Precision Air V6 User manual

Precision Air V6 Inflator
Instruction Sheet
Size Setting Chart
1 Precision Air Inflator
1 Power Cord
1 Foot Pedal
1 Carrying Case
2 Latex Outlets
2 Extension Tips
1 Double Bubble Outlet
Precision Air Inflator Includes:
READ PRIOR TO USE:
1. This appliance is not to be used by persons (including children) with reduced physical, sensory or mental
capabilities or lack of experience, unless supervised or instructed.
2. To prevent the risk of electrical shock, do not use the Precision Air Inflator outdoors when weather conditions
are wet. Never operate unit on a wet floor or work area.
3. Prior to plugging the Precision Air Inflator into an electrical outlet, verify that the electrical rating (listed on the
label on the back of the Precision Air Inflator) is suitable for the outlet. The Precision Air is not recommended for
use in countries where electrical current is not consistently regulated.
4. Operate the Precision Air in a temperature controlled environment. When working outdoors, keep the unit
out of direct sunlight. Avoid operating unit outdoors in extremely hot weather. If the unit reaches temperatures
that exceed normal working conditions, the thermal shut-off control will automatically shut the system down.
5. If the Precision Air Inflator malfunctions or is damaged in any way discontinue use and unplug unit from
electrical outlet. Contact an authorized Conwin Service Center for details on how to receive service.
Never attempt to repair the Precision Air Inflator yourself. Opening the Precision Air Inflator case will automatically
void manufacturer warranty. Contact an authorized Conwin Service Center for all repairs.
Extension Tip
Foot Pedal
Digital Settings
Latex Outlet
To attach the outlets, firmly press
on to each filling port.
Plug the foot pedal into
the side of the unit.
Plug the power cord into the side
of the unit and into an electrical
outlet. (A power strip with a surge
protector is recommended.) The
digital display will appear when
unit has power.
Reference the Size Setting Chart below to set
the Precision Air for the proper balloon size. Set
the appropriate number of Seconds by pressing
the arrow buttons on the left side of the control
panel digital display window.
Set the appropriate number of Tenths of a
Second by pressing the arrow buttons on
the right side of the control panel digital
display window.
The following settings should be used as guidelines
for the Precision Air. Please note that size settings
will vary based on user preference, balloon color,
manufacturer and from unit to unit. To adjust the
size of balloon to your individual preference it is
necessary to inflate test balloons.
BALLOON SIZE APPROX. TIME SETTING
5" BALLOON 0.8 SECONDS
9" BALLOON 1.5 SECONDS
11" BALLOON 2.5 SECONDS
16" BALLOON 8 SECONDS
11
22
3
Setting the Precision Air Inflator
Getting Started
Inflating Balloons with the Precision Air Inflator
Place the Extension Tip over the Latex Outlet
when inflating 5" balloons. Slide the neck of
the balloon all the way down on the Extension
Tip until the neck is touching the base.
For 9" balloons and larger, remove the
Extension Tip and roll the neck of the balloon
over the Latex Outlet.
Tap the foot pedal to begin the inflation cycle. When the
system automatically shuts-off, remove the balloons from the
outlets without allowing any of the air to escape, and tie. For
continuous run cycle tap foot pedal 3 times. To deactivate tap
foot pedal once.
12
3
Using & Resetting
the Counter
• Every time the foot pedal is pressed the cycle
count will be displayed on the digital display
windows.
• The time setting for the inflation cycle will
disappear once the foot pedal has been
pressed. To verify or change the time setting
for the inflation cycle, press any of the arrow
buttons on the control panel once.
• The balloon time setting will be displayed
on the digital window. Press the Reset button
in the center of the control panel to set the
counter back to zero.
• Readjust the built-in cycle counter by
increasing or decreasing the number should
a balloon pop while inflating.
To achieve consistent results, do not cover the opening of the Extension Tips with your fingers.

Service & Warranty
For assistance with service & repair issues or for warranty information,
please visit ConwinOnline.com, or call (818)-246-9233
CONWIN
4510 Sperry Street • Los Angeles, CA 90039
Phone (818) 246-9233 FAX (818) 246-6862
092016 © Conwin Inc.
If you detect balloons are not being identically sized from both outlets, follow the instructions below to recalibrate your inflator.
NOTE: Always use 11" balloons when comparing sizes. Once the desired size is reached, all balloon sizes
should consistently inflate to the same size when the digital settings are changed. For time settings, refer to
the Size Setting Chart on the front of this instruction sheet.
Determine which outlet is not inflating
to the correct size and remove the
detachable friction fit outlet from the
filling port by pulling upward and gently
twisting as needed.
To increase the size of the balloon, turn
the tool counter clockwise in quarter
turn increments. To decrease the size
of the balloon, turn the tool clockwise in
quarter turn increments. IMPORTANT:
Be careful not to over tighten the setting.
STOP turning the tool clockwise if you feel
resistance on the tool.
Remove the allen wrench and press the
detachable friction fit outlet back onto
the filling port by pushing downward
and gently twisting as needed. Inflate
two balloons to compare sizes. Repeat
steps 1 through 3 until both balloons are
identically sized.
Insert the allen wrench into the filling outlet. Gently apply
downward pressure and slowly rotate the tool until you hear a
“click” sound and feel the tool become fully engaged in the outlet.
Calibration Instructions
1 2 3 4
A 3/8 (9mm) allen wrench is required for calibrating the Precision Air.
Setting
Inflation Mode
Double Bubble Inflation Instructions
Press-fit the Double Bubble Outlet
onto the inflating outlets of the
Precision Air. Attach the yellow hose
to the right outlet and the blue hose
to the left outlet.
Set the Precision Air to MODE 2
on the control panel. Reference the
following chart to set the unit to
properly inflate the balloons.
Place the 11" balloon over the blue
hose.
Place the 16" balloon over the
11" balloon and the yellow hose.
Hold firmly to prevent helium
from escaping during the inflation
process.
Tap the foot pedal to inflate the
balloons. After the balloons are
fully inflated, pinch the neck of the
balloons together and remove the
Double Bubble outlet quickly to
prevent helium from escaping.
2
14 5
Stretch the neck of the inside 11” balloon
around the neck of the outside 16” balloon.
Tie off the balloon.Pull the neck of the inside 11” balloon while
pinching the necks of the 2 balloons together.
Tying Double Bubble Balloons
23
To increase
balloon size
To decrease
balloon size