20
lead to the pump failure and to the subsequent spillage of that are harmful to persons and to the
environment.
For installation and use in a potentially explosive environment, comply with these general precau-
tions:
• Ascertain that the pump is full and if possible, that the uid level is above 0.5 m.
• Ascertain that the conveyed uid does not contain or cannot contain large solids or solids of a
dangerous shape.
• Ensure that the intake or delivery ports are not obstructed nor limited to avoid cavitation or
pneumatic motor strain.
• Also ascertain that the connection piping is strong enough and cannot be deformed by the pump
weight or by the intake. Also check that the pump is not burdened by the weight of the piping.
• If the pump is not used for a long period of time, clean it carefully by running a non-ammable liquid
detergent through it which is compatible with the pump’s construction materials.
• If the pump was turned o for a long period of time, circulate clean water in it for a couple of
minutes to avoid incrustations
• Before operation, after long periods of disuse, clean the internal and external surfaces with a damp
cloth, check the grounding ATEX ZONE.
• Always protect the pump against possible collisions caused by moving objects or by various blunt
materials that may damage it or react with its materials.
• Protect the pump’s surroundings ambient from splashes caused by accidental pump failure.
WARNING:
• The air supply pressure must never be over 7 bar or below 2 bar.
• When using the pump with aggressive or toxic liquids or with liquids that may represent a health ha-
zard you must install suitable protection on the pump to contain, collect and signal any spills: DANGER
OF POLLUTION, CONTAMINATIONS, INJURIES AND/OR DEATH.
• The pump must not be used with uids that are not compatible with its construction materials or in
a place containing incompatible uids.
CAUTION: It is prohibited to install the pumps without on-o valves on the intake and delivery sides
which intercept uids in case of spillage.
CAUTION: It is prohibited to install the pumps without on-o, three-way or check valves on the air
supply piping to prevent the pumped liquid from entering the pneumatic circuit if the diaphragms
are broken: danger of uid entering the compressed air circuit and being discharged into the environ-
ment.
WARNING:
• In situations where the user foresees the possibility of exceeding the temperature limits indicated
in this manual, it is necessary to install a protection device on the equipment that prevents to achieve
the maximum operating temperature allowed. If exceeded, respect to the maximum marking tempe-
rature is not guaranteed.
• The pumps must always be grounded irrespective of any organ to which it is connected. Lack of
grounding or incorrect grounding will cancel the requirements for safety and protection against the
risk of explosion.
•It is prohibited to use pumps made with non-conductive material, which can be statically char-
ged and that are not properly grounded for ammable liquids: RISK OF EXPLOSIONS DUE TO STATIC
CHARGE.
CAUTION: Aggressive, toxic or dangerous liquids may cause serious injuries or hazard to health, there-
fore it is prohibited to return a pump containing such products to the manufacturer or to a service