PRO Light ELUM120A User manual

Order codes: ELUM120A
Tour Batten TW
User Manual

www.prolight.co.uk Tour Batten TW User Manual
2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablemainssupplyvoltageis
between100~240VAC,50/60Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreached
roomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProLight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• Thislightingxtureisforprofessionaluseonly-itis
notdesignedfororsuitableforhouseholduse.The
productmustbeinstalledbyaqualiedtechnicianin
accordancewithlocalterritoryregulations.Thesafetyof
theinstallationistheresponsibilityoftheinstaller.The
xturepresentsrisksofsevereinjuryordeathduetore
hazards,electricshockandfalls.
• Warning!RiskGroup2LEDproductaccordingto
EN62471.Donotviewthelightoutputwithoptical
instrumentsoranydevicethatmayconcentratethebeam.
• WARRANTY:Twoyearsfromdateofpurchase.

www.prolight.co.uk Tour Batten TW User Manual
3
Product overview & technical specications
ThisTourBattenTWfeatures10x10WwarmwhiteLEDsandavariablecolourtemperaturebetween
1600K–2900K.ThetemperaturecanbesetviatherearmenuorDMX.Whendimmed,thexturecanemulatea
traditionalhalogenlampwithanorangeglowsimilartoasunstrip,whilstthe18°beamproducesasmoothwash
orblindereffect.
Tour Batten TW
Specications Tour Batten TW
Powerconsumption 110W
Powersupply 100~240V,50/60Hz
Dimensions 139x1082x130mm
Weight 6.5kg
Ordercode ELUM120A
1082mm 130mm
1000mm 78.2mm
1042mm
139mm
92.8mm
01-PowerindicatorLED
02-RDM/DMXindicatorLED
03-LCDdisplay
04-Functionbuttons
05-5-PinDMXinput
06-5-PinDMXoutput
07-PowerCONinput
08-PowerCONoutput
09-FuseT3.15A250V
10-Powerswitchon/off
Inthebox:1 x xture,
2 x end brackets,
1 x power cable
& 1 x user manual
RDM/DMX OUTPUT
POWER OUTPUT (15A Max.)
RDM/DMX INPUT
POWER INPUT (15A Max.)
100-240V~50/60Hz
MENU UP ENTER
RDM/DMX
POWER
DOWN
PRESS & HOLD “MENU” AND “ENTER” TO UNLOCK
1 = Ground
2 = Data -
3 = Data +
4 = NC
5 = NC
1 = Ground
2 = Data -
3 = Data +
4 = NC
5 = NC
POWER
FUSE:
T3.15A 250V
TOUR BATTEN TW
www.prolight.co.uk
CAUTION RISK OF ELECTRIC SHOCK
DO NOT OPEN THIS FIXTURE
WARNING: THIS PRODUCT MUST BE EARTHED
RDM/DMX OUTPUT
POWER OUTPUT (15A Max.)
RDM/DMX INPUT
POWER INPUT (15A Max.)
100-240V~50/60Hz
MENU UP ENTER
RDM/DMX
POWER
DOWN
PRESS & HOLD “MENU” AND “ENTER” TO UNLOCK
1 = Ground
2 = Data -
3 = Data +
4 = NC
5 = NC
1 = Ground
2 = Data -
3 = Data +
4 = NC
5 = NC
POWER
FUSE:
T3.15A 250V
TOUR BATTEN TW
www.prolight.co.uk
CAUTION RISK OF ELECTRIC SHOCK
DO NOT OPEN THIS FIXTURE
WARNING: THIS PRODUCT MUST BE EARTHED
RDM/DMX OUTPUT
POWER OUTPUT (15A Max.)
RDM/DMX INPUT
POWER INPUT (15A Max.)
100-240V~50/60Hz
MENU UP ENTER
RDM/DMX
POWER
DOWN
PRESS & HOLD “MENU” AND “ENTER” TO UNLOCK
1 = Ground
2 = Data -
3 = Data +
4 = NC
5 = NC
1 = Ground
2 = Data -
3 = Data +
4 = NC
5 = NC
POWER
FUSE:
T3.15A 250V
TOUR BATTEN TW
www.prolight.co.uk
CAUTION RISK OF ELECTRIC SHOCK
DO NOT OPEN THIS FIXTURE
WARNING: THIS PRODUCT MUST BE EARTHED
RDM/DMX OUTPUT
POWER OUTPUT (15A Max.)
RDM/DMX INPUT
POWER INPUT (15A Max.)
100-240V~50/60Hz
MENU UP ENTER
RDM/DMX
POWER
DOWN
PRESS & HOLD “MENU” AND “ENTER” TO UNLOCK
1 = Ground
2 = Data -
3 = Data +
4 = NC
5 = NC
1 = Ground
2 = Data -
3 = Data +
4 = NC
5 = NC
POWER
FUSE:
T3.15A 250V
TOUR BATTEN TW
www.prolight.co.uk
CAUTION RISK OF ELECTRIC SHOCK
DO NOT OPEN THIS FIXTURE
WARNING: THIS PRODUCT MUST BE EARTHED
RDM/DMX OUTPUT
POWER OUTPUT (15A Max.)
RDM/DMX INPUT
POWER INPUT (15A Max.)
100-240V~50/60Hz
MENU UP ENTER
RDM/DMX
POWER
DOWN
PRESS & HOLD “MENU” AND “ENTER” TO UNLOCK
1 = Ground
2 = Data -
3 = Data +
4 = NC
5 = NC
1 = Ground
2 = Data -
3 = Data +
4 = NC
5 = NC
POWER
FUSE:
T3.15A 250V
TOUR BATTEN TW
www.prolight.co.uk
CAUTION RISK OF ELECTRIC SHOCK
DO NOT OPEN THIS FIXTURE
WARNING: THIS PRODUCT MUST BE EARTHED
06 05
08
01
02
04
03
07
09
10
0m 1m 2m 3m 4m 5m
18° - Lux 2140 1731 769
20°
433 277
•2yearwarranty
•10x10WwarmwhiteLEDs
•Beamangle:18°
•1731Lux@2m
•Pixelmappingcapabilities
•DMXchannels:8bit-
1/2/5/10/6
•16bit-2/4/10/20
•Static,autorunandmaster/
slavemodes
•0-100%16bitdimming
•RDM(RemoteDevice
Management)
•4pushbuttonmenuwith
LCDdisplay
•PowerCONinput/output
•5-PinXLRinput/output
•Convectioncooled

www.prolight.co.uk Tour Batten TW User Manual
4
Operating instructions
Main Menu Sub Menu Options/Values Description
DMX
Channel
01/8Bit 1channelmode-8bit
DMXChannelSetting
02/16Bit 2channelmode-16bit
02/8Bit 2channelmode-8bit
04/16Bit 4channelmode-16bit
05/8Bit 5channelmode-8bit
10/16Bit 10channelmode-16bit
10/8Bit 10channelmode-8bit
20/16Bit 20channelmode-16bit
06/8Bit 6channelmode-8bit
Address 001-512 DMXAddressSetting
NoDMX
OFF
FunctionswhennoDMXsignalHold
Program
Glide ON SwitchingDMXfadetoonactivates
ashortdelayonDMXcommands
OFF
Chase
Program Program:01-Program:16/
Program:Auto/Program:Full Program
Master 000-100 Masterdimmer
Speed 01-100 ProgramSpeed
FadeTime 000-100 ProgramFade
IMPORTANT! PLEASE NOTE:TheLCDdisplayforthisxturehasamenulockingfunctionwhere
after30secondsofinactivityitwilllock.Tounlockthemenuholdthe“MENU”and“ENTER” buttons
for3seconds.

www.prolight.co.uk Tour Batten TW User Manual
5
DMX mode:
OperatinginaDMXcontrolmodeenvironmentgivestheuserthegreatestexibilitywhenitcomes
tocustomisingorcreatingashow.Inthismodeyouwillbeabletocontroleachindividualtraitofthe
xtureandeachxtureindependently.
ToaccesstheDMXchannelmode,pressthe“MENU”buttononthefrontoftheunittoshow
“Address” ontheLCDdisplay.Pressthe“ENTER”buttontoshow“Channel” ontheLCDdisplay.
Nowusethe“UP”and“DOWN”buttonstochooseoneofthechannelmodes;
1/2/5/10/6-8bit,2/4/10/20-16bit(seechartonpage4).
Pressthe“ENTER”buttontoconrmthesetting.
ToaccesstheDMXaddressmode,pressthe“MENU”buttononthefrontoftheunittoshow
“Address” ontheLCDdisplay.Nowthe“UP”and“DOWN”buttonstosettherequiredDMXaddress.
Pressthe“ENTER”buttontoconrmthesetting.
ToaccesstheDMXbitsetting,pressthe“MENU”buttononthefrontoftheunittoshow
“Address” ontheLCDdisplay.Pressthe“ENTER”buttontoshow“Glide” onthe
LCDdisplay.Nowthe“UP”and“DOWN”buttonstosettheDMXfade“ON”or“OFF”.
Pressthe“ENTER”buttontoconrmthesetting.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Operating instructions
Channel Value Function
1 000-255 LEDs1-10dimmer(0-100%)
1 channel mode - 8 bit:
Channel Value Function
1 000-255 LEDs1-5dimmer(0-100%)
2000-255 LEDs6-10dimmer(0-100%)
2 channel mode - 8 bit:
Channel Value Function
1 000-255 LEDs1-2dimmer(0-100%)
2000-255 LEDs3-4dimmer(0-100%)
3000-255 LEDs5-6dimmer(0-100%)
4 000-255 LEDs7-8dimmer(0-100%)
5 000-255 LEDs9-10dimmer(0-100%)
5 channel mode - 8 bit:
Channel Value Function
1high8byte
2low8byte
00000-
65535
LEDs1-10dimmer
(0-100%)
2 channel mode - 16 bit:
Channel Value Function
1high8byte
2low8byte
00000-
65535
LEDs1-5dimmer
(0-100%)
3high8byte
4low8byte
00000-
65535
LEDs6-10dimmer
(0-100%)
4 channel mode - 16 bit:
Channel Value Function
1high8byte
2low8byte
00000-
65535
LEDs1-2dimmer
(0-100%)
3high8byte
4low8byte
00000-
65535
LEDs3-4dimmer
(0-100%)
5high8byte
6low8byte
00000-
65535
LEDs5-6dimmer
(0-100%)
7high8byte
8low8byte
00000-
65535
LEDs7-8dimmer
(0-100%)
9high8byte
10low8byte
00000-
65535
LEDs9-10dimmer
(0-100%)
10 channel mode - 16 bit:
Table of contents
Other PRO Light Dj Equipment manuals

PRO Light
PRO Light CP-64U HP User manual

PRO Light
PRO Light Color Fusion User manual

PRO Light
PRO Light EQUINOX User manual

PRO Light
PRO Light elumen8 User manual

PRO Light
PRO Light EQLED052 User manual

PRO Light
PRO Light LED-707 User manual

PRO Light
PRO Light TRANSCENSION DMX OPERATOR 2 User manual

PRO Light
PRO Light LUMA700 User manual

PRO Light
PRO Light TRIBE LUMIPAR 12IP User manual