- 9 -
INFORMATION DISPLAYED ON SCREEN:
Timer -Indicates the time the system
has been working and starts measuring
a range of time (minutes: seconds), after
an hour of operation this changes its time
reference to: (hour: minute).
You can also view here when the
membrane is in fast ush mode.
It will display a countdown in seconds.
When the system is on (stand by) but
has the power On- the control will save
information showing how long the System
has been operating. If for any reason the
system does not get an electrical supply
the information stored previously will be lost.
After 9999 hours, the timer will return to
000 hours.
TDS - Shows the quality of product water
in TDS PPM being obtained at that time.
LOW : When this appears on the screen,
it indicates low pressure in the system.
Additionally, on the control box, a Yellow
light will illuminate when there is low
pressure as a visual reference.
FLUSH - When membrane ush
is activated, droplets above the word
FLUSH are displayed.
MAIN PUMP - This display represents
the high-pressure pump of the System
is activated. When Blades are in motion
it means the pump is ON. In addition,
the green light on the control box will
indicate that the system is in operation.
FULL - Appears on the screen when a signal
is received that the storage tank is full.
SETTING PARAMETERS:
P1 -Time Setting adjustment for the duration of the membrane
fast ush; 15 sec, 30 sec, 45 sec, 60 sec.
P2 -Setting for adjusting the start-up delay time for the start if
the system receives any signal by the low pressure or high level
switch; 0 sec = o, 5 sec, 10 sec, 15 sec, 20 sec.
P3 -
(OPTIONAL FEATURE – SKIP IF FAST FLUSH WAS NOT PURCHASED
WITH THIS FEATURE) Select frequency or time between each
membrane fast ush when the system is operating; 0 = OFF
(OFF function), 1 hr, 2 hr, 3 hr, 4 hr, 5 hr, 6 hr 7 hr, 8 hr, 9 hr,
10 hr 11 hr 12 hr. (only used when purchasing a system with
fast ush integrated)
P4 -(OPTIONAL FEATURE – REQUIRES PROGRAMMING)
Select frequency or time between each membrane ush
when the system is in standby; 0 = OFF (OFF function),
12 hr, 24 hr, 36 hr, 48 hr, 60 hr, 72 hr, 84 hr, 96 hr.
P5 -TDS range selection (set point) if you want to send an
alarm signal indicating that water quality has changed;
0 = OFF (function o), it can be adjusted 10 PPM to 200 PPM.
The control will trigger an alarm indicating that the quality
of water changed, then the alarm will repeat every hour,
until you identify and correct the problem with the TDS.
P6 -Parameter based on the sensitivity setting of the TDS meter.
The lower this parameter the best sensitivity will be for this sensor.
It is suggested to be set to less than 15 PPM after calibration.
The last screen in the parameter settings records the last 5
events of "non operation" presented by the system and how
long it was o. Up and Down Arrow reads T1, T2, T3, T4 and T5
are records in the memory of the “non operation”and indicates
which switch was deactivated.
Parameter settings recommended for basic automation:
P1 = 15 P2 = 0 P3 = 0
P4 = 0 P5 = 50 P6 = 15
1:0 1
TIMER
158
T.D.S
LOW
FULL
MAIN
PUMP
FLUSH
CONTROLLER PROGRAMMING