Primex XR Levo Series User manual

©2018 Primex. All Rights Reserved. The Primex logo is a registered trademark of Primex. All other trademarks are the property of their respective owners. 12/7/2018. Primex, Inc. |
965 Wells Street | Lake Geneva, WI 53147 | www.primexinc.com | Ph: 1-262-729-4853
XR Levo Series Digital Clocks/Timers
Install Guide
Primex XR 72MHz Synchronized Time Solution

Legal Notice
Copyright ©2018 Primex, Inc. All rights reserved.
Printed in the USA.
Information in this document is subject to change without notice. Software described in this document is furnished under a license
agreement or nondisclosure agreement. The software may be used or copied only in accordance with the terms of those
agreements.
No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic,
mechanical or otherwise, for any purpose, without the prior written permission of Primex, Inc.
Primex, Inc.
Primex is a leading provider of synchronized time and environmental monitoring solutions. Our solutions automate and maintain
facility compliance, increase efficiencies, enhance safety and reduce risk for organizations in the healthcare, education,
manufacturing and government vertical markets.
Worldwide Headquarters
965 Wells Street, Lake Geneva, WI 53147
Phone: 1-262-729-4853 | email: info@primexinc.com | www.primexinc.com
2XR Levo Series Digital Clocks/Timers Install Guide

Regulatory Compliance
FCC/IC Product Compliance
This device complies with part 15 of the FCC rules as well as with Industry Canada.
Operation of this device is subject to the following two conditions:
lThis device may not cause harmful interference.
lThis device must accept any interference that may cause undesired operation.
3

Important Safety Instructions
READ ALL INSTRUCTIONS BEFORE INSTALLATION, OPERATION, OR MAINTENANCE OF PRODUCT.
Important Safety Instructions
READ ALL INSTRUCTIONS BEFORE INSTALLATION, OPERATION, OR MAINTENANCE OF PRODUCT.
Some of the following information may not apply to your particular product model; however, as with any electronic product,
precautions should be observed during installation, operation, and maintenance.
lInstallation must conform to state or local building codes and ordinances.
lInstallation or maintenance should be performed only by qualified personnel as defined in the Local Electrical Code.
lMount in location where device will not readily be subject to tampering.
lAny wiring instructions must be followed precisely. Failure to do so could cause permanent equipment damage.
lTo avoid possible electric shock or damage to the device, disconnect power source before installation or servicing.
lDo not install or use device near water. To reduce the risk of electrical shock, do not expose device to rain or moisture. Device
must not be exposed to dripping or splashing and no objects filled with liquids, such as vases, must be placed on the device.
lDevice is designed for indoor use only. Operating outdoors, or in wet areas, is an electrical hazard and may damage the
equipment while nullifying the warranty.
lDevice is cleanable with a cloth moistened with water or a common disinfectant. Be sure to test any cleaning solutions on a small
area of the clock before using it on the entire device.
lFor healthcare facilities, devices are not intended for patient use and must not be installed within 6ft (2m) of patient contact.
AC-Power Pluggable Clock/Timer Models
lAC main power supply must be disconnected while installing or performing maintenance of any device. To completely
disconnect the power input, the main plug should be disconnected from the main socket outlet completely.
lThe main socket outlet must provide a protective earthing connection where the outlet has a protective earth (ground)
connection.
lMain plug is used as disconnect device and it should remain readily operable during intended use.
AC-Power Hardwired Clock/Timer Models
lAC power must be supplied from a circuit that has a resettable circuit breaker.
lAC mains power supply must be disconnected while installing or performing maintenance of any device. Open the circuit
breaker supplying the device before attempting installation, maintenance, or repairs.
4

About this Guide
Purpose
This guide is intended to provide the instructions and information required to install and operate Primex Levo Series Digital
Clocks/Timers.
Typographical Conventions
This guide includes notes, cautions, and warnings content that highlights important messages.
Typeface Indicates
Note Indicates something important or useful.
Caution Indicates a command or procedure may have an unwanted or undesirable result.
Warning Indicates a command or procedure that could be dangerous to system or device.
Example Provides an example of how the topic can be configured or used.
5

Contents
Specifications 9
Timer Switch Control Specifications 10
Configure Display Settings 14
Install Levo Series Digital Clock/Timer 17
Installation Requirements 17
120 VAC Wiring & Power Specifications 18
24 VAC Wiring & Power Specifications 19
Tilt-Bracket and Surface Mount Mounting Dimensions 20
Surface Mount Installation 22
Tilt Bracket Installation 24
Remove Clock/Timer from Bracket 26
Dual Mount Installation 27
Dual Mount Dimension Specifications 30
Remove Digital Clock/Timer from Dual Mount Bracket 31
Flush Mount Installation 32
Flush Mount Dimension Specifications 35
Remote Antenna Installation 36
Timer Switch Control Installation 38
Code Blue Timer Operation 40
Timer Switch Control Specifications 41

8

Specifications
Listed below are the components and specifications of a Levo Series Digital Clock/Timer.
Components
lKey-hole mount (2); secure mount
lPower supply
lPower cord with 2-prong plug
lPower cord strain relief assembly
lSetting panel; configure clock settings and location of Reset button
lCode Blue Timer: 4 pin connector 30 in. (76.2 cm) length; RJ 11 jack for connection from the timer to the timer control switch
The figure below illustrates the back of a Levo Series Digital Clock/Timer and its components.
Levo Series Digital Clock/Timer Specifications
Parameter Specification
LED Display Highly visible 7-segment LED digits
2.5" model: 2.5” (6.4 cm) diagonal (hours and minutes), 1.4" (3.6 cm) diagonal (seconds)
4" model: 4.6” (11.7 cm) diagonal (hours and minutes), 2.5” (6.4 cm) diagonal (seconds)
LED Display Dimmer 100%, 75%, 50%, 25%
9XR Levo Series Digital Clocks/Timers Install Guide

Parameter Specification
Time Display 12- or 24-hour time
PM indicator light
Alternating time and date display option
Hour Offset +/- 24 hours
Receiver Sensitivity
(Decode)
< -110dBm
Power Supply 100-240 VAC/ 50–60 cycle. Supplied with 10 ft (3.0 m) cord with plug and UL/cUL listed power
supply
24VAC model: 18-28VAC/ 50–60 cycle. Supplied with a 10 in. (25 cm) cord with pigtail and power
supply
Power Outage Memory
Backup
In the event of a power outage, its internal memory maintains the correct time for a minimum of
one hour without power; requires a minimum one hour of charging time.
Enclosure ABS plastic
Junction box: UL listed (UL 50E 1st Ed; listing number E469550)
Storage Temperature Range -20° to 185° F (-29° to 85° C)
Operating Temperature
Range
32° to 194° F (0° to 35° C)
Code Blue Timer Input 5-120 VAC/ DC /DC or dry contact input
Code Blue and Elapsed
Timer Audible Beep Option
Frequency 3KHz +/-0.5KHz
Certification FCC/IC/CE marked
All specifications are subject to change without notice.
Timer Switch Control Specifications
The Primex 3 button Timer Switch Control provides the method manage events for both the Elapsed and Code Blue Timer. Elapsed
Timer count down or count up events are triggered manually by a user from the timer switch control buttons. Code Blue Timer
events are triggered by the input of the wired connection to the code blue system and the timer switch control allows a user to
10

pause a code blue event.
lDesigned to fit inside a single gang box (not supplied); typically 2 1⁄4 in. x 2 3⁄4 in. x 4 in. (11.45 cm x 6.99 cm x 10.15 cm).
lTimer Switch Control can simultaneously activate two connected timers for even more accurate event management.
lTimer Switch Control membrane switch and wall plate clean easily and resist common cleaners and disinfectants. Be sure to
test any cleaning solutions on a small area.
Elapsed Timer - Timer Switch Control operating specifications
The timer has three operating modes and a set state. The Timer Switch Control DISPLAY button sets the timer into each mode. The
RESET button sets the timer into its set state, allowing a user to set the start time for a count up or count down event.
Clock Mode Count-Up Mode Count-Down Mode Set State
10:45 02
Displays current synchronized
time
0.0:00 00
Decimal lit after the 10hr
digit
99:59 59.
Decimal lit after the 1 sec
digit
Set the start time for count
event.
Elapsed Timer - Count Mode operating specifications
The Timer Switch Control allows a user to start, stop, pause and reset the timer. When not in a count mode, the timer displays its
synchronized time.
Pressing the
button... Clock Mode Count Up Mode Count Down Mode
DISPLAY
EXIT
Pressing and releasing the DISPLAY button scrolls through the various modes in the following order:
1. Clock Mode
2. Count Up Mode
3. Count Down Mode
STOP/START
INCREMENT
Ignored Controls the count up event while in count up
mode.
If the count event is started, pressing and
releasing the STOP/START button stops and
pauses the event.
If the count event is stopped/paused, pressing
and releasing the STOP/START button resumes
the event.
Controls the count down event while in count
down mode.
If the count event is started, pressing and
releasing the STOP/START button stops and
pauses the event.
If the count event is stopped/paused, pressing
and releasing the STOP/START button resumes
the event.
11 XR Levo Series Digital Clocks/Timers Install Guide

Pressing the
button... Clock Mode Count Up Mode Count Down Mode
RESET
SET/CHANGE
Ignored Pressing and releasing the RESET button once
automatically stops and resets the count event
to its preset start time.
Or
Holding the RESET button puts the timer into
SET STATE.
Pressing and releasing the RESET button once
automatically stops and resets the count event
to its preset start time.
Or
Holding the RESET button puts the timer into
SET STATE.
Elapsed Timer - Set State operation specifications
The Set State is used to set the start time for a count up or count down event. Enter the Set State by holding the RESET button
while in count up or count down mode.
In this state:
lThe text labeled on the bottom of the switch control button is applicable (SET/CHANGE, INCREMENT, EXIT).
lThe dash, colon, and decimal points are not displayed.
lThe digit that is currently being set will flash.
Pressing the
button... Count Up Mode Count Down Mode
DISPLAY
EXIT
Exits Set State Saves the start time and exits the Set State
STOP/START
INCREMENT
Increments the selected digit Increments the selected digit
RESET
SET/CHANGE
Holding the SET/CHANGE button for 3 seconds enters
the set state, which is indicated by “ _ _:_ _ _ _” on the
display.
The selected digit will blink.
Pressing SET/CHANGE again to select the next digit.
Holding the SET/CHANGE button for 3 seconds enters
the set state, which is indicated by “ _ _:_ _ _ _” on the
display.
The selected digit will blink.
Pressing SET/CHANGE again to select the next digit.
Code Blue Timer - Timer Switch Control operating specifications
The Timer Switch Control allows a use to halt a code blue event.
12

Pressing the
button... Running Mode Halted Mode
DISPLAY
EXIT
Ignored Places display back in clock mode
Holding down DISPLAY for a minimum of four seconds shows the last code blue time.
RESET
SET/CHANGE
Ignored Ignored
STOP/START
INCREMENT
Halts the code blue event count at the moment the button is
pressed.
Ignored
13 XR Levo Series Digital Clocks/Timers Install Guide

Configure Display Settings
Levo Series Digital Clocks and Timers have a dip switch control panel that sets its display settings.
How to access setting panel
To change the factory default settings, from the back side of the clock remove the small rectangular access panel. Setting
changes can be made while the clock/timer is ON and changes will take effect within a few seconds.
NOTE
When power is first applied to the clock/timer or the reset button is pushed, a decimal point will flash for approximately
three minutes while its receiver is turned on to search for a Transmitter signal. If the clock does not receive valid time data
from the Transmitter for 3 days, the red colon on the clock will flash.
Set LED dimmer display
The LED display is set to 100% by factory default.
To dim the LED by 25%, set the OPTIONS, DIM switch 1 to the OFF position and DIM switch 2 to the ON position, as illustrated
below.
To dim the LED by 50%, set the OPTIONS, DIM switch 1 to the ON position and DIM switch 2 to the OFF position, as illustrated
below.
To dim the LED by 75%, set the OPTIONS, DIM switch 1 to the ON position and DIM switch 2 to the ON position, as illustrated
below.
14

Set alternating time/date
To set the display of a to alternate between the current time and date, set the HR OFFSET- Time/Date switch (1) to the ON
position, as illustrated below.
Set display to 24-hour time
To display24-hour time, set the HR Offset - 12/24 HR switch (2) to the ON position, as illustrated below.
Set PM indicator
To enable the PM dot indicator,set the OPTIONS - PM DP switch (6) to the ON position, as illustrated below.
Set offset hours
The Clock/Timer displays the time received from the Transmitter. The hour offset is for application use when the clock/timer is to
display the time for another Time Zone.
15 XR Levo Series Digital Clocks/Timers Install Guide

By moving the appropriate “HR OFFSET” dip switch(s) and the direction (+/-) dip switch, any full-hour time can be displayed. The
“HR OFFSET” switch designates how many hours are offset from the current Transmitter Time Zone.
The clock reads the hour offset on start up, when the RESET button is pushed, and each time the clock receives data from the
Transmitter for the offset hours to go into effect.
Set audible buzzer (timer models only)
The audible buzzer is only on the count-up and count-down timer function. To enable the buzzer feature, set the OPTIONS -
Buzzer switch (3) to the ON position, as illustrated below.
Set Programmable Timer mode (programmable timer only)
For Programmable Timer models, the timer schedule is configured in the Primex Event Scheduler Pro software to the schedule ID
controller 24. The schedule is downloaded from the Event Scheduler Pro to the system Transmitter, allowing the Transmitter to
broadcast the schedule.
To enable a programmable timer to receive the broadcast schedule from the Transmitter, set the PT/TC Switch (5) to the ON
position, as illustrated below.
16

Install Levo Series Digital Clock/Timer
Installation Requirements
lRefer to the Important Safety Instructions before installing, operating or performing maintenance of clocks.
lBefore installing a clock, verify the system Transmitter is operating properly and sending a signal with adequate building
coverage.
Broadcast (Transmit) Schedule Transmitter with Internal Antenna: broadcasts its synchronized time continuously to the system
clocks and devices.
Broadcast (Transmit) Schedule Transmitter with External Antenna: broadcasts its synchronized time to the system clocks and
devices from the 39th to the 6th minute of the next hour and changes to a standby mode during the 7th to the 38th minute of
the hour (standard broadcast schedule). During initial power-up, the Transmitter broadcasts for 8 consecutive hours. After the
8 hour power-up period, the Transmitter reverts to its timed broadcast schedule.
lClocks must be installed at a location within adequate transmission range of the Transmitter.
lVerify the clock's settings have been configured before the clock is installed.
lAny damage to the clock due to improper wiring voids the warranty. It is at Primex discretion as to whether damage to the
clock was caused by improper wiring.
17

120 VAC Wiring & Power Specifications
120 VAC Wiring Requirements
Levo Series Digital Clocks/Timers are shipped from the factory with a power supply and power cord with a two prong plug.
The power plug may be removed and cord cut to length for hardwired (pigtail) installation. Pigtail installation requires a 120V~
power line in a junction box installed by a licensed electrician. Leave a minimum of 6 inches (15 cm) of cord inside the junction
box.
120 VAC Power Requirements
Clock Type Weight Max. Current Draw Height (A) Width (B) Depth (C)
2.5" (6.4 cm), 6-digit 2.0 lbs. (0.9 kg) 230 mA 5.0" (12.7 cm) 13.75" (34.9 cm) 2.2" (5.6 cm)
2.5" (6.4 cm), 4-digit 1.8 lbs (0.8 kg) 170 mA 5.0" (12.7 cm) 10.8" (27.4 cm) 2.8" (5.6 cm)
4" (10.16 cm), 4-digit 3.9 lbs. (1.8 kg) 240 mA 8.0" (20.3 cm) 17.9" (45.5 cm) 2.4" (6.1 cm)
4" (10.16 cm), 6-digit 4.6 lbs (2.1 kg) 260 mA 8.0" (20.3 cm) 2.3" (59.3 cm) 2.4" (6.1 cm)
18 XR Levo Series Digital Clocks/Timers Install Guide

24 VAC Wiring & Power Specifications
Follow all National and Local Building Codes when installing clocks.
24 VAC Wiring Requirements
All clocks should be connected to a single power source. If multiple power sources are needed to accommodate the load of the
clocks, all of the power sources should have the same rating and be installed on separate branch circuits. Never install different
size power sources on the same branch circuit.
lFor installations where 24 VAC wiring exists: gauge/length of the wire and rating for the supply transformer should be verified
to ensure adequate current supply and voltage for all connected devices.
lFor new installations: supply wire gauge should be determined to ensure acceptable voltage drop based on installed length
from the supply transformer to most distant clock to ensure minimum voltage (18 VAC) is assured.
Use two wire nuts, sized appropriately for the gauge of wire, to secure building supply wires to wires extending from clock power
supply.
24 VAC Power Requirements
Clock Type Weight Maximum Current* Average Current** Height (A) Width (B) Depth (C)
2.5" (6.4 cm), 4-digit 1.8 lbs (0.8 kg) 1A 0.7A 5.0" (12.7 cm) 10.8" (27.4 cm) 2.8" (5.6 cm)
2.5" (6.4 cm), 6-digit 2.0 lbs. (0.9 kg) 1.2A 0.8A 5.0" (12.7 cm) 13.75" (34.9 cm) 2.2" (5.6 cm)
4" (10.16 cm), 4-digit 3.9 lbs. (1.8 kg) 1.1A .73A 8.0" (20.3 cm) 17.9" (45.5 cm) 2.4" (6.1 cm)
4" (10.16 cm), 6-digit 4.6 lbs (2.1 kg) 2.8A 1.5A 8.0" (20.3 cm) 2.3" (59.3 cm) 2.4" (6.1 cm)
*Maximum Current for a single clock running at 24 VAC.
**With all segments on, test only.
NOTE
Peek start current (in-rush) could be as much as three times stated values.
19

Tilt-Bracket and Surface Mount Mounting Dimensions
Dimension D - clock screw hole spacing
Dimension E - distance to wall surface for 4° mounting bracket
Dimension F - distance to wall surface for 18° mounting bracket
Dimension G/H - mounting bracket screw hole spacing
Single Digital Clock/Timer mounting dimensions illustration
Single Digital Clock/Timer mounting dimensions
Clock/Model A B C D E F G H
2.5” 4-digit - 4° bracket 4.8” 10.6” 2.1” 6.0” 0.38” – 0.63” N/A 8.0” 2.5”
2.5” 6-digit - 4° bracket 4.8” 13.6” 2.1" 6.0” 0.38” – 0.63” N/A 8.0” 2.5”
2.5” 4-digit - 18° bracket 4.6" 10.6" 2.2" 6.0" N/A 2.1" 9.5" 2.5"
2.5” 6-digit - 18° bracket 4.6" 13.6" 2.1" 6.0" N/A 2.1" 9.5" 2.5"
20 XR Levo Series Digital Clocks/Timers Install Guide
Other manuals for XR Levo Series
1
Table of contents
Other Primex Timer manuals
Popular Timer manuals by other brands

Ascon Pool
Ascon Pool C1200 quick start guide

mr. steam
mr. steam 99216DIG Installation and operating manual

Green Brook
Green Brook T17B Installation & operating instructions

Silent Gliss
Silent Gliss 11093 User manual and setting instructions

red lion
red lion C48T instructions

Powerplus
Powerplus LR1130 manual

Timeguard
Timeguard NTT06 Installation & operating instructions

gebatronic
gebatronic 941.DCZ3.00 Installation and operation manual

Timeguard
Timeguard NTT03 Installation & operating instructions

Prime Wire & Cable
Prime Wire & Cable TNINL2412 Step-By-Step Instructions

Steren
Steren SWI-630 instruction manual

Webasto
Webasto BlueHeat 1533 manual