Prexiso P2LC15SG User manual

IMPORTANT:
Read before Using EN
1
P2LC15SG
GREEN-BEAM CROSS LINE LASER LEVEL
WITH PLUMB POINTS
www.prexiso-eu.com
WARRANTY
LIMITED
YEARS
2

SAFETY INSTRUCTIONS
Working safely with the measuring tool is possible only when the operating and
safety information are read completely and instructions contained herein are strictly
followed. Never make warning labels on the measuring tool unrecognizable.
SAVE THESE INSTRUCTIONS.
Caution – The use of operating or adjusting equipment or the application or
processing methods other than those mentioned herein, can lead to hazardous
radiation exposure.
2
WARNING!
LASER RADIATION. Do not stare into beam. Class II laser product.
Turn the laser beam on only when using this tool.
Do not remove or deface any product labels.
• Avoid direct eye exposure. The laser beam can cause persons being blinded.
• Do not operate the tool around children or allow children to operate the tool.
• Do not place the tool in a position that may cause anyone to stare at the laser
beam, whether intentionally or unintentionally.
• Do not use on reflecting surfaces such as sheet steel, glass or polished metal etc.
that have shiny, reflective surfaces. The shiny surface could reflect the beam back
at the operator.
• Always turn the laser tool off when not in use. Leaving the tool on increases the risk
of someone inadvertently staring into the laser beam
• Do not attempt to modify the performance of this laser device in any way. This may
result in a dangerous exposure to laser radiation.
• Do not attempt to repair or disassemble the laser-measuring tool. If unqualified
persons attempt to repair this product, serious injury may occur. Any repair required
on this laser product should be performed only by qualified service personnel.
• Use of other accessories that have been designed for use with other laser tools
could result in serious injury.
• Do not operate the tool outdoors.
• Do not place or store tool under extreme temperature conditions.
• Do not operate the tool in explosive environments, such as in the presence of
flammable liquids, gases or dusts. Sparks can be created in the tool which may
ignite the dust or fumes.
Pav. < 1mW λ = 505-525nm tp > 70ps
IEC/EN 60825-1: 2014

TECHINICAL SPECIFICATIONS
3
• Keep the tool away from cardiac pacemakers. The magnet inside the tool
generates a field that can impair the function of cardiac pacemakers.
• Keep the tool away from magnetic data medium and magnetically-sensitive
equipment. The effect of the magnetic can lead to irreversible data loss.
• Measurement may not be accurate if used beyond the rated range of the device.
• The use of optical instruments with this product will increase eye hazard.
• Always make sure any bystanders nearby aware of the dangers of looking directly
into the measuring tool.
• Do not use the laser viewing glasses as safety goggles, they do not protect eyes
against laser radiation.
• Always remove the batteries when cleaning the laser light aperture to laser lens.
*Important: The accuracy is rated within distance of 10 meters. Under unfavorable
conditions, such as in extreme interior illumination, transparent surfaces (eg. glass,
water), porous surfaces (eg. insulation materials) or reflecting surfaces (eg. polished
metal, glass) or very rough surfaces (eg. rough cast, natural stone), the tool’s
measuring range and accuracy will be reduced.
COMPONENT
Leveling Accuracy
Horizontal / Vertical Accuracy
Up Beam Accuracy:
Down Beam Accuracy:
Compensation Range:
Working distance(Line)
Working Distance (Line with Detector):
Working distance(Dot)
Laser Class:
Laser Wavelength
Operating Time (All lasers ON):
Power Source:
IP Rating:
Temperature Range (Operating):
Temperature Range (Storage):
Horizontal Divergence Angle
Vertical Divergence Angle
SPECIFICATIONS
±4mm@10m(±5/32"@32ft) *
±4mm@10m(±5/32"@32ft) *
± 3 mm / 10m ( 1/8”/ 32 ft) *
±4mm@10m(±5/32"@32ft) *
± 4°±1°
25M (82ft)*
50 m (165ft) *
30 m (100 ft) *
Class 2 (IEC /EN60825-1)
505 nm ~ 525 nm
3 hours (Alkaline)
3 x “AA” (LR6)
IP54
-10° C ~ +50° C (14°F~122°F)
-20° C ~ +60° C (-4°F~140°F)
7°
30°

(-)
(+) (-)
(+)(-)
(+)
DESCRIPTION
4
CROSS LINE LASER LEVEL WITH PLUMB POINTS
This self-leveling cross line laser is a highly versatile tool. It can be placed on the
ground, mounted on a door frame or work bench etc.when use the appropriate
accessories eg. magnetic mounting bracket, tripod(not included) etc.
but not limited.
• Self-leveling levels within +4 degrees to -4 degrees with an accuracy of
±4mm@10M (±5/32" @32ft ).
• AA alkaline batteries
A
B
1
6
2
3
4
5
87
6
9C

DESCRIPTION
PRODUCT OVERVIEW
5
Figure A - Laser Tool
1. Keypad
2. Window for Vertical Beam Laser
3. Window for Horizontal Beam Laser
4. Pendulum / Transport Lock
Window for Up Beam Laser
5. Battery Cover
6. 5/8 - 11 Threaded Mount
7. Window for Down Beam Laser
8. 1/4 - 20 Threaded Mount
F1 F2
E
D
F

6
PRODUCT OVERVIEW
Figure B - Laser Tool Battery Location
1. Battery Cover
2. Batteries - 3 x “AA” (LR6) (Included)
Figure C - Pendulum / Transport Lock Positions
Figure D - Keypad Configurations
Figure E - Laser Modes
Figure F - Pulse Mode
KEYPAD, MODES, AND LED
Keypads (See figure D)
Power ON / OFF / Mode Key
Pulse Mode ON / OFF Key
Modes (See figure E)
Available Modes
Horizontal Line
Vertical Line
Horizontal Line and Vertical Line (Cross)
Up and Down Dot Beam
All Line and Dot
LEDs (See figure D)
Power LED - Solid GREEN
Power is ON
Power LED - Blinking RED
Low Battery
Power LED - Solid RED
Replace Battery / Battery Needs Recharging
Pendulum / Transport Lock LED - Blinking RED
Pendulum lock is not locked
Pendulum / Transport Lock LED - Solid RED
Pendulum lock is locked
Pulse LED - Solid GREEN
Pulse Mode is ON
(Can be used with Detector)

UNPACKING
7
When unpacking the box, do not discard any packing materials until
all of the contents are accounted for:
• Self-Leveling Cross Line Laser Tool
• Magnetic mounting bracket
• bag
• 3 x AA alkaline batteries
• Operator’s manual
Carefully lift the compact laser measuring tool out of the package and place it on a
stable, flat surface.
BATTERIES AND POWER
INSERTING/REPLACING THE BATTERY
AA alkaline batteries are recommended for the measuring tool.
To open the battery compartment lid, press the latch and open it. Insert
the batteries provided. Pay attention to the correct
polarity of the batteries according to the
representation on the metal plate inside the lid.
Always replace all batteries at the same time.
Only use batteries from one brand and with
the identical capacity.
NOTE: Remove the batteries from the measuring
tool when not using it for extended periods.
When storing for extended periods, the batteries
can corrode and discharge themselves.
SET UP
Laser Tool
• Place laser tool on a flat, stable surface.
Mounting on Accessories
• Position accessory in a place where it will not be easily disturbed and near the
central location of the area to be measured.
• Set up the accessory as required. Adjust positioning to be sure that the accessory
base is near horizontal (within laser tools compensation range).
• Mount the laser tool to the accessory by using the appropriate fastening method. At
the bottom of the tool, a 1/4"-20 nut is located. Mount the tool to accessories like
magnetic mounting bracket or tripod (not included) by assembling the tool nut with
the 1/4"-20 screw on the accessories. With the accessories, the tool can work
under various applications which makes jobs done easier.

OPERATION
8
CAUTION:
Do not leave the laser tool unattended on an accessory without fully tightening the
fastening screw. Failing to do so may lead to the laser tool falling and sustaining
possible damage.
NOTE:
It is best practice to always support laser tool with one hand when placing or
removing laser tool from an accessory.
If positioning over a target, partially tighten the fastening screw, align laser tool, and
then fully tighten
NOTE:
• See LED Descriptions for indications during operation.
• Before operating the laser tool, always make sure to check the laser tool for
accuracy.
• Laser tool will indicate when it is out of compensation range. Reference LED •
Descriptions. Reposition laser tool to be closer to level.
• When not in use, please be sure to power OFF the laser tool and place the
pendulum lock in the locked position.
Power
• Press to turn on the laser tool.
• To turn off the laser tool, repeatedly press until the OFF mode is selected or
press and hold for ≥ 3 seconds to turn off the laser tool while in any mode.
Modes(See figure E)
• Press repeatedly to cycle through the available modes.
Self-Levelling (See figure C )
• The pendulum lock on the laser tool needs to be switched to the unlocked position
to enable self-leveling.
Pulse Mode (See figure F)
• When laser tool is ON, press to turn ON / OFF pulse mode.
• Pulse mode allows to use with laser detector.

APPLICATIONS
TROUBLESHOOTING
9
The self-leveling cross line laser can be placed on the ground,
mounted on an iron work bench / door frame etc. for point marking and
simple alignment by sight, It is ideal for the following applications:
• Hanging pictures, photos, or artwork on walls
• Wallpapering and stencil work
• Framing doors and windows
• Installing electrical wiring and pipes
• Mounting wall fixtures, electrical outlets, switches and lighting
• Installing a drop ceiling
• Painting
• Installing cabinets
• Laying tile and flooring
MAINTENANCE
This laser measuring tool has been designed to be a
low-maintenance tool. However, in order to maintain its performance,
you must always follow these simple directions:
• Avoid exposing the tool to shock, continuous vibration or extreme hot or cold
environment.
• Always store the tool indoors.
• Always keep the tool free of dust and liquids. Use only a clean soft cloth for
cleaning. If necessary, slightly moisten the cloths with pure alcohol or a little water.
• Do not disassemble the laser measuring tool, this will expose the user to
hazardous radiation exposure.
• Do not attempt to change any part of the laser lens.
PROBLEM
The laser line projection
is weak
The laser line is hard to see
Laser line is not projected
Laser line flickers for alert.
Batteries are weak
The tool is out of the
rated operating range
No batteries installed
or batteries are depleted
The surface where the tool,
has been placed is uneven
or the tool is working under,
manual mode
Replace with new batteries
Move the tool closer to be
within the rated operating range
Install new batteries
Place the tool on flat, surface
levels within +/-4 degrees
CAUSE SOLUTION

DISPOSE
10
CAUTION
The batteries must not be disposed with household waste. Care for the
environment and take them to the collection points provided in
accordance with national or local regulations. Dispose of
the product appropriately in accordance with the national
regulations in force in your country. Adhere to the national
and country specific regulations. Product specific treatment
and waste management can be downloaded from our homepage.
WARRANTY
The Instrument P2LC15SG has a two-year warranty. For further
information on this, contact your dealer.
This warranty is void if product is used for commercial purposes. This
warranty is not transferable and
does not cover products damaged by misuse, neglect, accident,
alterations or use and maintenance other than that specified in the
owner's manual. This warranty does not apply to any expendable parts
that can wear from normal use. This warranty excludes any
accessories.
Prexiso AG
Fabrikstrasse 1
CH-8586 Erlen / Switzerland
Internet: www.prexiso-eu.com
Printed in China
Table of contents
Other Prexiso Laser Level manuals