Pro XK3190-DS3 User manual

XK3190-DS3
Weighing Display Controller(control
system weighing indicator)
Operation Command
V 1.01

Chapter 1 Technical Parameter 1
Chapter2 Installation 2
I. Front and Back Functional Schematic Diagrams of Indicator
II. Connection between Lload Cell and Indicator
III. Connection between Printer and Indicator
IV. Connection of Scoreboard
V. Connection of Serial Communication Interface
Chapter3 OperationMethod 8
I. Startup and Auto Startup Zero Setting
II. Manual Zero Setting (Semi-auto Zero Setting)
III. Tare Deduction Function
IV.SetDateandTime
V.UseofBattery
VI.InternalCodeDisplay
VII.SaveDataRecord
VIII. Operation of Printing
IX. Report Printing
X. Data Inquiry
XI. Operation of Eeliminating Record
XII. Input Method of Saved Tare
XIII. Power Saving Function
XIV. Adjustment of Display Brightness
XV. Switch between Gross Weight and Net Weight
Chapter4 MaintenanceandNotes 16
Chapter5 InformationCue 17
Appendix 18
Dearcustomers,
Pleasereadthiscommandbeforeusing
the indicator.

X K 3 1 9 0 –DS3
(1)
Chapter 1 Technical Parameter
1.Model: XK3190-DS3
2. Interface of digital load cell(s):
Interface mode: RS485
Transmission distance: ≤1000 meter
Transmission speed: 9600 baud
Signal power source: DC10V,≤400mA
Interface capability: ≤16 digital load cell(s)
Compatible protocol: Digital module protocol of the Company
Supporting
manufacturers:
Zhonghang Electronic Measuring Indicators Co., Ltd.,
ZEMIC Guangzhou Electrical Measuring Indicators Factory,
Ningbo BENUI Electric Co., Ltd.BENUI and Ningbo Board
Electric Co., Ltd. etc. manufacturers support the digital
sensor (load cell) of protocol of the Company.
Note: Each manufacturer may use different protocol.
3. Display: 7-digit super brightness white light LED display, 10 status
indicating lights.
4. Keyboard: Numberkeys 0~9
Functionkeys 24(10compositekeyswithnumberkeys)
5. Clock: For displaying year, month, date, hour, minute, second, leap year/month
automatically, without the influence from power break down.
6. Scoreboard display interface
Transmission mode Serial output, 20mA electric current loop signal
(constant-current source output)
Transmission baud rate 600
Transmission distance ≤2000 meters
7. Serial communication interface
Transmission mode RS232/RS422 (optional)
Baud rate 600/1200/2400/4800/9600 optional
Transmission distance RS232 ≤30 meters; RS422 ≤1200 meters
8. Printing interface
The indicator is equipped with a standard parallel printing interface
for connecting with ESPON LQ-300K(+), Panasonic KX-P1131
and KX-P1121 etc. wide line printers.
9. Data storage
1000 sets of vehicle numbers and tare weights, 201 sets of article
numbers and 1001 sets of weighing records.
10. Application environment
Power source AC 100~264V, 50~60Hz
DC 12V7AH battery (optional)
Operating temperature -10 ~ 40℃℃
Storage and transportation temperature -25 ~ 55℃℃
Relative humidity ≤85%RH
Preheat time ≤30 minutes
Fuse 0.5A
11. Shape (mm) 290×75×210 (do not contain the size of bracket)
12. Self weight about 2.7 kilograms

X K 3 1 9 0 –DS3
(2)
Chapter 2 Installation
I. Front and Back Function Schematic Diagrams of Indicator
(Figure 2-1) Front Functional Schematic Diagram
(Figure 2-2) Back) Function Schematic Diagram
II. Connection between Load cell and Indicator
XK3190-DS3 is a digital weighing indicator. Therefore,
it can only be connected with digital load cell
(indicator). For easy indication, the product is called
as load cell (indicator) for short.
1. The load cell is equipped with 9 core connector for
connection. Meanings of all pins are marked in Figure
2-3.
(Figure 2-3) Digital load cell interface
Shield-T-R+T+R
+V-V
Battery
Capacit
Internal Code|Auto|Gross Weight|Net Weight|Stable|Tare|Null Position
Address|Calibration| Vehicle No.| Article No.| Save Tare|Check
Angle modulation|Set|Supplementary Printing|Clock| Tare Setting|Input
Angle modulation|Set|Supplementary Printing|Clock| Tare Setting|Input
Self-calibration|Gross/Net Weight| Accumulative Printing|Clear|Weighing
Test|Brightness|Printing|F1|Tare|Zero
XK3190-DS3 Digital Weighing Display Controller
Interface of load cell
Interface of communication and
scoreboard
Interface of printerSocket of DC power
Power switch Socket of AC power
Calibration switch

X K 3 1 9 0 –DS3
(3)
2. Load cell interface of XK3190-DS3 adopts the interface mode of four-wire RS485 mode.
Table 2-1-1 Digital Load Cell Connection
III. Connection between Printer and Indicator
1. The printer is equipped with standard parallel output interface and 25-core RS232 connector
assembly. See definition of its pins in Figure 2-4.
(Figure 2-4) Printer interface signal
2. Printing directions:
▲! The printer may be used only after completing relevant settings. All relevant
paremeters of the printer must be set before using it.
▲! Connection between printing interface output pin of the indicator and the printer must
be accurate without fault. Only dedicated connecting wire for printing may be used.
(Indicator must be connected with printer by appropriative cable accurately.) If wrong
connection occurs, output interface of the indicator or that of the printer and even the
indicator and printer may be damaged.
▲! When using printer, connect all lines accurately at first, then switch on the power of
indicator and at last the power of printer. After use, please turn off the printer first
and then turn off the power of indicator and disconnect all the cables. Any reversed
operation may damage the indicator and printer. Please be careful.
▲! Printers are of various model and parameters, they may be not be compatiable with our
indicator. Please choose printers as remmended.
The printer must be equipped with reliable ground. Otherwise, this may disturb
regular performance of the indicator or even damage the indicator and printer.
IV. Connection between Scoreboard and the Indicator and Their Use
▲ ! Output pin of the scoreboard shall be connected accurately without fault. Error connection
may damage the output interface of indicator or that of scoreboard or even damage the
indicator and scoreboard seriously. The connection requires the use of dedicated connection
wires.
1. Interface of the scoreboard is 15-core RS232 connector (use in common with the serial communication
Indicator Interface Pins Sensor (load cell) Interface Pins …… Color of Corresponding Wire
Pin
No.
Definition Connection Method
Zhonghang Electronic
Measuring Indicators
Co., Ltd.
Guangzhou Electrical
Measuring Indicators
Factory
Ningbo Benui Electric
Co., Ltd. /Ningbo
Board Electric Co.,
Ltd.
2 Signal
transmission
negative (-T)
Connect Signal
reception negative
(-R)
Brown White White
4 Signal
transmission
positive (+T)
Connect Signal
reception positive
(+R)
Yellow Green Green
3 Signal reception
negative (-R)
Signal transmission
negative (-T)
White Yellow Light yellow or
brown
5 Signal reception
positive (+R)
Signal transmission
positive (+T)
Blue Blue Blue
6 Positive pole of
power source (+V)
Connect positive pole
of power source (+V)
Red Red Red
9 Negative pole of
power source (-V)
Connect negative pole
of power source (-V)
Black Black Black
1 Shield Connect the shielded
wire
―― ―― ――
Si
g
nal
g
roun
d
Optional

X K 3 1 9 0 –DS3
(4)
interface《sharing with serial communication interface》). See Pins 9 and 10 for definition of its pins in
Figure (2-5).
Signal of scoreboard is current loop or RS232 signal and it is output serially in binary code with
baud rate of 600. Each frame has 11 bits, i.e. one start bit (0), 8 data bits (lower bits in front), one mark
bit and one stop bit (1).
3. The indicator sends out a group of data every 100ms with 3 frames of data contained. See the
meaning in Figure (2-6).
First frame data: the mark bit is 0;
Signal ground
Connect the scoreboard
Scoreboard RS233 output interface
(Figure 2-5) Serial communication and scoreboard output interface signal back scheme of the machine housing
First frame
Bit
Start bit
Mark bit
Stop bit
(Figure 2-6.1) First frame oscillogram
Second frame
Bit
Start bit
Mark bit
Stop bit
(Figure 2-6.2) Second frame oscillogram
Third frame
Bit
Start bit
Mark bit
Stop bit
(Figure 2-6.3) Third frame oscillogram

X K 3 1 9 0 –DS3
(5)
X : D0、D1、D2 – is the position of decimal point ( 0~4 )
Y : D3 — is the symbol of weight ( 1-negative, 0-positive)
D4 — standby
G 18~G16: data of weight (net weight)
Second frame data: the mark bit is 0;
G 15~G8: data of weight (net weight)
Third frame data: the mark bit is 1;
G 7~G0: data of weight (net weight)
G0~G18: constitute the 19 bits binary codes of weight from low to high (net weight)
V. Connection between Serial Communication Interface and the Indicator and Their
Use
▲! Output lead of the communication interface and computer shall be connected accurately. Error
connection may damage the output interface of indicator, communication input interface of computer or
even damage the indicator, computer and corresponding external equipment.
▲! Operation related to computer communication requires necessary computer technology and
capability of programming. Therefore, it shall be participated or guided by professional technician.
Non-professionals are not allowed to connect the indicator.
The indicator XK3190-DS3 is equipped with RS232/RS422 (optional)/RS485(optional) serial
communication interface for communication purpose with computer.
1. Communication interface is equipped with 15 core RS233 connector assembly (shared with scoreboard). See
definition of pins 6, 7, and 8 (RS232) or 1, 2, 3, 4 and 8 (RS422/RS485) in Figure 2-5.
2. All datas are of ASCII code. Every group of data is constitute of 10 bits of data, the first bit is start bit, the 10th
bit is stop bit and the mid eight bits are data bits. Communication methods are divided into:
(1) Continuous mode:
Data being sent is the current weight (gross weight or net weight) displayed on indicator. Data of
each frame is comprised of 12 groups of data. See the forms as follows,
Byte X Content and Note
1 02(XON) Start
2 +or- Signbit
3 Weighingdata Higherbit
:Weighingdata :
:Weighingdata :
8 Weighingdata Lowerbit
9 Decimalpoints Fromrighttoleft(0~4)
10 Xorchecking Fourhigherbits
11 Xorchecking Fourlowerbit
12 03(X0FF) End
Xor =2⊕3⊕……8⊕9
(2). Command mode:
Corresponding data is sent by the indicator by command from host computer. With an command sent
from the host computer, the indicator outputs a frame of corresponding data. Commands sent by host
computer are as follows,
X byte Content and Note
1 02(XON) Start
2 A~Z SerialNo.ofAddress
A~E Command (command)A: Hand shaking
CommandB:Readinggrossweight
CommandC:Readingtare
3
CommandD:Readingnetweight
4 Xorchecking Fourhigherbits

X K 3 1 9 0 –DS3
(6)
X byte Content and Note
5 Xor checking (Fourlowerbits
6 03(X0FF) End
Xor=2⊕3
Contents output by the indicator:
X byte Content and Note
1 02(XON) Start
2 A~Z No.ofAddress
3 A~E CommandA:Handshaking
Command B: Input the gross weight
Command C: Input the tare
Command D: Input the net weight
4 Press command to output corresponding data
: Press command to output corresponding data
n-1 Press command to output corresponding data
n Press command to output corresponding data
n+1 Xorchecking Fourhigherbits
n+2 Xorchecking Fourlowerbits
n+3 03(X0FF) End
Xor=2⊕3⊕……( n-1 )⊕n
Contents of 4~n output by the indicator are as follows,
Command
A No data Each frame is composed of six
groups of data
Command
B
Gross weight, form:
a: Symbol(+or-)
b: Gross weight value ( 6 bits)
: (Fromhighertolower)
g
Each frame is composed of 14
groups of data
h: Decimal point from right to left (0~4)
Command
C
Tare, form:
a: Symbol(+or-)
b: Tarevalue(6bits)
: (Fromhighertolower)
Each frame is composed of 14
groups of data
g
h: Decimal point from right to left (0~4)
Command
D
Net weight, form:
a: Symbol(+or-)
b: Netweightvalue(6bits)
: (Fromhighertolower)
Each frame is composed of 14
groups of data
g
h: Decimal point from right to left (0~4)
Note 1: Xor checking four higher and lower bits’ confirmation: Xor value and four higher and lower
bits are smaller than or equal to 9 will be added with 30h and turned to be ASCII code number for
sending, for example, four higher bits of Xor checking is 6, and this plus 36h is 6 in ASCII for sending
out; Xor, four higher bits and four lower bits which are larger than 9 will be added with 37h and turn to

X K 3 1 9 0 –DS3
(7)
be ASCII code letter for sending, for example, Xor checking four higher bit is B. With 37h added, it is
42h, i.e. letter B in ASCII code for sending out.
3. Command list sent by host computer (set address of the indicator as 01):
Category Content of Command Host computer sends out commands (hexadecimal)
Command A Hand shaking 02 41 41 30 30 03
Command B Reading gross weight 02 41 42 30 33 03
Command C Reading tare 02 41 43 30 32 03
Command D Reading net weight 02 41 44 30 35 03
4. Indicator communication parameter setting:
(1). Communication parameters
Communication parameters are made up of three groups of parameters, i.e. communication address, baud
rate and communication method.
(2) Steps for setting communication parameters:
Step Operation Displayed content Note
1
Press [Parameter
setting]
In the weighing and
displaying state
2
Press [9][8]
Press [Input]
[ P 00 ]
[ P 98 ]
Input the setting password “98”
3
Press [1]
Press [Input]
[ Ad r ** ]
[ Ad r 01]
Address ( 01~26 )
E.g.: 1
4
Press [1]
Press [Input]
[ b t * ]
[ b t 1]
Baud rates of serial communication (0~4)
means following baud rates respectively:
600, 1200, 2400, 4800 and 9600 baud rates.
E.g.:1
5
Press [0]
Press [Input]
[ t F * ]
[ t F 0 ]
Way of serial communication:
0—Continuous send mode, no reception
1—Appointed answering mode
2—Old D2+ continuous communication
format, 8 bits every frame
3—New D2+ continuous communication
format, 9 bits every frame
(See Note 2)
E.g. 0
6 Weighing state Communication parameter setting is
completed
Note 2: In the old D2+ continuous communication format, data is output in form of ASC code with 8Ⅱ
bits in every frame (including the decimal point). Lower bits of the data are sent at first and then
the higher ones. The frames are divided by “=”. Data being sent is the net weight (i.e. the value
displayed on indicator), for example, when the value 70.15 is displayed, the indicator
continuously sends out 51.0700=51.0700=51.0700…….
In the new D2+ (300 tons) continuous communication format, data is output in form of
ASC code with 9 bits in every frame (including the decimal point). Lower bits of the data areⅡ
sent at first and then the higher ones. The frames are divided by “=”. Data being sent is the net
weight (i.e. the value displayed on indicator), for example, when the value 70.15 is displayed,
the indicator continuously sends out 51.07000=51.07000=51.07000…...
Chapter 3 Operation Method

X K 3 1 9 0 –DS3
(8)
I. Startup and Auto Startup Zero Setting
1. Connect the AC power source or external battery and turn on the power to conduct stroke self-check of
“9999999”~ “0000000” and then enter into weighing state automatically after this.
2. During the process of stroke self-check, you may press any key to stop the self-check.
3. After starting up, if weight on the scale is deviated from null point but still within the setting range, the
indicator will conduct zero setting automatically. See detailed parameter selection and setting methods of
startup zero setting in relevant chapter of calibration.
During normal operation, please turn the calibration switch to non-calibration position.
II. Manual Zero Setting (Semi-auto Zero Setting)
1. Press [Zero] to make the indicator setting return to zero. At this moment, null position identifier lights up.
2. When the displayed value is deviated from null point but still within range of zero setting, the key [Zero] will
work; otherwise, it will not work. See detailed parameter selection and setting methods of zero setting in
relevant chapter of calibration.
3. Zero setting may only be conducted when the stable identifier is on.
III. Tare operation
1. There are three tare methods:
(1) Normal tare:
Under weighing displaying state, when weight is positive and stable, press [Tare] to deduct the value
displayed as tare weight. At this moment, the instrument displays the net weight 0 and the tare light is
on.
(2) Preset tare:
Under weighing displaying state, press [Tare] to see [P ***.**] displayed on the indicator. This is the
original tare weight. For setting a new tare weight, please input the value with number keys and press
[Input] for confirmation.
(3) Call tare weight by vehicle no.:
Under weighing displaying state, press [Vehicle No.] to see [o *****] displayed on the indicator.
Please input the correct vehicle no. with number keys and press [Tare]. At this moment, the indicator
may find a tare weight corresponding to the vehicle no. from its memory for use.
Under weighing displaying state, continuous tare operation may be conducted. When tare weight is 0, the tare
light is off; when the indicator meets the requirement of zero setting, press [Zero] to set the tare weight to zero.
At this moment, the tare light is off.
IV. Set Date and Time
Under weighing state, press [Clock] to see current date on the indicator. Enter the
correct date and press [Input] for confirmation. The indicator then displays current time
and runs automatically. At this moment, input the correct time and press [Input] for confirmation to
complete date and time setting.
V. Use of Battery
1. When using battery for power supply, it displays “Battery capacity” on the left side of display
window for indicating the remaining electricity; when three indicating lights are all on, there is
sufficient electricity; when the lower two identifiers are on, there is still comparatively sufficient
electricity and when only the bottom one is on, it indicates the electricity is low. When the
electricity is not sufficient, please charge the battery. Further use may decrease the battery
capacity till the instrument automatically power off for protecting the battery.
2. After connecting the battery to the indicator and switching on the AC power, the indicator may
charge the battery (full charge needs about 20 hours). Whether the power switch is turned on or
off, the battery will be charged. However, it is recommended to charge .
3. The first time the battery is used, make sure it is fully charged.
4. On the connecting line of battery, the plug marked with red color is the positive pole (+) and it
shall be connected with the positive pole of battery and the one marked with black color is the
negative pole (-) and it shall be connected with the negative pole of battery.
5. For protecting the indicator and battery, both wrong connection of the battery’s positive and
negative poles or short-circuit may cause circuit broken of DC resettable fuse to protect the
indicator and battery. Then, please connect the battery properly and restart the indicaotr for
regular service.
6. As batteries are consumables, they are not in warranty scope.

X K 3 1 9 0 –DS3
(9)
VI. Internal Code Display
1. Under weighing state, press [Set] and input [2] and [8] to enter the inner code displaying
state with inner code indicating light on; then re-press [Set] and input [2] and [8] to quit the
inner code displaying state with inner code indicating light off.
2. Under inner code displaying state, keys except [Zero] and [Set] are invalid.
3. 20 internal codes are equal to a division value. For example, a scale with its n=3000, the
full capicity inner code is 60000.
VII. Save Data Record
1. Vehicle no. of the indicator is 5-bit number and article no. is 3-bit number. 1000 vehicle
numbers and 201 article numbers can be saved.
2. The record of a group of data will be printed out at after a complete set of data is saved
(relevant printing setting shall be valid).
3. Three methods of data storage:
1) Save weight for empty vehicle at first and then for full vehicle or save weight for full vehicle at first and
then for empty vehicle, i.e. a complete record is composed of two times’ data saving.
2) For weighing full vehicle with known tare weight, one time of data saving may form a complete record.
3) For weighing just article, one time of data saving may form a complete record.
For recognizing and classifying three above situations, we make following agreement for
XK3190-DS3:
▲ The vehicle no. shall be a number within the range of 00001~99999, i.e. 00000 cannot be kept as
a real vehicle number. When being set as 00000, it means that the object being weighed is not a
vehicle with article but only a article.
▲ When [Tare] light is on, the tare is known and therefore one time data saving may constitute a
complete record.
▲ When vehicle no. is an any 5-bit number other than 00000, the highest bit of parameter Y in the
printing parameters is set as 0 and the tare light of indicator is not on, two times’ saving may
constitute a complete record.
4. Saving Method:
(Table3-1)
Step Operation Displayed content Note
1
Press [Print]
Under weighing displaying
state
2
Input the vehicle no. by pressing number
keys
Press [Input]
[ o *****]
[ o 03217]
Input the vehicle no.
E.g.: 03217
3
Input the article no.
Press [Input]
[hn **]
[hn 35]
Input the article no.
E.g.: 35
4
Press [10]
Press [Input]
[BFL **]
[BFL 10]
Input the percentage of discount
rate
E.g.: 10
Complete saving
Data saving of indicator may adopt the way of vehicle number. or not. See detailed information in the
chapter printing settings. If setting as not using vehicle number, there will be no operations, steps or
printing contents about vehicle number. Similarly, data saving of indicator may adopt the way of
article number or not. See details in the chapter about printing settings.
▲ ! When data is unstable or when gross weight ≤0 or net weight≤0, data cannot be
saved.
5. About automatic save and printing:
1) See setting about automatic save and printing in the chapter about printing settings.
2) Automatic save and printing have no operation method of two times’ saving.
3) The vehicle number and article number saved during the process of automatic saving are the vehicle number and
article number set before saving.
4) Tare weight during the process of automatic saving has following three detailed occasions,
(1) When tare light is on, the current tare weight will be recorded in the group of data.
(2) When tare light isn’t bright, the indicator will automatically search for tare weight of the vehicle from its
memory and save this tare weight in current group of record.
(3) When tare light isn’t bright and there is no tare weight of the vehicle saved in memory, 0 will be judged

X K 3 1 9 0 –DS3
(10)
as the tare weight and saved in the group of record.
6. When vehicle numbers are more than 1000, [Err 10] will be displayed on the indicator. A vehicle
number or all contents recorded may be deleted in the way introduced in Chapter 11.
VIII. Operation of Printing
1. Printing settings (Table 3-2)
Step Operation Displayed content Note
1
Press [Set]
Press [9] [7]
Press [Input]
[ P 00]
[ P 97]
Input the password 97
2
Press [1]
Press [Input]
[Auto *]
[Auto 1]
Select auto/manual printing
(0-Manual 1-Auto)
E.g.: Select 1 (Automatic printing)
3
Press [3]
Press [Input]
Auto identifier lights up
[Type *]
[Type 3]
Select type of printer
0--Invalid printing
1--TPup16 micro-printer (English)
2--TM800 printer
3—Panasonic KX-P1121
4--EPSON LQ-1600K, LQ300K+,
Panasonic KX-P1131
5--Reserved
6—External thermal micro-printer POS58 and
T58D etc.
E.g.: Select 3
4
Press [5] [0]
Press [Input]
[ HL **]
[ HL 50]
Print only when:
00-Back to zero
25-Back to <25% F.S.
50- Back to <50% F.S.
75- Back to <75% F.S.
99- Even it’s F.S.
for example: 50
5
Press [3]
Press [Input]
[Arr *]
[Arr 3]
Select print form
Arr=
0: record format
1: 1-page linked format
2: 2-page linked format
3: 3-page linked format
for example: 3
6
Press [1] [0] [0]
Press [Input]
[L *****]
[L001.00]
Set min. weight for auto
print function
It must be lager than 10d
for example: 1.00
7 Press[0][5]
Press [Input]
[b **]
[b 05]
Rows for printer(0~30)
for example: 05
8
Press [1]
Press [Input]
[odE *]
[odE 0]
Select filled-in print:
0-Not select
1-Select
for example: 0
9
Press [1]
Press [Input]
[dct *]
[dct 0]
Select discount rate at
filled-in print form:
0-Not use discount rate
1-Use discount rate
for example: 0
10 Press [0] [0] [0][1][1]
Press [Input]
[Y *****]
[Y 00011]
Parameter Y has 5 digits, they are respectively
1st~5th digit from left to right. Their functions
are as follows,
1st digit: 0 twice weighing and printing
mode;
1 once weighing and printing
mode;
2nd digit: 0 Do not use the function of
power saving;
1 Use the function of power
saving;

X K 3 1 9 0 –DS3
(11)
Step Operation Displayed content Note
3rd digit: 0 Unit of weight is kilogram
1 Unitofweightiston;
4th digit: 0 Do not use article number in
data record
1 Usearticlenumberindata
record;
5th digit: 0 Do not use vehicle number in
data record
1 Use vehicle number in data
record;
E.g.: Select 00011
End of operation
Note: (1) When using an external printer, types of printers are 1, 2, 3, 4 and 6 according to different
style of printers.
(2) Steps 8 and 9 are only applicable to printers of type 2 and 3 Instead of others.
▲! Discount rate will be selected only when the print format is filled-in.
★ See detailed printing forms in appendix.
★ Special format carbon-free duplicating and typing paper can be used for Filled type printing
for quick print in triplicate. Special format normal typing paper may also be used for quick
print in one copy.
★ For commanding filled type printing of special format, please contact the distributor.
2. Data saving and printing of the indicator are conducted at the same time. Press [Print], you may
print the weighing record while a complete group of record is saved (setting of printing have to be
valid).
3. For printing failure of weighing record caused by some reasons (for example, printer fault),
current record may be printed by press [Suppl Print] after relevant fault is removed.
4. After weighing, you may press [Accumulated Printing] to print the accumulated recording amount
of this group.
5. When twice weighing and printing mode is set in the indicator, with the twice saving method of
empty vehicle at first and then heavy one or heavy vehicle at first and then empty one, as the
record is still not complete during the first time of saving, [LoAd] will be displayed on the
indicator for about 1.5 seconds for reminding the operator. However, printing will not be
conducted now. At this moment, you may press [Suppl Printing] to print the incomplete record
out.
Results of printing will always be: 1,Serial no.:blank;
2,Gross W, net W:0
3,Tare W: Current display
(See information about setting of twice weighing and printing mode in contents about parameter Y in
printing setting)
6. When once weighing and printing mode is set in the indicator, data for each time of weighing will
be saved and printed as a complete record. Under tare state, the indicator will regard current tare
weight as the one to be recorded. If not, the indicator will call the corresponding memorized tare
weight saved in indicator and regard the value as tare weight to be recorded (tare weight will be
recorded as 0 if there is no memorized tare weight). See information about setting of once
weighing and printing mode in contents about parameter Y in printing setting.
IX. Report Printing
1. Press [Report], input the date and press [Input] to print daily report on the basis of classified
statistics (i.e. statistical form made according to time sequence, vehicle number and article
number).
2. Press [Report] and [1] to print summary report 1 (i.e. statistical form made according to time
sequence)
3. Press [Report] and [2] to print summary report 2 (i.e. statistical form made according to vehicle
number)
4. Press [Report] and [3] to print summary report 3 (i.e. statistical form made according to article
number)
5. Press [Report] and [4] to print summary report 4 (i.e. tare report made according to vehicle
number)

X K 3 1 9 0 –DS3
(12)
X. Inquiry Record
All kinds of recorded contents in the indicator can be checked by using the key [Check] in
differentways.Seedetailedoperationwaysasfollows,
1. Check weighing record according to date (Table 4-4)
Step Operation Displayed content Note
1
Press [Check]
Press [Check]
Under weighing
state
[rEAd 1]
Select the content and format to be checked
rEAd=1-- Check all record of a day
2--Check all record of a vehicle number
3-- Check all record of a article number
4—Check vehicle number
2
Input the date
Press [Check]
[d **.**.**]
[d 08.08.25]
Select the date you want to check:
E.g.: August 25
Each time of record of August 25th, 2008 will then be
displayed in sequence.
3
Press [Check]
Press [Check]
Press [Check]
Press [Check]
Press [Check]
Press [Check]
Press [Check]
[no 0001]
[t**.**.**]
[o *****]
[hn ***]
[A *****]
[t *****]
[n *****]
Firsttime
Time (Hour/Minute)
VehicleNo.
ArticleNo. Recordofthefirsttime
GrossWeight
Tare
NetWeight
4
Press [Check]
Press [Check]
Press [Check]
Press [Check]
Press [Check]
Press [Check]
Press [Check]
[no 0002]
[t**.**.**]
[o *****]
[hn ***]
[A *****]
[t *****]
[n *****]
Second time
Time (Hour/Minute)
VehicleNo.
Article No. Record of the second time
GrossWeight
Tare
Net Weight
… … …
Press [Check]
[ End ] End
Return to weighing
and displaying state
(1) At Step 2, you may delete all weighing record of the date by pressing [Zero Setting]. (Reset
mode )④
(2) In Step 3 and after that, you may delete the group of weighing record you are checking by
pressing [Zero]. (Reset mode )⑦
(3) After entering in the state of checking, [Check] and [Input] keys have same functions.
2. Check weighing record according to vehicle number (Table 4-5)
Step Operation Displayed content Note
1
Press [Check]
Press [2]
In weighing state
[rEAd 1]
[rEAd 2]
Select 2 means check record according to vehicle number
2 Press [Check]
Input the vehicle
number
[o *****]
[o 12345]
Select the vehicle number for checking
E.g.: 12345
Then, all weighing record of vehicle 12345 will be
displayed.
3 Press [Check]
Press [Check]
Press [Check]
Press [Check]
Press [Check]
Press [Check]
Press [Check]
[no 0001]
[d**.**.**]
[t**.**.**]
[hn ***]
[A *****]
[t *****]
[n *****]
Date (Month/Date)
Time (Hour/Minute)
ArticleNo. Recordofthefirsttime
GrossWeight
Tare
NetWeight
4 Press [Check]
Press [Check]
[no 0002]
[d**.**.**]
Date (Month/Date)

X K 3 1 9 0 –DS3
(13)
Step Operation Displayed content Note
Press [Check]
Press [Check]
Press [Check]
Press [Check]
Press [Check]
[t**.**.**]
[hn ***]
[A *****]
[t *****]
[n *****]
Time (Hour/Minute)
Article No. Record of the second time
GrossWeight
Tare
Net Weight
… … …
[ End ] End
(1) At Step 2, you may delete all record of the vehicle number but maintain its memorial tare
weight by pressing [Zero]. (Reset mode ⑤)
(2) At Step 4 and after that, you may delete the group of weighing record you are checking by
pressing [Zero Setting]. (Reset mode )⑦
(3) After entering in the state of checking, [Check] and [Input] keys have same functions.
3. Check weighing record according to article number (Table 4-6)
Step Operation Displayed
content
Note
1 Press [Check]
Press [3]
Press [Check]
In weighing
state,
[rEAd 1]
[EAd 3]
Select 3 means checking record according to
article number
2 Input the
article no.
Press [Check]
[hn **]
[hn 23]
Select the article number for record checking, e.g.:23;
Then all weighing record of article with serial
number 23 will be displayed.
3 Press [Check]
Press [Check]
Press [Check]
Press [Check]
Press [Check]
Press [Check]
[no 0001]
[o *****]
[d**.**.**]
[t**.**.**]
[A *****]
[t *****]
Vehicle Number
Date (Month/Date)
Time (Hour/Minute) Record of the first time
GrossWeight
Tare
4 Press [Check]
Press [Check]
Press [Check]
Press [Check]
Press [Check]
Press [Check]
[no 0002]
[o *****]
[d**.**.**]
[t**.**.**]
[A *****]
[t *****]
Vehicle Number
Date (Month/Date)
Time (Hour/Minute) Record of the second time
GrossWeight
Tare
… … …
[ End ] End
(1) In Step 2, you may delete all record of the article number by pressing [Zero]. (Reset mode
⑥)
(2) In Step 3 and after that, you may delete the group of weighing record you are checking by
pressing [Zero]. (Reset mode )⑦
(3) After entering in the state of checking, [Check] and [Input] keys have same functions.
4. Vehicle no. checking (Table 4-7)
Step Operation Displayed content Note
1
Press [Check]
Press [4]
Press [Check]
In weighing state
[rEAd 1]
[rEAd 4]
Selecting 4 means vehicle
number checking
2
Press [Check]
Press [Check]
[no 001]
[o *****]
The first vehicle no.
3 [no 002]

X K 3 1 9 0 –DS3
(14)
Press [Check]
Press [Check]
[o *****]
The second vehicle no.
… … …
n
Press [Check]
Press [Check]
[no nnn]
[o *****]
The last vehicle no.
Press [Check]
[ End ]
Return to weighing
displaying state
(1) During the process of above operation, when the vehicle number is displayed, you may delete the
vehicle number, its memorial tare and all weighing record of the vehicle number by pressing
[Zero]. (Reset mode ②)
(2) After entering in the state of checking, [Check] and [Input] keys have same functions.
XI. Operation of Clearing Record
1. The indicator has following record clearing modes:
Mode : Clear all record (inlcuding all vehicle numbers and①memorized tare weight)
Mode : Clear a vehicle number,②memorized weight and all the corresponding weighing records of
the vehicle number;
Mode :Cleartheweighingrecord③saved at last time;
Mode :Clearallrecord④s of a certain date;
Mode : Clear all the corresponding weighing record⑤s of a vehicle number (but reserve the vehicle
number and its memorized tare)
Mode :⑥Clear all the corresponding weighing records of a vehicle number;
Mode :⑦Clear a random weighing record in the instrument.
2. Using any record clearing mode, [] will be displayed on the indicator for operator’s confirmation. When
[Sure]= a non-zero number, press [Input] for confirmation. For negation, set [Sure]=0 and press [Input] or
[Weighing] to quit.
3. Operation method:
1) Under weighing state, press [Clear] to clear all records. [Mode ①]
2) Under weighing state, press the key [Vehicle No.], input the vehicle number with number keys and
press [Clear] to clear the vehicle number, its corresponding memorized tare weight and record.
[Mode ②]
3) Under weighing state, press [Clear], [9] and then [Input] to clear the record saved at last time. [Mode
③]
4) See clearing modes , , and in the chapter of data record and check.④⑤⑥ ⑦
▲! The 1000 groups of records contain the records cleared by modes ②, ③, ⑤, ⑥and ,⑦i.e.
clear records by pressing ②, ③, ⑤, ⑥and ⑦may cause the decreasing of max capacity of
record quantity. Clearing by mode ①, the max capacity of record quantity will be recovered to
1000 groups. If not clearing records by mode ①all the while, decreased records will be recovered
gradually.
▲! Cleared data is nonrecoverable. So please be careful to avoid incorrect operation and
data loss.
▲! All weighing records shall be cleared after calibration or printing parameter
modification.

X K 3 1 9 0 –DS3
(15)
XII. Input Method of Saving Tare weight
The indicator can save 1000 tare weight for a long time. Three input modes are as follows,
1. Input tare with number keys: (* is the original setting value) (Table 3-8)
Step Operation Displayedcontent Note
1
Press [Vehicle
No.]
Under weighing and
displaying state
2
Input the
vehicle no.
Press [Input]
[o *****]
[o 35790]
Input the vehicle number, e.g.: 35790
3
Input the tare
Press [Input]
[P *****]
[P 01000]
Input the tare, e.g.: 1000(kg)
4 Return to weighing and
displaying state
End
2. Tare saving by weighing
Under tare displaying state, load an empty vehicle on the weighing platform, wait until the scale is
stable, press [Tare Storing], input the vehicle number and press [Input].
3. For saving a group of weighing record, if there is no memorized tare weight of the vehicle number
in memory of the indicator, the tare value of this group recorded will be regarded as memorized tare
of the vehicle and saved in memory.
XIII. Power Saving Function
When the function of power saving is set as valid, the indicator will automatically come into
power saving state after at null position (before tare) for 30 seconds (LED display is off and state
indicating sign maintain). At this moment, it will be back to normal display state by pressing any key
or getting out of the null position state.
See information about setting of power saving in contents about parameter Y in print setting)
XIV. Adjustment of Brightness
XK3190-DS3 has 6 levels of brightness for adjustment.
Press [Brightness] once to adjust the brightness to a higher level. When the brightness is adjusted
to the highest level, the buzzer will send out a long alarm sound to remind the operator. At highest
brightness level, the brightness will be darkest by pressing [Brightness] again. Repeat this procedure
for proper brightness.
XV. Switch between Gross Weight and Net Weight
Under weighing state, when there is tare weight(net weight displaying state), the indicator may be
switched to gross weight displaying state by pressing [Gross/Net Weight] and then switched back to
the original net weight displaying state by pressing [Gross/Net Weight] again.
After tare or preset tare weight, the indicator enters into net weight displaying state automatically.
When there is no tare weight, the indicator will stay under gross weight displaying state and the
key [Gross/Net Weight] will be invalid.

X K 3 1 9 0 –DS3
(16)
Chapter Four Maintenance and Attentions
1. To ensure clarity of display and service life of indicator, the indicator should be used off direct
sunlight and should be kept at flat place.
2. Do not use the indicator in place of much dust, serious vibration or humidity .
3. Connection between load cell and indicator shall be reliable and the system should have valid
grounding. Keep them away from high electric and high magnetic fields. Load cell and indicator
shall be kept away from highly corrosive object and inflammable and explosive materials.
▲ ! Do not use in occasion with inflammable gas or stream or system with pressure vessel tank.
▲ ! Do not use in area with high frequency of thunder. Reliable lightning protectors shall be
installed for ensuring personnel security of operators and preventing damage of indicator and
relevant equipment caused by thunder.
▲ ! As load cell and indicator are both static-sensitive equipment, feasible anti-static precautions
must be taken during the process of use. Welding operation or other high electric field
operations are strictly prohibited on weighing platform; in the season of thunder storm,
reliable lightning protection measures must be taken for preventing load cell and indicator
from damage caused by thunder and ensuring personnel security and safe operation of
weighing equipment and relevant equipment.
4. Do not use strong solvent (e.g. benzene or nitro oil) for cleaning the machine housing.
5. Do not inject fluid or other conductive particle into the indicator so as to prevent damage of
instrument and electric shock.
6. Before plugging or unplugging connecting wire between indicator and external equipment, please
cut off the electricity supply of indicator and relevant equipment.
▲ ! Before plugging or unplugging connecting wire of load cell, please cut off the power
supply of indicator at first.
▲ ! Before plugging or unplugging connecting wire of printer, please cut off the power
supply of printer and indicator at first.
▲ ! Before plugging or unplugging connecting wire of scoreboard, please cut off the power
supply of scoreboard and indicator at first.
▲ ! Before plugging or unplugging connecting wire for communication, please cut off the
power supply of indicator and host computer at first.
7. The Company advises our customers to check and accept before using instrument products
of the Company. We are only responsible to quality of the indicator itself. The highest
compensation amount is within double value of the fault indicator. We assume no
responsibility for system problem of the indicator.
8. External interfaces of the indicator shall be used according to methods defined in the operation
commands. No unauthorized modification to the connection is allowed. In case of any failure,
please unplug the plug and send the indicator to professional manufacturer for maintenance.
Unprofessional weighing apparatus manufacturers are not allowed to fix the indicator by
themselves in command to avoid greater damage. The indicator shall not be opened at random.
Otherwise, we will provide no warranty service.
9. Batteries are consumables and they are not in warranty scope.
▲! For extending service life of battery, please use it after full charge.
For long time unused, please charge the battery once every two months for 20 hours each time.
▲! Handle with care during transportation and installation. Avoid strong vibration, strike or impact in
command to avoid short circuit inside the batteries and damage of batteries.
10. Within 1 year since the indicator is sold, under normal use conditions, damages not caused by
man-made fault belong to the warranty scope. Please mail the product and warranty card (with
matched ID) to authorized maintenance point or the supplier. The manufacturer provides life-long
maintenance service for the indicator.

X K 3 1 9 0 –DS3
(17)
Chapter Five Information Cue
I. Regular information cue:
1. means:Please wait, the indicator is conducting internal calculation. Do not carry
out any operation now.
2. Prnt means: Please wait; data is transmitted between the indicator and printer.
3. LoAd means: Data save. It will be displayed for less than two seconds for giving a cue
to the operator.
II. Error operation information cue:
1. Err 03 means: overload alarm, all or part of the load must be unloaded at once.
2. Err 08 means: No matched record is found or inquiry condition is wrong.
3. Err 10 means: Vehicle numbers saved are more than 1000.
4. Err 17 means: Parameter setting does not meet the requirement, please reset it.
5. Err 19 means: Printing cannot be conducted in occasion of zero or negative weighing,
unstable weighing or unfulfilled zero reset condition.
6. Err 28 means: When the print date is earlier than that saved in weighing record, please
reset date and clear all record.
III. Error connection information cue:
1. Err P means: Error printer connection or printer fault. Press any key to exit and
re-connect the printer or replace it with another one.
2. Erd ** means: The digital load cell with address “**” has communication failures.
(1) If this is a scale in use, we may judge whether there is a connection failure or the
communication interface of load cell is damaged.
(2) If this is the scale is not debugging, you can check according to the following command
a. Check carefully if the connection wire of load cell is connected properly.
b. Check if address of load cell is right without replication.
c. Please re-set the quantity of load cells.
IV. Information cue of components and parts failure and elimination methods
1. Err 18 means: The keyboard fails. This will be displayed for 10 seconds before entering
into weighing displaying page. The keyboard shall be replaced.
2. Err 20 means: a part of the data in RAM has been lost. Plug the calibration socket into
the indicator and restart it for self-check. After this, without finding the
occurrence of Err 20, the calibration socket may be unplugged.
3. Err21 means:RAMandE
2PROM calibration data are data lost. Please plug the
calibration socket, re-enter the original calibration data and restart the indicator
or conduct calibration again.
4. Err 22 means: RAM destroyed; please replace it with a new chip and then conduct
calibration again.
5. Err23 means:E
2PROM destroyed; please replace it, re-enter the original calibration

X K 3 1 9 0 –DS3
(18)
data and then restart the indicator or conduct calibration again.
6. Err 25 means: illegally duplicated software or E2PROM. destroyed
Appendix 1: (applicable to printers of TYPE=2, 3 and 4)
Bills in a set:
WeighingSheet WeighingSheet WeighingSheet
No. 0001 No. 0001 No. 0001
Date 1999-07- Date 1999-07-28 Date 1999-07-28
Time 12.02.31 Time 12.02.31 Time 12.02.31
Vehicle No. 12345 Vehicle No. 12345 Vehicle No. 12345
Article No. 022 Article No. 022 Article No. 022
Gross Wei
g
ht 2.000
(
k
g)
Gross Wei
g
ht 2.000
(
k
g)
Gross Wei
g
ht 2.000
(
k
g
)
Tare Wei
g
ht 0.300
(
k
g)
Tare Wei
g
ht 0.300
(
k
g)
Tare Wei
g
ht 0.300
(
k
g)
Net Wei
g
ht 1.700
(
k
g)
Net Wei
g
ht 1.700
(
k
g)
Net Wei
g
ht 1.700
(
k
g)
Recording format:
Weighing Sheet Date: July 28, 1999
No. Time Vehicle No. Article No. Gross Wei
g
ht
(
k
g)
Tare
(
k
g)
Net Wei
g
ht
(
k
g)
0002 12.03.24 12345 033 2.000 0.300 1.700
0003 12.03.24 00888 033 2.000 0.300 1.700
0004 12.04.11 00888 022 2.000 0.300 1.700
Accumulated amount: Gross weight: 8.000(kg) Net weight: 6.800(kg)
Filled type: (the printing procedure will take only 5 seconds)
WEIGHT BILL
Fo
r
O
p
erator
SERIAL No. 123
DATE 1999-07-28
TIME 12 .35 .28
VEHICLE No.
ARTICLE No.
GROSS 1580
TARE 80
DISCOUNT RATE 10
NET 1350
REMAR
K
Appendix 2: (applicable to printers of TYPE=2, 3 and 4)
Daily Sheet 1 Date: July 28, 1999
No. Time Vehicle No. Article No. Gross Weight (kg) Tare (kg) Net Weight (kg)
0002 12.03.24 12345 033 2.000 0.300 1.700
0003 12.03.24 00888 033 2.000 0.300 1.700
0004 12.04.11 00888 022 2.000 0.300 1.700
Accumulated amount: Gross weight: 8.000(kg) Net weight: 6.800(kg)
Daily Sheet 2 Date: July 28, 1999
No. Vehicle No.
Vehicle Weight
(kg)
Times Gross Weight (kg) Total Net Weight
(kg)
0001 12345 0.300 0002 4.000 3.400
0002 00888 0.300 0002 4.000 3.400
Table of contents