5
Warning
To prevent serious injury, electrical shock or fire:
• Do not operate with bottom plate removed.
• Keep away from rain and moisture.
• Always disconnect all cable connections to and from amplifier before changing fuses and/or
tubes.
• Do not replace fuses with any fuse other than the same type and rating as used by the factory.
• Do not replace tubes without reading instructions.
• Do not replace fuses or tubes if you have any doubt about your ability to do so. We accept no
responsibility for any personal or material damage due to incompetent use or users.
Package Contents
DiaLogue Five Amplifier........................................................................ 1
Power Cord.............................................................................................................................. 1
This Owner's Manual.................................................................................... 1
White Gloves ..................................................................................................................... 1 pair
Tube Complement................................................................................................ 4 x KT88
2 x 12AX7
2 x 12AU7
Main Fuse.................................................................................................................................... 1 x Littelfuse® 213 Series 2.5A Slo-Blo® 5 x 20 mm fuse for
100-120VAC and Littelfuse® 213 Series 1.25A Slo-Blo®
5 x 20 mm fuse for 200-240VAC
Plate Fuse ................................................................................................................................. 1 x Littelfuse® 218 Series 250mA Slo-Blo® 5 x 20 mm fuse
Heavy Metal UL-TR Remote Control ............ 1
Initial Setup
• Carefully remove the DiaLogue Five from its packaging. Use the white gloves to prevent
fingerprint smudges.
• Remove the tube cage by carefully pulling it up and away from the amplifier.
• Remove the protective foam surrounding the tubes.
• Tubes are already installed. Check that each tube is firmly seated in its socket. Use gloves.
• Replace cage back in its place if desired.
• Check to see the power switch is off (down).
• Connect output of preamp with input of poweramp.
• Connect your speaker wires, positive to positive, negative to negative. This unit is non-inverting.
• Plug the powercord into the amplifier, then into the wall socket.
• Switch the preamplifier on and wait for 1 minute to stabilize the circuit.
• Switch the poweramplifier on.
• The tubes will be warmed up and ready to use in about 30 seconds.
PrimaLuna®DiaLogue Five
12
Troubleshooting
Some tips:
• No output. Power is on, but power LED is off and tubes do not light up.
Mains fuse is out. Replace fuse as per instructions on page 11.
• No output. Power LED is on and tubes do light up normally.
Plate fuse may be out. Replace fuse as per instructions on page 11.
If the new fuse goes out immediately after replacement, contact us for further assistance.
• Noise coming from one channel.
Noisy tube. First swap the 12AX7 tubes left to right. If noise follows tube swap, than you have
found the problem tube. If noise does not follow, swap the 12AU7 tubes left to right.
• Hum coming from one channel.
Possible bad output tube. Swap the KT-88 tubes in pairs from right to left. If hum follows the swap,
swap the far left and far right tubes. If the hum returns to the original problem channel, you have
found the problem tube. If not, swap the inside KT-88 tubes left to right.
• Constant low frequency hum at about 50-60 Hz coming from both speakers.
You most probably have a groundloop problem. This might show up with any new component
added, even if you did not have this hum before. It is common in many systems regardless of
brand and easy to address. To confirm you have a ground loop, either unplug the AC cords of all
the other components from electricity, or unplug the cables going to the PrimaLuna you have
hooked up to the amplifier, as well as cable TV or satellite tuner boxes. Leaving only the speakers
attached. If hum stops, call your dealer for a ground loop cure.
• Noise/distortion coming from both channels.
Tubes may be in need of replacement. Read page 10 for tube basics and replacement options.
• Remote control does not function.
Check battery and if necessary, replace with new one (model CR2032).
If you try these possible solutions and problems persist, contact us or your local distributor for further
investigation.
PrimaLuna®DiaLogue Five