
General:
Frequency range, F/I conversion function ..... 0.001 Hz to 50 kHz
Time range, Period time function................ 999.9 sec to 20 µsec
Response time (0...90%, 100...10%) ........... < 1 period + 100 msec
Low cut off frequency ................................. 0.0009 Hz
Low cut off period time............................... 1111 sec
Max. frequency, with input filter ON ........... 50 Hz
NAMUR input - acc. to EN 60947-5-6:
Trig-level LOW............................................. ≤ 1.2 mA
Trig-level HIGH ............................................ ≥ 2.1 mA
Input impedance ......................................... 1 kΩ / < 1.5 nF
Breakage detection ..................................... ≤ 0.1 mA
Short-circuit detection................................. ≥ 6.9 mA
Sensor supply - pin 44, fixed...................... 8.3 V
Tacho input:
Trig-level LOW............................................. ≤ - 50 mV
Trig-level HIGH ............................................ ≥ + 50 mV
Input impedance ......................................... ≥ 100 kΩ / < 1.5 nF
Max. input voltage....................................... 80 VAC pp
Sensor supply - pin 44, programmable ..... 5 -17 V / 20 mA
NPN / PNP input:
Trig-level LOW............................................. ≤ 4.0 V
Trig-level HIGH ............................................ ≥ 7.0 V
Input impedance ......................................... 3.48 kΩ / < 1.5 nF
Sensor supply - pin 44, programmable ..... 5 -17 V / 20 mA
Accuracy values
Specification
Absolute
accuracy
Temperature
coefficient
Input to Display & Relays ≤±0.05%
≤±0.01% / °C
Input to Analogue Output ≤ ±0.1%
EMC immunity influence .................................. < ±0.5% of span
Extended EMC immunity:
NAMUR NE 21, A criterion, burst .................... < ±1% of span

5725V101-IN 11
TTL input:
Trig-level LOW............................................. ≤ 0.8 VDC
Trig-level HIGH ............................................ ≥ 2.0 VDC
Input impedance ......................................... ≥ 100 kΩ / < 1.5 nF
Sensor supply - pin 44, programmable ..... 5 -17 V / 20 mA
S0 input acc. to DIN 43864:
Trig-level LOW............................................. ≤ 2.2 mA
Trig-level HIGH ............................................ ≥ 9.0 mA
Input impedance ......................................... 758 Ω / < 1.5 nF
Sensor supply - pin 44, fixed...................... 17 V
Special voltage input:
User programmable trig-levels.................... -0.05...6.50 V
Hysteresis, min............................................ 50 mV
Input impedance, selectable:
High Z.................................................... ≥100 kΩ / < 1.5 nF
Pull up and pull down............................ 3.48 kΩ / < 1.5 nF
Sensor supply - pin 44, programmable ...... 5 -17 V / 20 mA
Special current input:
User programmable trig-levels.................... 0.0...10.0 mA
Hysteresis, min............................................ 0.2 mA
Input impedance ......................................... 1 kΩ / < 1.5 nF
Sensor supply - pin 44, programmable ..... 5 -17 V / 20 mA
Output:
Display:
Display readout ........................................... -1999...9999 (4 digits)
Decimal point .............................................. Programmable
Digit height .................................................. 13.8 mm
Display updating ......................................... 2.2 times / sec.
Input frequency outside range &
Namur input sensor error is indicated by....... Explanatory text

12 5725V101-IN
Output:
Current output (5725D):
Programmable signal ranges ...................... 0...20, 4...20 &
20...0, 20...4 mA
Load (max.).................................................. 20 mA / 800 Ω / 16 VDC
Current limit................................................. ≤ 28 mA
Load stability............................................... ≤ 0.01% of span / 100 Ω
Programmable response time..................... 1.0...60.0 sec
Sensor error indication, at Namur input:
selectable .............................................. 0 / 3.5 / 23 mA / none
Output limitation at outside range:
on 4...20 and 20...4 mA signals............. 3.8...20.5 mA
on 0...20 and 20...0 mA signals............. 0...20.5 mA
Relay outputs (5725D):
Relay function.............................................. Setpoint
Hysteresis, in % / display counts ............... 0.1...100% / 1...9999
On and Off delay......................................... 0...3600 sec
Power On delay........................................... 1.0...60.0 sec
Sensor error action...................................... Make / Break / Hold
Max. voltage................................................ 250 VRMS
Max. current ................................................ 2 A / AC
Max. AC power ........................................... 500 VA
Max. current at 24 VDC............................... 1 A
Approvals:
EMC 2004/108/EC ...................................... EN 61326-1
LVD 2006/95/EC.......................................... EN 61010-1
UL, Standard for Safety .............................. UL 61010-1
GOST R
Marine:
Det Norske Veritas, Ships & Offshore ......... Stand. f. Certific. No. 2.4

5725V101-IN 13
Sensor error indication, inside and outside range
Input ”out of range” indication
Valid measurement range: Out of range limit Display readout
F to I function:
0.001 Hz to 50 kHz
< 0.0009 Hz
- equals ”Low cut off time”
”0” or ”IN.LO” if 0% input
value is set different from ”0”
> 50.5 kHz ”IN.HI”
Period time function:
20 µs to 999.9 s
>1111 s (18 min. 31 sec.)
- equals ”Low cut off time” ”IN.LO”
< 19.8 µs ”IN.HI”
! Error indications in the display blink once a second. The help text explains the error.
Sensor error indication in 5725, only available for NAMUR input:
Condition Out of range
limit
Relay
behaviour
Analogue
output value
Display
redaout
Sensor input
type = NAMUR
and sensor error
detection = ON
> 6.9 mA Set to user
defined value:
HOLD. ACTIVE.
DEACTIVE or NONE
Set to user-
defined value
(23, 0, 3.5 mA
or NONE)
”SE.SH”
< 0.1 mA ”SE.BR”
Display out of range Indication
Valid display value range: Out of range limit Display readout
-1999 to 9999 < -1999 ”-1.9.9.9.” - flashing
> 9999 ”9.9.9.9.” - flashing
Hardware error indication
Error explanation Error cause Display readout
Error in internal communication
(SPI etc.)
Permanent error in inter-
communication between
microcontrollers
”HW.ER”
Error in checksum test of the
configuration in RAM Error in RAM ”RA.ER”
Error in checksum test of the
configuration in EEPROM Error in EEPROM ”EE.ER”
Error in OK check or checksum
test of the calibration data in
FLASH
Error in FLASH or
Calibration has not been per-
formed or Calibration data in
FLASH are corrupt
”NO.CA”

14 5725V101-IN
31 32
41 42 43 44 45 46
41 42 43 44 45 46
41 42 43 44 45 46
41 42 43 44 45 46 41 42 43 44 45 46 41 42 43 44 45 46
41 42 43 44 45 46 41 42 43 44 45 46
mA
11 12
R2
R1
21 22 23 24 25 26
S0
- +
+ Sup+ Sup
+ Sup 5-17V + Sup 5-17V
∼
41 42 43 44 45 46
TTL
TTL
+ Sup 8.3V + Sup 17V +
+ Sup 5-17V + Sup 5-17V
+
+
Special current Special voltage Tacho
S0Namur
PNP NPN Contact (NPN)
Current
Inputs:
Output:
Supply:
Relays
CONNECTIONS

5725V101-IN 15
I+
21
22
23
11
12
31
32
24
25
26
CPU
EEPROM
5725A & D
1 2 3 4
44
46
45
43
42
41
R1
R2
mA
VREG
5...17 V
BLOCK DIAGRAM
I
Output
Common
Relay 1 N.O.
Relay 1 N.C.
Common
Relay 2 N.O.
Relay 2 N.C.
Supply
Supply
21.6...253 VAC
or
19.2...300 VDC
Option D
Gnd.
Option D
fin
Freq.
detector

16 5725V101-IN
----
0000
9999
1 2
3
IN
1 2
PASS
XV
100.0
LANG
TXT 0 . . . 7
3
CZ
ES
IT
SE
FR
DE
DK
UK
3
1 2
3
TXT 21 TXT 22. . . 2 9
XmA
TACH
S0
NAMU
TTL
NPN
PNP
-0.05
6.45
1 2
TR.LO
TXT 31
3
0.00
6.50
1 2
TR.HI
TXT 33
HI.Z
PL.UP
PL.DN
1 2
Z.IN
TXT 34 . . . 3 6
3 3 5.0
17.0
1 2
S.SUP
TXT 37
3
3
0.0
9.80
1 2
TR.LO
TXT 31
0.2
10.0
1 2
TR.HI
TXT 33
3 3
3
3
3
3
3
3
3
*1
Only visible if password is enabled
(E.PAS = YES)
*1
*2
*3 Password 5000...9999:
FastSet and Relay Test features disabled.
(FastSet menus show the actual setpoints).
”Start”
”Monitor”
Hold
(∼3sec.)
Power up
”Start”
ROUTING DIAGRAM FOR 5725A
If no key is activated for 2 minutes, the display returns to default state
”Monitor” without saving configuration changes.
1Increase value / choose next parameter
2Decrease value / choose previous parameter
3Accept the chosen parameter and go to the next menu
Hold 3Back to previous menu / return to default state ”Monitor” without
saving.

5725V101-IN 17
1 2
IN.UN
TXT 38/39
0.000
49.9
1 2
IN.LO
HZ/KHZ
3
TXT 40/41
0.001
50.0
1 2
IN.HI
HZ/KHZ
3
TXT 44/45
NO
YES
1 2
FILT
TXT 48
31111
111.1
11.11
1.111
1 2
DEC.P
TXT 49
3-1999
9999
1 2
DI.LO
TXT 50
3-1999
9999
1 2
DI.HI
TXT 51
3
HZ
S
3
0.020
999.8
1 2
IN.LO
mS/S
3
TXT 42/43
0.021
999.9
1 2
IN.HI
mS/S
3
TXT 46/47
3
1 2
E.PAS
TXT 7 7
NO 3
YES 3
1 2
N.PAS
TXT 7 8
0
9999 3
*4 *
9
*5
*1 *3
*8
*9 Minimum IN.HI value is automatically
limited to 1 display count above IN.LO.
”Start”
”Start”
Displays either Hz/kHz or s/ms for 1 sec.
before actual value is displayed.
When value hits digit-limit while scrolling,
either Hz/kHz or s/ms is displayed again for
1 sec. to show the user that the new range
is active.
*4
Only visible if password is enabled
(E.PAS = YES)
*1
*2
*3 Password 5000...9999:
FastSet and Relay Test features disabled.
(FastSet menus show the actual setpoints).
*5
*6
*7
Only visible if max. (IN.LO,IN.HI) value
is ≤ 50 Hz (F/I) or ≥ 20 ms (Period time)
Default if visible = YES, else deactivated.
Range depends on selected display scaling.

18 5725V101-IN
---- F.SET
REL1
REL2 3
1 2
SETP
-1999
9999 3
1 2
0000
9999
1 2
3
IN
1 2
PASS
XV
TXT 18 TXT 19/20
0.0
100.0
3
1 2
100.0
LANG
TXT 0 . . . 7
3
CZ
ES
IT
SE
FR
DE
DK
UK
3
1 2
1 2
3
TXT 21 TXT 22. . . 2 9
XmA
TACH
S0
NAMU
TTL
NPN
PNP
-0.05
6.45
1 2
TR.LO
TXT 31
3
0.00
6.50
1 2
TR.HI
TXT 33
HI.Z
PL.UP
PL.DN
1 2
Z.IN
TXT 34 . . . 3 6
3 3 5.0
17.0
1 2
S.SUP
TXT 37
3
3
0.0
9.8
1 2
TR.LO
TXT 31
0.02
10.0
1 2
TR.HI
TXT 33
3 3
3
3
3
3
3
3
3
PERC
DISP
1 2
3
REL.U
TXT 52/53
SKIP
1 2
3
REL.1
TXT 5 4 . . . 5 3
TXT 6 7 . . . 6 9
SET
OFF
3
3
0.0
100.0
1 2
3
SETP
TXT 57
if REL.U
= PERC
if REL.U
= DISP
-1999
9999
1 2
3
SETP
TXT 57
INCR
DECR
1 2
3
ACT1
TXT 58/59
INCR
DECR
1 2
3
ACT1
TXT 58/59
0.1
100.0
1 2
3
HYS1
TXT 60
1
9999
1 2
3
HYS1
TXT 60
if REL.U
= PERC
if REL.U
= DISP
1 2
ERR1
TXT 61...64
HOLD
ACTI
DEAC
NONE
3
*2 *2 *3
*1
*7
*6
Fast setpoint adjustment and relay test
1 Increase setpoint
2 Decrease setpoint
3 Save and exit the menu
1 and 2simultaneously =
relay changes state
Same procedure
for REL2!
”Start”
”Monitor”
Hold
(∼3sec.)
Power up
”Start”
”Start” ”Start”
ROUTING DIAGRAM FOR 5725D
If no key is activated for 2 minutes, the display returns to default state ”Monitor”
without saving configuration changes.
1Increase value / choose next parameter
2Decrease value / choose previous parameter
3Accept the chosen parameter and go to the next menu
Hold 3Back to previous menu / return to default state ”Monitor” without saving.
Other manuals for 5725
2
Table of contents
Other PR Touch Panel manuals