M2I TOPRW0700WD-IO User manual

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
1 / 22
M2I Corporation
Industrial HMI Touch Panel
TOPRW0700WD-IO
Hardware Manual
Thank you for purchasing the industrial HMI touch panel series of M2I corporation.
Please read this manual carefully to know installing, wiring operating this equipment for safe use of this
product.

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
2 / 22
Contents
Contents....................................................................................................................................................................................................................... 2
Chapter 1 Safety Precautions............................................................................................................................................................................. 3
Chapter 2 Overview ................................................................................................................................................................................................ 5
2.1 Introduction of Products.............................................................................................................................................. 5
2.2 Package Contents............................................................................................................................................................ 5
2.3 Explanation of Model Name ...................................................................................................................................... 5
Chapter 3 General Specifications ..................................................................................................................................................................... 6
3.1 Power Specifications ...................................................................................................................................................... 6
3.2 Memory Specifications.................................................................................................................................................. 6
3.3 Interface and Functional Specification .................................................................................................................. 6
3.4 Environment Specifications......................................................................................................................................... 6
3.5 Structure Specifications ................................................................................................................................................ 6
Chapter 4 Part Names and General Specifications.................................................................................................................................. 7
4.1 TOPRW0700WD-IO......................................................................................................................................................... 7
4.2 Product Dimension ......................................................................................................................................................... 7
4.3 Part Names and General Specifications................................................................................................................ 8
4.4 Rear Part Names and Specifications ...................................................................................................................... 8
Chapter 5 External Device Interface ............................................................................................................................................................... 9
5.1 Serial Communication Specifications ..................................................................................................................... 9
5.2 Ethernet Communication Specifications .............................................................................................................10
5.3 USB Specifications.........................................................................................................................................................11
Chapter 6 I/O Interface Specification...........................................................................................................................................................11
6.1 Digital Input .....................................................................................................................................................................11
6.2 Digital Output .................................................................................................................................................................12
6.3 Analog Input / Output Specification....................................................................................................................13
6.4 RTD Input ..........................................................................................................................................................................14
Chapter 7 Installation ..........................................................................................................................................................................................17
7.1 Installation Requirements ..........................................................................................................................................17
7.2 Installation Procedure..................................................................................................................................................17
Chapter 8 Wiring ...................................................................................................................................................................................................19
8.1 Power Wiring ...................................................................................................................................................................19
8.2 Ground Wiring ................................................................................................................................................................20
Chapter 9 Maintenance ......................................................................................................................................................................................21
9.1 Cleaning the Display ....................................................................................................................................................21
9.2 Periodic Check Points..................................................................................................................................................21
9.3 Problems with the Device..........................................................................................................................................21
9.4 Setting System Recovery Mode..............................................................................................................................21
Chapter 10 Products Label................................................................................................................................................................................22

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
3 / 22
Chapter 1 Safety Precautions
■Before using the product
To use the product safely and effectively, please read the contents of this manual thoroughly before use. Please
keep to the safety precaution, for it is to prevent accidents and potential danger from occurring. Safety
precaution is classified into ‘Warning’ and ‘Caution’ and their meanings are as follows. Also the indicated
illustrations on the product and in the manual have the following meanings.
Violating the instruction may result in serious personal injury or death.
Violating the instruction may result in slight personal injury or product damage.
Be cautious, for danger may be present.
Be cautious, for there is a possibility of an electric shock.
■General Precautions
Do not press the screen with a hard or sharp object (awl, screwdriver, pen) with too strong a force.
It may cause malfunction of touch due to damage of the front sheet.
Do not use or store in an environment with high vibration.
Do not allow foreign objects such as water, liquids, or metal powders to enter the product. This may cause
breakage or electric shock.
Do not allow foreign objects such as water, liquids, or metal powders to enter into the product.
Use the radio or mobile phone at least 30cm away from the main unit.
Two or fewer bright spots may appear on the LCD screen, and certain areas may appear brighter, but this is
not a defect in LCD characteristics.
Do not store or operate in direct sunlight. Direct sunlight can change the properties of the LCD.
Do not touch an adaptor or power code with wet hands. It can cause electric shock.
Do not use this product in explosive environments with flammable liquid, gas, or dust.
If the product needs long-term storage without using, avoid direct sunlight and keep dry condition.
After this product is installed, the general user should only touch the part exposed on the front during
operation.
■Design Precautions
For protecting whole control system from outer power input or malfunction of product, protection circuit
must be installed outside of product.
Physical protection devices as emergency switch, limit switch, or motion interlock circuit and others to
prevent a critical damage of whole system’s safety and human accident from the product’s malfunction.
When computers or other outer devices control (operation mode change) the product, set interlock in
sequence program to protect from any communication errors.
Input/output signals or communication cables must have at least 100mm(3.94inch) distance from power
cable or high-tension wire. Especially communication cables must be set apart from power cables.
■Wiring Precautions
Be sure the wiring is done correctly by checking the product’s rated voltage and the terminal layout.
Incorrect wiring could result in fire, damage or malfunctions.
Tighten the terminal screw with the specified torque. If the screws of terminal are loose, it could result in

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
4 / 22
short circuit, fire, malfunctions. FG Terminal must be used a dedicated ground. Not doing so could result in
malfunctions.
a. Grounding should be the Class 3 grounding. The cable for grounding should be more than 4㎟.
b. grounding point be closed to the products and make short the distance to the ground cable if possible.
■Installation Precautions
Do not install the location which exceeds allowed temperature. Product can be damaged or shorten the life.
Especially Install environment as below should be avoided.
Do not Install product to the place which the ambient temperature is out of limits, from -10℃to 50℃or on the surface
of control board which high pressure equipment is installed.
Do not install to the place where strong shock or vibration continuously have impacted on product.
If the product is left without using in long-term, it must be recharged and stored in room temperature.
The space between back of product and back of control board must be more than 100mm for maintenance
and ventilation.
Use the product indoors only.
Use the product under 2000M altitute.
Power cable’s length should be 3M(10ft) or shorter.
■Disposal Precautions
When you dispose of product and battery, please treat it as industrial waste. It can create poisonous substances
or explosion.
■Cell Type Battery Specifications and Exchange
Mounted on mainboard Model MS920SE Battery is not replaced by the user. If the battery has run out of service,
please contact our Customer Support Center for replacement and inspection.
Item
Content
Battery Voltage
DC 3V
Battery Model
MS920SE (lithium / Rechargeable)
Battery lifetime
Permanent (In case of ambient temperature 25℃)
*Depending on the model specifications are subject to change.
■All field-wiring connections to this unit shall be from Limited Voltage / Limited Current, below 24Vdc
isolated secondary source with an output fuse, or Class 2.

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
5 / 22
Chapter 2 Overview
2.1 Introduction of Products
This industrial HMI touch panel is an industrial control device required in industrial field. It is a device based on
RS-232C and RS-422/485, Ethernet which is used for the basic purpose of communication with another device
(PLC).
2.2 Package Contents
The components of the product are as follows.
Before using the product, please check that all of the following components are included.
Item
Figure
Quantity
Process Module
And
Manual
각1
Clamp
4
Power Connector
1
I/O Connector (20 Pin)
2
I/O Connector (10 Pin)
2
Accessories
(Sold separate)
USB Memory
USB Cable
SD Card
Front Protect Sheet
User Options
2.3 Explanation of Model Name
TOPRW
□□
□□
□
□
-□□
Series
Display Size
Option
Resolution
Power
Series
07: 7.0”
00: Standard
W: WVGA (800*480)
D: DC
-IO: Standard

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
6 / 22
Chapter 3 General Specifications
3.1 Power Specifications
Input Voltage
DC24V
Input Voltage Range
DC 20~28V
Consumption Power
15W 이하
Voltage endurance
DC 24V, Within 10 ㎳
Insulation Resistance
500V DC, 10 ㏁
3.2 Memory Specifications
Screen Memory
128MB
Backup Memory
512KB: System buffer (10K Word), Including Alarm/Log/Recipe
Backup Period
Permanent
Real Time Clock
Built in (by Battery)
3.3 Interface and Functional Specification
I/O Voltage and Current Range
Maximum Delay Time
Resolution
Insulation
Digital Input
ON: 11.0Vdc ~ 28.8Vdc / Max. 6mA
OFF: 5Vdc 이하 / Max. 6mA
OFF - ON: Max. 0.1ms
ON - OFF: Max. 0.5ms
N/A
Photocoupler
Digital Output
11.0Vdc ~ 28.8Vdc / 0.5A
ON: Max. 0.3ms, OFF: Max. 0.5ms
N/A
Analog Input
AIC: 0 ~ 20mA, AIV: 0 ~ 5Vdc,
RTD: PT100 (*-200°C ~ +850°C)
TBD
16 bit
Capacitive
Analog Output
AOC: 0 ~ 20mA, AOV: 0 ~ 5Vdc
TBD
16 bit
* While using digital input port, electrical noise can be flowed. A digital filter is integrated for preventing, and this can cause
maximum 0.5ms input delay.
3.4 Environment Specifications
Operation Temperature (℃)
-10 ~ +50
Storage Temperature (℃)
-20 ~ +60
Operation Humidity (%RH)
0 ~ 90 (No dew)
Atmosphere
No corrosive gas
Vibration Endurance
Amplitude: 10≤F<25 ㎐(2G) X,Y,Z each direction(for 30 minutes)
Noise Immunity
1000Vp-p(Pulse width 1 ㎲)
Static Electricity Discharge
Connective discharge from EN61000-4-2: ±4 ㎸
Shock Endurance
10G X,Y,Z each direction(for 3 times)
Surge Voltage
500V(Line-Line)
Ground Connection
Class 3(Under 100Ω)
Protection Classification
Conform to IP65
3.5 Structure Specifications
Weight(Kg)
0.8
Cooling System
Natural Air Circulation
Case Material
PC(Flameless)

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
7 / 22
Chapter 4 Part Names and General Specifications
4.1 TOPRW0700WD-IO
4.2 Product Dimension
Model Name
F1(mm)
F2(mm)
S1 (mm)
S2 (mm)
R1(mm)
R2(mm)
TOPRW0700WD-IO
212
145
62.5
56.5
194.2
124.9

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
8 / 22
4.3 Part Names and General Specifications
Num.
Name
Description
1
LCD
TFT 16M Color LCD
2
Touch Panel
Analog Touch
3
USB OTG Cover and Power LED
Front USB OTG Cover and Power LED
4.4 Rear Part Names and Specifications
No.
Part
Form
Description
1
Rubber Packing
-
Silicone Gasket for Impact Buffering and IP Securing for Wall
Mounting
2
Status LED
3
Status of Power, Communication and CPU
3
COM1 Connector
DSUB9
RS-232C Serial Comm. with PLC
4
COM2 Connector
DSUB9
RS-232C/422/485 Serial Comm. with PLC
(Switchable the Comm. Via Software)
5
ETHERNET Connector
RJ45
10BASE-T/100BASE-TX, Auto-MDIX
6
USB Connector
MINI USB Type AB
USB Connectors for Storage Options
7
Power Input Terminal
TB 5mm 3P
Power Supply of Main Unit(DC 24V)
8
Digital Input Terminal
TB 3.5mm 20P
Digital Input Terminal Point
9
Digital Output Terminal
TB 3.5mm 20P
Digital Output Terminal Point
10
Analog I/O Terminal
TB 3.5mm 10P
Analog Input / Output Terminal
11
RTD Input Terminal
TB 3.5mm 10P
Analog RTD, PT100 Input Terminal
12
SD Card Slot
SD Card Slot
SD Card Insert Connector
13
Mode Switch
DIP Switch 2Digit
Set Up System Switch
14
Reset Switch
Tact Switch
System Reset Switch
15
Diagnose Connector
2mm 4P
Diagnose System (Manufacturer Only)

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
9 / 22
Chapter 5 External Device Interface
In order for the main unit to communicate with an external device, it is necessary to connect the two devices
by referring to the following.
5.1 Serial Communication Specifications
5.1.1 RS-232C
Items
Contents
Protocol
Full Duplex
Synch
Asynchronous
Communication Distance
About 15m
Type of Connection
1:1
Control Code
ASCII Code or HEXA Code
Transmission Speed
2400,4800,9600,19200,38400,57600,76800,115200 bps
Data Type
Data Bit
7, 8 bit
Parity Bit
NONE, ODD, EVEN Parity
Stop Bit
1, 2 bit
Modular Jack
DSUB 9pin
5.1.2 RS-422/485
Items
Contents
Protocol
Full Duplex/Half Duplex
Synch
Asynchronous
Communication Distance
About 500m
Type of Connection
1:N(N ≤31)
Control Code
ASCII Code or HEXA Code
Transmission Speed
2400,4800,9600,19200,38400,57600,76800,
115200 bps
Data Type
Data Bit
7, 8 bit
Parity Bit
NONE, ODD, EVEN Parity
Stop Bit
1, 2 bit
Modular Jack
DSUB 9pin
5.1.3 COM1 Connector pin number and Signal name
Type
Pin No.
Signal
Direction
Meaning
9Pin Female
1
NC
-
Not Available
2
RD(RxD)
Input
RS-232C Receive Data
3
SD(TxD)
Output
RS-232C Send Data
4
NC
-
Not Available
5
SG
-
Signal Ground
6
NC
Not Available
7
*1)Power
-
+5V, 0.2A
8
*2)GND
-
Power Ground
9
NC
Not Available
*1, *2) When need VCC for external equipment, use 7.VCC and 8.VCC GND that output is 0.2A

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
10 / 22
5.1.4 COM2 Connector pin number and Signal name
Type
Pin No.
Signal
Direction
Meaning
9Pin Female
1
RDA(RD+)
Input
RS-422/485 Receive Data (+)
2
RD(RxD)
Input
RS-232C Receive Data
3
SD(TxD)
Output
RS-232C Send Data
4
RDB(RD-)
Input
RS-422/485 Receive Data (-)
5
SG
-
Signal Ground
6
SDA(SD+)
Output
RS-422/485 Send Data (+)
7
NC
-
Not Available
8
NC
-
Not Available
9
SDB(SD-)
Output
RS-422/485 Send Data (-)
* Be sure to connect the RD and SD to the RS-232C communication line by crossing each other with a Twisted Pair Cable.
Please connect SG directly.
* SG must be connected directly.
* RS-422/485 communication line must use RDA and RDB as Twisted Pair Cable, SDA and SDB as Twisted Pair
Cable.
* Do not use shield wire of communication line as signal ground. It may cause communication failure.
5.2 Ethernet Communication Specifications
5.2.1 Ethernet
Items
Contents
Ethernet Method
IEEE802.3i/IEEE802.3u, 10BaseT / 100BaseT
Speed
10M / 100Mbps
Communication Method
Base Band
Switching Method
AUTO MDIX
Maximum Segment Length
100M (Hub between products)
Communication Cable
UTP (Unshielded Twisted Pair)
Modular Jack
RJ45
5.2.2 RJ–45 Pin Layout
Type
Pin No.
Color
Signal
1
Orange/White
TD+
2
Orange
TD-
3
Green/White
RD+
4
Blue
Not Available in 10BaseT
5
Blue/White
Not Available in 10BaseT
6
Green
RD-
7
Brown/White
Not Available in 10BaseT
8
Brown
Not Available in 10BaseT
* When HUB is using, Straight cable should be used.
Ex) Straight Cable Wiring: Connect 1:1 according to the wiring diagram above.
* In case of do not using HUB, do not use HUB, when it is connected directly, Cross Cable should be used.
Ex) Cross Cable Wiring: In the above wiring diagram, TD+ and RD+ are changed, and TD- and RD- are exchanged.

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
11 / 22
5.3 USB Specifications
5.3.1 USB Host
Type
Item
Specification
USB Interface
EHCI/OHCI Specification Version 1.0, USB2.0/1.1 compatible
Communication Method
Control/Bulk
Transfer Speed
480Mb/s
Support Device
USB Storage (FAT16/FAT32 File Format Available)
Connector Type
Type A(1ch)
5.3.2 USB OTG
Type
Item
Specification
USB Interface
USB 2.0
Communication Method
Interrupt/Bulk/Isochronous
Transfer Speed
480Mb/s
Supporting OS
Windows 98SE/2000/XP/VISTA/7/10(32/64bit)
Cable Length
3M(recommended to use M2I's Option Cable), If purchased
separately for less than 1.5 m.
Connect Type
MINI USB AB, Female
Connect Method
Connect through USB OTG
Chapter 6 I/O Interface Specification
6.1 Digital Input
- Digital Sink and Source, Input 16ch: DI0 ~ DIF

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
12 / 22
6.1.1 Digital Input Contact Terminal
No
Name
Description
No
Name
Description
1
DI0
No.0 Channel Contact Input
11
DIA
A Channel Contact Input
2
DI1
No.1 Channel Contact Input
12
DIB
B Channel Contact Input
3
DI2
No.2 Channel Contact Input
13
DIC
C Channel Contact Input
4
DI3
No.3 Channel Contact Input
14
DID
D Channel Contact Input
5
DI4
No.4 Channel Contact Input
15
DIE
E Channel Contact Input
6
DI5
No.5 Channel Contact Input
16
DIF
F Channel Contact Input
7
DI6
No.6 Channel Contact Input
17
COM
Common Terminal
*Field Power (24Vdc or 0V) Connection
8
DI7
No.7 Channel Contact Input
18
COM
9
DI8
No.8 Channel Contact Input
19
COM
10
DI9
No.9 Channel Contact Input
20
COM
6.1.2 Digital Input Terminal Specification
6.2 Digital Output
- Digital Sink, Output 16ch: DON0 ~ DONF
Item
Description
Number of Inputs
16 channels Sink and Source Type
Input Voltage Range
24Vdc typ., ON-state: Min. 10.2Vdc~Max. 28.8Vdc, OFF-state: Max. 5Vdc
Input Current in On State
Typ. Input Impedance
Typ. 4.7KΩ
Input Signal Delay
OFF to ON: Max. 0.1ms, ON to OFF: Max. 0.5ms
Input filter(digital)
0.5ms
System Power Dissipation
Max. 70mA
Isolation
I/O to Logic: Photocoupler isolation
Field Power
Typ. 24Vdc (11.0Vdc ~ 28.8Vdc)
Pin No.
Removable Terminal Block 20P

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
13 / 22
6.2.1 Digital Output Contact Terminal
No
Name
Description
No
Name
Description
1
DON0
No. 0 Channel Contact Output
11
DONA
A Channel Contact Output
2
DON1
No. 1 Channel Contact Output
12
DONB
B Channel Contact Output
3
DON2
No. 2 Channel Contact Output
13
DONC
C Channel Contact Output
4
DON3
No. 3 Channel Contact Output
14
DOND
D Channel Contact Output
5
DON4
No. 4 Channel Contact Output
15
DONE
E Channel Contact Output
6
DON5
No. 5 Channel Contact Output
16
DONF
F Channel Contact Output
7
DON6
No. 6 Channel Contact Output
17
F24V
Common Terminal
*Field Power (24VdcV) Connection
8
DON7
No. 7 Channel Contact Output
18
F24V
9
DON8
No. 8 Channel Contact Output
19
F24G
Common Terminal
*Field Power (0V) Connection
10
DON9
No. 9 Channel Contact Output
20
F24G
6.2.2 Digital Input Terminal Specification
Item
Description
Number of Outputs
16 channels Sink Type
Output Voltage Range
24Vdc typ., Min. 11Vdc~Max. 28.8Vdc,
ON-state Voltage Drop: Max. 0.3Vdc@25℃,
OFF-state Leakage Current: Max. 50uA
Output Current in On State
Max. 0.5A /channel @28.8Vdc
Max. On-state Voltage Drop
Max. 0.3Vdc@25℃
OFF-State Leakage Current
Max. 50uA
Output Signal Delay
OFF to ON: Max. 0.3ms, ON to OFF: Max. 0.5ms
System Power Dissipation
Max. 120mA
Isolation
I/O to Logic: Photocoupler isolation
Field Power
Typ. 24Vdc(11.0Vdc ~ 28.8Vdc)
Pin No.
Removable Terminal Block 20P
6.3 Analog Input / Output Specification
- Analog Current, Input 2ch: AIC0, AIC1
- Analog Voltage, Input 2ch: AIV0, AIV1
- Analog Current, Output 2ch: AOC0, AOC1
- Analog Voltage, Output 2ch: AOV0, AOV1

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
14 / 22
AIC
AIV
AOC
AOV
6.3.1 Analog Input / Output Contact Terminal
No.
Name
Description
1
AIC0
0 Channel Contact Analog Current Input
2
AIC1
1 Channel Contact Analog Current Input
3
AIV0
0 Channel Contact Analog Voltage Input
4
AIV1
1 Channel Contact Analog Voltage Input
5
AOC0
0 Channel Contact Analog Current Output
6
AOC1
1 Channel Contact Analog Current Output
7
AOV0
0 Channel Contact Analog Voltage Output
8
AOV1
1 Channel Contact Analog Voltage Output
9
AGND
Analog Ground
10
AGND
Analog Ground
6.3.2 Analog Input / Output Terminal Specification
Item
AIC0, AIC1
AIV0, AIV1
AOC0, AOC1
AOV0, AOV1
Number of Inputs
2 channels, Input
Analog current Type
2 channels, Input
Analog voltage Type
2 channels, Output
Analog current Type
2 channels, Output
Analog voltage Type
Typ. Input Impedance
Max.250Ω
Min.500KΩ
N/A
N/A
Load
N/A
N/A
Max.350Ω
Min.5KΩ
Sensor Type and Input
Range / Output Range
Input, 0~20mA
Input, 0~5 Vdc
Output, 0~20mA
Output, 0~5 Vdc
DATA Format
16bits Integer
Resolution
16bits, 0.3uA/Bit
16bits, 0.076mV/1bit
16bits, 0.3uA/Bit
16bits, 0.076mV/1bit
Conversion Time
4ms / All channel
Module Error
±0.1% Full Scale @25℃, ±0.3% Full Scale @0℃, 60℃
Isolation
Capacitive isolation
Common Type
2 COM (Single Common)
System Power Dissipation
Max. 200mA
Field power
Max. 60mA@24Vdc
Pin No.
Removable Terminal Block 10P (3.5mm pitch)
6.4 RTD Input
- Analog RTD, Input 2ch: RTD0*, RTD1*

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
15 / 22
6.4.1 RTD Input Contact Terminal
No.
Name
Description
1
RTD0A
PT100 No.0 Channel A Terminal Input (WHITE)
2
RTD0B
PT100 No.0 Channel B Terminal Input (RED)
3
RTD0B’
PT100 No.0 Channel B’ Terminal Input (RED)
4
RTD1A
PT100 No.1 Channel A Terminal Input (WHITE)
5
RTD1B
PT100 No.1 Channel B Terminal Input (RED)
6
RTD1B’
PT100 No.1 Channel B’ Terminal Input (RED)
7
AGND
Analog Ground
8
AGND
Analog Ground
9
AGND
Analog Ground
10
AGND
Analog Ground
6.4.2 RTD Input Terminal Specification
Item
Description
Number of Inputs
2 channels analog RTD Type
Sensor Type and Input Range
PT100 / -200.0 to +850.0°C
DATA Format
16bits Integer
Resolution
0.0312ºC/1bit
Conversion Time
Approx.70ms, All channel @50hz
Module Error
±0.1% Full Scale @25℃, ±0.3% Full Scale @0℃, 60℃
Isolation
Capacitive isolation
Common Type
2 COM (1 common / 1 channel)
System Power Dissipation
Max. 70mA
Field power
N/A
Pin No.
Removable Terminal Block 10P (3.5mm pitch)
* 3-wire Only.
** Compatible only for “PT100”, “PT1000”is not available.
*** A lead wire’s color is defined by IEC 60751-2008 Standard (*Request for Industrial Platinum Temperature
Sensor), and all of wire colors are shown as below.
Unavailable Available Unavailable

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
16 / 22
6.4.3 Rated Input Range (℃) and Data (DEC) Range

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
17 / 22
Chapter 7 Installation
7.1 Installation Requirements
(1) For the performance, ventilation and safe use of the equipment, keep the distance between the back of the
main unit and each wall of the container at least 100mm and install the cooling fan when installed in an
enclosed space.
(2) It should be installed within -10 ~ 50°C and 10~80% relative-humidity, otherwise the screen may be
changed or cause malfunction and damage.
(3) Be sure that heat from surrounding equipment does not cause product to exceed its standard operating
temperature.
(4) When you don’t see within 30°, you may not see clearly When installing the product in a slanted position,
The product screen should not incline more than 30°.
(5) In order to minimize external mechanical hazards, please control the mechanical hazards of the surrounding
environment.
7.2 Installation Procedure
In order to install this product, please follow the following procedure.
(1) Panel Cut-out
Make a panel cut which product is mounted and insert the product to the panel form the front side.
(2) The Size of Panel Cut
Making the Panel Cut (Mounting Size) per each TOPRW Series as below Table, Before Installation.
IP65
IP2X
-10 ~ 50°C, 10~80%
-10 ~ 50°C, 10~80%

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
18 / 22
Model
A (mm)
B (mm)
C (mm)
TOPRW0700WD-IO
197(+1.0/0)
127(+1.0/0)
1.6~5.0(+1.0/0)
(3) Clamp Fixing
Install clamps with this product should be installed as follows to maintain the IP performance of the device.
a. Insert the clamp into the slot of the product.
b. Screw the unit into the panel cut with a screwdriver.

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
19 / 22
If the screw is over tightened, it may cause the front deformation, thus resulting the touch sensor
can’t work properly Tighten the screws to a torque of 0.2N.m.
Caution: If the torque of screwing is not 0.4N.m, IP specification will not be secured.
(4) I/O Terminal Cable Finishing
After wiring the I/O cables to the product, tighten the cables with a fixing hole on product side and cable tie.
Chapter 8 Wiring
8.1 Power Wiring
Caution: With a power and ground cables’ wiring, using Pin Terminal is important for maintaining product’s
performance. Without using specified Pin Terminals as below, it can cause electric shocks from abnormal cable
connection. Users and managers should must be well-informed of following instructions.
(1) The Power cable should have the following specification.
Power Cable Specification
0.75~2.5mm2(18~12AWG)
F.G Cable Specification
Over 4mm2(11AWG)
Conductor Type
Simple or Standard Wire
Bolt tightening force
≥0.4 N.m
Conductor Length
Temperature rating of the
field installed conductors
65℃or under

Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
20 / 22
(2) I/O Terminal Block’s wiring of Pin Terminal
B
F
D
AWG Spec.
Available Range
1.1 ~ 1.5mm
8 ~ 10mm
3mm or less
26 ~ 20
Recommended Spec.
1.5mm
10 mm
20
(3) Wiring of power is as follows.
8.2 Ground Wiring
1) The product has enough anti-noise measure, so except that there are many noises.
Specially, the ground is not needed. When doing ground, please refer to the followings.
2) The ground should be the exclusive ground. The ground should be type Class 3 ground. (Ground resistor is
less than 100Ω.)
3) When you cannot do the exclusive ground, do common ground like figure B).
(4) Use the cable more than 4mm2. Put the point of the ground near product and shorten ground line.
A) Exclusive ground
B) Common ground
C) Common ground
Table of contents