Prestel CP-RS8 User manual

USER MANUAL
Prestel CP-RS8
Integrated Control System

Thank you for purchasing this product
For optimum performance and safety, please read these instructions carefully
before connecting, operating or adjusting this product. Please keep this manual
for future reference.
Surge protection device recommended
This product contains sensitive electrical components that may be damaged
by electrical spikes, surges, electric shock, lighting strikes, etc. Use of surge
protection systems is highly recommended in order to protect and extend the
life of your equipment.
Table of Contents
1. Introduction...........................................................................................
2. Features.................................................................................................
3. Package Contents................................................................................
4. Specifications.......................................................................................
5. Operation Controls and Functions......................................................
5.1 Front Panel.......................................................................................
5.2 Rear Panel.......................................................................................
6. Application Example............................................................................
1
1
2
2
4
4
5
8

1. Introduction
2. Features
-1-
☆With 8 two-way serial ports to connect matrixes, projectors or other
A/V devices
☆With 8 IR outputs/one-way serial ports to connect DVD, TV sets, or
other home appliances
☆With 8 relay ports to control lights, doors or curtains
☆With 8 digital inputs to receive sensor signals
☆Capable of connecting with Ethernet-control devices for Ethernet
monitoring and control
☆IR learning
☆Provide a superb-performance Web server, supporting on-line firmware
upgrade
☆Compliant with standard network communication protocols
☆Password protection against unauthorized accesses
☆Built-in sync clocks
☆Standard 1U rack mounting
☆220V AC power supply
☆Support factory reset
The Integrated Controller is designed to be utilized in the sectors of
commanding center, automated office system, multi-media room and
smart home. With a programmable interactive user interface over
configuration protocols, the integrated system provides intelligent
networking service, ideal for the establishment of modern commanding
and control center. The Controller features 8 two-way serial ports, 8 IR
outputs, 8 Relay ports, 8 digital I/O ports and 1 Gigabit Ethernet port,
suitable for large-scale application systems to control multiply devices.
The Controller is used in a diverse range of installations and applications
across industries including emergency alarming centers, C4ISR solutions,
governmental administration centers, smart buildings, multi-media
conference rooms, multi-functional halls, training centers, showroom,
broadcasting studios, and industrial automation.

3. Package Contents
①1 × Integrated Controller
②4 × 3-pin Phoenix Connectors
③1 × 4-pin Phoenix Connector
④2 × 5-pin Phoenix Connectors
⑤4 × 8-pin Phoenix Connectors
⑥4 × 9-pin Phoenix Connectors
⑦2 × Mounting Ears
⑧6 × Machine Screws
⑨1 × 220V/10A AC Power Cord
⑩1 × User Manual
4. Specifications
8GB EMMC Flash
Technical
RAM 2GB DDR4 RAM
Flash Memory
CPU ARM Cortex-A53 1.8GHz
Operation System Android 9
LEDs
1 × IR Learning LED
1 × Power LED
1 × LAN LED
1 × Status LED
8 × TX LEDs
8 × RX LEDs
8 × IR/Serial LEDs
8 × Relay LEDs
8 × I/O LEDs
-2-

440mm (W) × 200mm (D) × 44mm (H)
-3-
Power Supply
Dimension
Weight 2.1kg
Housing Metal enclosure with aluminium alloy front panel
Color Black
Operation
Temperature 0°C ~ 40°C / 32°F ~ 104°F
Relative
Humidity 10~90% RH (non-condensing)
Power
Consumption
55W (48W for external power supplies connected
via the H-NET port.)
Mechanical
AC110~220V 50/60Hz
Connection
COM1/2/3/4
4
× 9-pin Phoenix Connectors
, for two-way RS-232/422/
485 serial data communication
COM5/6/7/8
4
× 3-pin Phoenix Connectors
, for RS-232 serial data
communication
IR-SERIAL
OUTPUT
2
×
8-pin Phoenix Connectors
, for IR transmitting or one-
way RS-232 serial data communication
RELAY
OUTPUT
2
×
8-pin Phoenix Connectors
, low-voltage relays,
isolated, normally open,
switching up to 30VDC, 2A / 125VAC, 1A
LAN A standard 10M/100M/1000M Ethernet RJ45 interface
USB 1 × USB TYPE A (function reserved)
COMPUTER 1 × USB TYPE B
H-NET
1
× 4-pin Phoenix Connectors
, private bus interface
(function reserved)
RESET
1
× RESET, for restoring factory default
DIGITAL I/O
2
× 5-pin Phoenix Connectors
, for digital signal inputting
IR
1
× IR learning Window
Installation Standard 19-inch cabinet (with mounting ears) or flat
installation

8TX LEDs
(Yellow)
8 LEDs, each of which blinks when the corresponding
TX port is transmitting data; If not, the LED is off.
5. Operation Controls and Functions
-4-
34
1/5
No. Name Function Description
3
4I/O LEDs
(Yellow)
8 LEDs, each of which blinks in yellow to indicate that the
corresponding I/O port has got signal level fluctuation; If not,
the LED is off.
Relay LEDs
(Yellow)
8 LEDs, each of which illuminates in yellow to indicate that
the corresponding relay port is closed; If not, the LED is off.
5.1 Front Panel
5Power LED
(Red) The red LED illuminates when the device is powered on.
6LAN LED
(Green)
The green LED illuminates when the Controller connects
to the network, blinks when it uses network protocols for
data communication.
7STA LED
(Blue)
The blue LED illuminates when the device functions
properly after booting, blinking for factory resetting.
1
IR Learning
Window &
LED (Yellow)
The yellow LED blinks when the IR wave is received;
If not, the LED is off.
2
IR/Serial
LEDs
(Yellow)
8 LEDs, each of which blinks in yellow to indicate that the
corresponding IR/serial port is transmitting data; If not, the
LED is off.
123 4 5 6 7 8 9
9RX LEDs
(Yellow)
8 LEDs, each of which blinks when the corresponding
RX port is receiving data; If not, the LED is off.

-5-
5.2 Rear Panel
No. Name Function Description
1
2
COM1/2/3/4
The controller features 4 sets of programmable two-way
multi-mode serial ports, each of which is a 3.5mm 9-pin
phoenix connector (male), compliant with RS232,
RS232+Hardware Flow, RS485 and RS422 communica-
tion protocols, and capable of configuring 8 baud rates
in the range of 2400-115200bps.
More information on the pin-outs of the connector, see
table 5-1.
COM5/6/7/8
The controller provides 4 sets of programmable single
mode serial port, each of which is a 3.5mm 3-pin phoenix
connector (male), compliant with RS232 communication
protocol, and capable of configuring 8 baud rates in the
range of 2400-115200bps.
The pin-outs of the RS232 ports are PIN1 for TXD,
PIN2 for GND, and PIN3 for RXD.
3 H-NET The reserved private bus interface.
4Ground
Terminal
Used for connecting the ground or the earthing conductor
of the rack.
5100-240V AC
50/60Hz
The power supply port, used for connecting with external
220V/10A AC power.
100-240V AC 50/60Hz
5
1
6
IR-SERIAL OUTPUT
GS GS
6
GS
7
GS
85
RELAY OUTPUT
G4321 G876
COM 4COM 3COM 2COM 1
DIGITAL I/O COMPUTER USB RESET
5
H-NET
RX+
TX+
GND
TXD
RXD
RTS
CTS
RX+
TX+
GND
TXD
RXD
RTS
CTS
RX+
TX+
GND
TXD
RXD
RTS
CTS
RX+
TX+
GND
TXD
RXD
GND
TXD
GND
TXD
GND
TXD
GND
TXD
RXD
RXD
RXD
RXD
RTS
CTS
COM 5 COM 6 COM 7 COM 8
GZY24V
GS
1
GS
2
GS
3
GS
4
GS GS
6
GS
7
GS
85
GS
1
GS
2
GS
3
GS
4
234
7
89
1011
12
6RESET (1)
Reboot: When the device boots up, press and hold the
RESET button for more than 1s less than 5s, then
release it, the STA LED on the front panel will flash for
five times, indicating that the device is going to reboot.
The user projects won’t be auto-uploaded to the
controller after rebooting.

-6-
No. Name
10 Digital I/O
8-CH GPIO dry contact input interface, with a voltage
range of 0~24V, for collecting digital level signals, capable
of low level signal sensing.
7 USB Port The reserved port for function extension.
8 COMPUTER The reserved port for test debugging.
9 LAN
The Controller provides a standard 10M/100M/1000M
Ethernet RJ45 interface with default auto-negotiated speed
for device connection, projects uploading & downloading,
network communication and debugging.
The controller boots up with DHCP enabled by default.
After powering on, when the Controller connects to a network
where there is no router present to assign IP addresses,
the Controller will take the pre-set IP address: 192.168.0.101.
If there is a router present on the same network, the router
will assign an IP address to the Controller in three minutes
and the pre-set IP address will be invalid.
Note: When the controller is DHCP enabled after power on, the router
(if connected to the same network) will assign an IP address to the
Controller. If network is disconnected at this time, the Controller won’t
be able to pre-set an IP address and its IP address would be 0.0.0.0.
If a pre-set IP address is needed, you need to power off the Controller
and then power it on again. If it is in static IP mode after power on, the
Controller won’t preset an IP address either. If there is no router
present, you can connect your PC to the LAN port of the Controller
and modify the PC’s IP address in the range of 192.168.0.X, then the
PC will pre-set an IP address to the Controller in three minutes for data
communication.
Function Description
6RESET (2)
Reset: When the device boots up, press and hold the
RESET button for more than 5s, then release it, the STA
LED on the front panel will flash for 5 times, the device will
reset the user configuration information, the IP will be
restored to DHCP state, the login password of the manage-
ment page will be initialized to “admin”, the device time will
be initialized to automatic acquisition mode, but user
projects won’t be deleted by factory initialization.

-7-
Table 5-1: Pin-outs of the 9-pin phoenix connector for COM1/2/3/4
12 IR-SERIAL
OUTPUT
The Controller features 8 sets of multi-mode 2-PIN
phoenix connectors for IR transmitting or one-way
serial signal outputting. The ports can connect to devices
with signal level 0-5V in RS232 mode. The left pin is for
IR/serial data, the right for GND.
The IR-Serial working mode is programmable:
In IR transmitting mode, the outputting IR wave length
ranges within 20K-60KHZ.
In one-way serial data outputting mode, the left pin is
for TXD, the right for GND, and both are configurable in
the program.
No. Name Function Description
11 Relay OUTPUT
The Controller features 8 sets of relay 2-PIN phoenix
connectors; each relay is isolated and normally open,
and can switch up to 2A 30VDC / 1A 125VAC peak.
The connector does not support voltage output.
PIN1
PIN2
PIN3
PIN4
PIN5
PIN6
PIN7
PIN8
PIN9
RX- (used in RS422 and RS485)
RX+ (used in RS422 and RS485)
TX- (used in RS422 and RS485)
TX+ (used in RS422 and RS485)
GND
TXD (used in RS232 and RS232+hardware flow)
RXD (used in RS232 and RS232+hardware flow)
RTS (used in RS232+hardware flow)
CTS (used in RS232+hardware flow)
Note: In RS485 mode, the wires connecting to PIN1 and PIN3 should be stranded
as one, PIN2 and PIN4 as another one.

6. Application Example
-8-
Network Switch
Touch Screen
Cloud Server
Router
Camera
Cable
I R
Android Pad
Ipad
Laptop
Router
Cable
Cable
Android Pad
Ipad
Laptop
Gateway
CAN COM
GPIO
RELAY
Air Conditioner
Lighting Control
Body Sensor
Audio Processor
COM
Audio
Speaker
DEC Video Controller DEC DEC
PC HDTV HDTV
TV Box
MIC
Cable
Cable Cable
Audio
DEC
Table of contents