USER
MANUAL
EASY$AIR
15
Models:
PMI15F
shown
PM15P
Reo
SAVE
THESE
INSTRUCTIONS
ACAUTION
Federal
(USA)
law
restricts
this
device
to
sale
by
or
on the
order
of
a
physician.
PRECISION@
MEDICAL.
300
Held
Drive
Tel:
610-262-6090
Northampton,
PA
18067
:
Fax:
610-262-6080
CONTENTS
SAFETY
SYMBOL
DEFINITIONS.
RECEIVING
INSPECTION.
SPECIFICATIONS.
INTENDED
USE
GROUNDING
INSTRUCTIONS..
WARNINGS...
00000
COMPONENT
IDENTIFICATION
OPERATING
INSTRUCTIONS...
CLEANING
/
MAINTENANCE
.....
REPLACEMENT
PARTS
LIST...
RETURNS
TROUBLESHOOTING
a
WARRANTY
rare
10
DANGER
indicates
an
imminently
hazardous
situation
which,
if
not
avoided,
will
result
in
death
or
serious
injury.
ADANGER
WARNING
indicates
a
potentially
hazardous
situation
AWARNING
which,
if
not
avoided,
could
result
in
death
or
serious
injury.
:
CAUTION
indicates
a
potentially
hazardous
situation
ACAUTION
which,
if
not
avoided,
may
result
in
minor
or
moderate
injury.
CAUTION
used
without
the
safety
alert
symbol
indicates
a
potentially
hazardous
situation
which,
if
not
avoided,
may
result
in
property
damage.
CAUTION
Attention,
Consult
ACCOMPANYING
DOCUMENTS
Type
B
Equipment
Protective
Earth
Ground
Power
On
o-o»>
|
IR
Power
Off
1
RECEIVING
INSPECTION
Remove
product
from
package
and
inspect
for
damage.
If
there
is
any
damage,
do
not
use.
Contact
your
Equipment
Provider.
INTENDED
USE
To
supply
breathable,
compressed
air
for
respiratory
care
devices
having
performance
requirements
within
the
stated
performance
of
the
PM15F
or
PM15P
(see
Specifications).
SPECIFICATIONS
Operating
Range:
PM15P
Output:
PM15F
Output:
(+
1
LPM)
(Models
Equiped
with
a
Pressure
Gage)
(Models
Equiped
with
a
Flow
Gage)
50
psi..
„minimum
15
LPM
LPM
-
as
set
and
read
on
the
gauge
Maximum
Rated
Sustained
Pressure:
60
psi
Dimensions:
Length:
16”
(40.6
cm)
Width:
74”
(18.4
cm)
Height:
10%"
(26.0
cm)
Weight:
20.4
Ibs
(9.3
kg)
Shipping
Weight:
241bs
(10.9
kg)
Electrical:
PM15F
&
PM15P:
108
-
132
VAC,
60
Hz,
5
Amps
Operating
Temperature
Range:
50°F
to
104°F
(10°C
to
40°C)
Storage
Temperature
Range:
-4°F
to
104°F
(-20°C
to
40°C)
Storage/Operating
Humidity:
Maximum
95%
Non-condensing
Outlet:
Grounded
9/16
-
18
Male
Threaded
Fitting
Safety
Systems:
High
Temperature
Motor
Shutdown
Thermal
Protector:
Class
B,
Thermal
Limit
Automatic
Reset
Equipment
Classification:
Class
|
-
with
respect
to
protection
from
electrical
shock
Type
B
-
degree
of
protection
against
electrical
shock
iPxo
-
degree
of
protection
against ingress
of
liquids
Mode
of
Operation
-
continuous
This
device
meets
the
EMC
requirements
of
EN
55001
1:1998
Group
1
Class
B.
This
device
meets
the
requirements
of
GGA
V-5:2005
section
5.4.
This
product
is
not
suitable
for
use
in
the
presence
of
a
flammable
anesthetic
mixture
with
air,
with
oxygen
or
with
nitrous
oxide.
es
FASVPAIR
15
2
GROUNDING
INSTRUCTIONS
The
product
should
be
grounded.
In
the
event
of
an
electrical
short
circuit,
grounding
reduces
the
risk
of
electrical
shock
by
providing
an
escape
wire
for
the
electrical
current.
This
product
is
equipped
with
a
cord
having
a
grounding
wire
with
a
grounding
plug.
The
plug
must
be
plugged
into
an
outlet
that
is.
properly
installed
and
grounded.
ADANGER
Improper
use
of
the
grounding
plug
can
result
in
a
risk
of
electrical
shock.
AWARNING
Ground
reliability
can
only
be
achieved.
when
the
power
cord
is
connected
to
an
equivalent
receptacie
marked
“Hospital
Grade".
¡IMPORTANT
SAFEGUARDS
When
using
electrical
products,
especially
when
children
are
present,
basic
safety
precautions
should
always
be
followed, including
the
following:
READ
ALL
INSTRUCTIONS
BEFORE
USING
Read
and
understand
this
manual
before
using
the
product.
This
manual
is
provided
for
your
safety
and
to
prevent
damage
to
the
product.
If
there
is
anything
you do
not
understand,
do
not
use
the
product;
contact
your
Equipment
Provider.
ADANGER
TO
REDUCE
THE
RISK
OF
ELECTROCUTION
*
Always
unplug
product
immediately
after
using.
*
DO
NOT
use
while
bathing.
+
DO
NOT
place
or
store
product
where
it
can
fall
or
be
pulled
into
a
tub
or
sink.
*
DO
NOT
place
or
drop
into
water
or
other
liquid.
¢
DO
NOT
reach
for
a
product
that
has
fallen
into
water.
Unplug
immediately.
EASYfAIR
15
ADANGER
*
DO
NOT
attempt
to
repair
product:
Any
attempt
could
result
in
electrical
shock.
*
Never
use
near
any type
of
flame
or
fiammable/explosive
substances.
*
Caution
must
be
exercised
when
using
this
product
where
oxygen
is
being
administered.
*
Never
allow
product
to
exceed
Operating
or
Storage
Temperature
specifications.
.
AWARNING
TO.
REDUCE
RISK
OF:
BURNS,
ELECTROCUTION,
FIRE;
OR
INJURY
TO
PERSONS:
*
The
product
should
never
be
left
unattended
when
product
is
running:
+
Close
supervision
is
necessary
when
this
product
is
used
by,
ón;
ornear
children
or
invalids.
*
Use
this
product
only
for
its
“Intended
Use"
as
described
‘in
this
manual:
*
DO
NOT
use
attachments
not
recommended
‘by
the
manufacturer.
*
DO
NOT
use.
product
with:
any.
equipment
that
requires
“dry”:
air,
including
ventilators,:gas
blenders; or-flow:generators,
without
a
device
to
properly
dehumidify
the
discharged
air
of
the.
PM15.
*
Never
operate
this
product:
-
¡fit
has'a
damaged
cord
or.
plug
=ifitis
not
working
properly
“fit
has-been
dropped
or
damaged
-
-¡fithas
been:
dropped
into.
water.
Return
the
:product-to
your:
Equipment
Provider
for.
examination
and
repair:
*
Keep
the
cord
away
from
heated
surfaces:
*
Never
use
while
sleepy
or
drowsy.
*
Adjust
to
desired
setting
prior
to
use:
*
Never
drop
or
irisert-any,
object
into
any
opening
or-hole.
00
NOT
cover
air
vents:
Restriction
of
air
flow
willicause
unit
to
overheat,
causing
the
thermal:
reset
to
shut
down
the
product:
*-Connect
this
.product:to
a
properly
grounded:
outlet
only.
See
Grounding
Instructions.
4
COMPONENT
IDENTIFICATION
Carry
Handle
On/Off
(1/0)
Switch
Air
Outlet
Regulator
Knob
Air
Inlet
Filters
Keeper
Fuse
Drawer
AC
Inlet
Hour
Meter
EASYÉAIR
15
=
Power
Cord
OPERATING
INSTRUCTIONS
Prior
to
each
use.
Inspect
product
for
damage.
DO
NOT
use
if
any
damage
is
found.
10.
11.
NOTE:
If
for
any
device
labels
are
missing
or
illegible
contact
your
Equipment
Provider.
Become
familiar
with
the
product
(see
Component
Identification).
Position
product
near
a
properly
grounded
electrical
receptacle.
Allow
a
minimum
of 4"
(10
cm)
clearance
on
ail
sides
to
ensure
adequate
air
flow
for
cooling
of
product.
Be
sure
the
On/Off
(1/0)
Switch
is
in
the
Off
(O)
position.
Be
sure
the
Power
Cord
is
properly
connected.
Attach
appropriate
device
to
the
Outlet
Fitting,
securely,
without
overtightening.
Pull
Regulator
Knob
OUT
to
unlock
reguiator,
ihen
turn
Knob
fully
counterclockwise.
Press
the
On/Off
(I/O)
Switch
to
the
On
(I)
position.
Adjust
pressure/flow,
To
INCREASE
pressure/flow
-
Turn
Knob
CLOCKWISE
To
DECREASE
pressure/flow
-
Turn
Knob
COUNTERCLOCKWISE
Push
Regulator
Knob
IN
to
lock
pressure/flow
setting.
Compressor
is
now
ready
to
use.
When
the
compressor
is
not
in
use,
press
the
On/Off
(I/O)
Switch
to
the
OFF
(O)
position.
BEFORE
STARTING
UNIT
Pull
out
regulator
Knob
to
unlock,
then
turn
Knob
fully
counterclockwise.
—€—__t1pR%j2]2pq«©«©=ÙotASYAIR
15
6
CLEANING/MAINTENANCE
AWARNING
Disconnect
product
from
any
external
power
source
before
cleaning.
WEEKLY:
1.
Check
both
Air
Filters
on top
rear
of
cabinet
for
dust
buildup.
2.
if
dust
buildup
occurs,
unplug
product,
remove
Air
Filters
from
their
recessed
areas and
wash
in
warm,
soapy
water
and
rinse.
3.
Absorb
excess
water
from
filters
with
a
dry
towel.
4.
Return
filters
to
their
original
locations.
CAUTION
*
Excessive
dust
buildup
on
external
filters
will:
reduce
performance
of
product.
Ifthis
occurs,
cleanor
replace
with
new
filters.
+
The
Air
Filter
on
top
of
the
compressor
does:
not
filter
out saline:
Treatments
using
nebulized:saline
will-draw
the
saline
mist
back
into:the
product:
Saline
causes
rapid:
deterioration
of
the
compressor:seals
and
will
void
the
warranty.
AS
NEEDED:
Clean
exterior
surfaces
with
a
cloth
or
sponge
dampened
with
soap
and
water.
Wipe
dry with
a
clean
cloth
or
paper
towel.
AWARNING
*
DO
NOT
immerse
product
in
liquid.
“If
product
is
used
for
treatment
of
infectious:
disease;
consult
your
physician
or
healthcare
professional
for
recommended
cleaning
procedures:
AT
8500
HAS:
Return
product
to
Equipment
Provider
for
compressor
maintenance
(including
rebuilding
pump).
Call
Precision
Medical,
Inc.
for
Preveritative
Maintenance
Services.
REPLACEMENT
PARTS
LIST
503237
Filter,
Large
502391
Filter,
Small
502597
User
Manual
RETURNS
Refer
to
Precision
Medical,
Inc.'s
Return
Policy,
at
www.
precisionmedical.com
or
contact
Precision
Medical,
Inc..
Note:
When
returning
this
product,
disconnect
the
power
cord
from
the
back
of
the
unit.
MAINTENANCE
RECORD
Unit
Serial
No:
In
Service
Date:
Date
Hours
Maintenance
Performed
TROUBLESHOOTING
If
the
Easy
Air
15
Compressor
fails
to
function,
consult
the
Troubleshooting
guide
below.
AWARNING
NOT
open
cabinet:
There
are
no
user
serviceable
parts
inside.
To
avoid
injury,
DO
If
the
problem
cannot
be
corrected,
consult
your
Equipment
Provider
or
Precision
Medical,
Inc.
Problem
Probable
Cause
Remedy
A.
Product
does
not
operate
1
2.
3.
~
.
On/Off
Switch
in
Off
position
Power
Cord
not
connected
properly
Product
overheated
.
Blown
Fuse
.
Power
Interruption
1.
Push
On/Off
Switch
to
On
position
2.
Check
Power
Cord
connections
3.
Shut
product
Off
Wait
15
minutes
Ensure
vents
are
clear
4.
Repiace
Fuse
5.
Turn
off
product.
When
Power
restored,
repeat
Start
Up
Procedure.
B.
Unable
to
adjust
pressure/fiow
.
Locked
Regulator
Knob
1.Puil
Regulator
Knob
out
C.
Overheating
.
Poor
Ventilation
1.
Move
product
to
a
cooler,
better
ventilated
area
2.
Dirty
Air
Filters
2.
Clean
Air
Filters
D.
Low
pressure/flow
|
1.
Loose
connection
at
|
1.
Tighten
connection
outlet
fitting
2.
Improper
regulator
|
2.
Re-adjust
regulator
adjustment
LIMITED
WARRANTY
AND
LIMITATION
OF
LIABILITY
Precision
Medical,
Inc.
warrants
that
EASY
AIR
15
Compressor
(the
Product}
will
be
free
of
defects
in
workmanship
and/or
material
for
One
(1)
year
from
shipment
Should
any
failure
to
conform
to
this
warranty
appear
within
the
applicable
period,
Precision
Medical,
Inc.
shall,
upon
written
not
cation
thereof
and
substantiation
that
the
goods
have
been
stored,
installed,
maintained
and
operated
in
accordance
with
Precision
Medical,
Inc.'s
instructions
and
standard
industry
practice,
and
that
no
modifications,
substitutions,
or
alterations
have
been
made
to
the
goods,
correct
such
defect
by
suitable
repair
or
replacement
a’
its
own
expense.
ORAL
STATEMENTS
DO
NOT
CONSTITUTE
WARRANTIES.
The
representatives
of
Precision
Medical,
Inc.
or
any
retailers
are
no!
authorized
to
make
oral
warranties
about
the
merchandise
described
in
this
contract,
and any
such
statements
shall
not
be
relied
upon
and
are
not
part
of
the
contract
for
sale.
Thus,
this
writing
is
a
final
complete
and
exclusive
statement
of
the
terms
of
that
contract.
THIS
WARRANTY
IS
EXCLUSIVE
ANDIS
IN
LIEU
OF
ANY
WARRANTY
OF
MERCHANTABILITY,
FITNESS FOR
A
PARTICULAR
PURPOSE
OR
OTHER
WARRANTY
OF
QUALITY,
WHETHER
EXPRESS
OR
IMPLIED.
Precision
Medical,
inc.
shall
not
under
any
circumstances
be
liablefo
special,
incidental
or
consequential
damages including
but
natlimited
to
lost
profits,
lost
sales,
or
injury
to
person
or
praperty.
Correction
of
non-conformities
as
provided
above
shall
constitute
fulfillment
o
all
liabilities
of
Precision
Medical,
Inc.
whether based
on
contract,
negligence,
strict tort or
otherwise.
Precision
Medical,
Inc.
reserve:
the
rightto
discontinue
manufacture
of
any
product
or
change
product
materials,
designs,
or
specifications
without
notice.
Precision
Medical,
Inc.
reserves
the
right
to
correct
clerical
or
typographical
errors
without
penalty.
Contact
your
Equipment
Provider
for
replacement
parts
and
accessories.
Your
Equipment
Provider
is:
PRECISIONÊ
MEDI
。
Precision
Medical,
Inc.
300
Held
Drive
Northampton,
PA
18067
USA
Toil
Free
Tet:
800-272-7285
Toll
Free
Fax:
800-352-1240
Tel:
610-262-6090
Fax:
610-262-6080
Visit
us
on
the
Web:
www.precisionmedical.com
502597
Rev
7
(10/06)
(M?)
PRINTED
IN
USA
PRECISION
MEDICAL
EASY
AIR
15
COMMONLY
USED
REPLACEMENT
PARTS
-DESCRIPTI
Gauge
502392
5342330
Regulator
502892
5344085
PM
Kit
504593
1070526
Muffler
Assy
503241
1067754
A/C
Inlet
503803
5345749
Tee
502395
5349485
Nut
Panel
502276
5342009
Screw,
mounting
504085
1062012
Washer
503339 1091339
Filter,
small
50239110
1156121
Filter,
large
50323710
1155535
Barb
1790
5342342
Motor
Rebuild
Kit
(square)
1156
5342083
Motor
Rebuild
Kit
(round)
502060
1155263
Screw,
case
107010
1064174

This manual suits for next models

2

Other Precision Medical Air Compressor manuals

Precision Medical PM15F User manual

Precision Medical

Precision Medical PM15F User manual

Precision Medical PM15F User manual

Precision Medical

Precision Medical PM15F User manual

Precision Medical EasyComp PM50-3HG User manual

Precision Medical

Precision Medical EasyComp PM50-3HG User manual

Precision Medical PM50 User manual

Precision Medical

Precision Medical PM50 User manual

Popular Air Compressor manuals by other brands

Metabo Mega 370/100 W Original operating instructions

Metabo

Metabo Mega 370/100 W Original operating instructions

FScurtis CA series Installation and operating instruction manual

FScurtis

FScurtis CA series Installation and operating instruction manual

Clarke SHHH AIR 100/24 Operation & maintenance instructions

Clarke

Clarke SHHH AIR 100/24 Operation & maintenance instructions

Scheppach HC51 Original instruction manual

Scheppach

Scheppach HC51 Original instruction manual

Scheppach HC60 Original instruction manual

Scheppach

Scheppach HC60 Original instruction manual

Ronix RH-4264 quick start guide

Ronix

Ronix RH-4264 quick start guide

California Air Tools 8012SPC owner's manual

California Air Tools

California Air Tools 8012SPC owner's manual

Stratus SRC25 Installation and service manual

Stratus

Stratus SRC25 Installation and service manual

Ries Hitachi Highly WHP09400PSV-C9EU installation manual

Ries

Ries Hitachi Highly WHP09400PSV-C9EU installation manual

DeVilbiss Air Compressor Operator's manual

DeVilbiss

DeVilbiss Air Compressor Operator's manual

Danfoss CH290 Application guidelines

Danfoss

Danfoss CH290 Application guidelines

Milwaukee 2475-20 Operator's manual

Milwaukee

Milwaukee 2475-20 Operator's manual

GEA Bock HGX2/70-4 CO2 T Assembly instructions

GEA

GEA Bock HGX2/70-4 CO2 T Assembly instructions

FScurtis ECO Series Operator's manual

FScurtis

FScurtis ECO Series Operator's manual

Meec 200-013 operating instructions

Meec

Meec 200-013 operating instructions

Kingsley Bushranger RV AIR owner's manual

Kingsley

Kingsley Bushranger RV AIR owner's manual

Craftsman 919.152142 owner's manual

Craftsman

Craftsman 919.152142 owner's manual

Truper COMP-50S manual

Truper

Truper COMP-50S manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.