Process Sensors METIS M311 Instruction manual

Pyrometers
METIS M311 / M322
METIS H311 / H322
With12-pinconnector,displayandpushbuttondeviceconguration
Optics:
■Fiberoptics
■Manualfocusableoptics
■Motorizedfocusoptics
Sightings:
■Through-lensviewnder
■Laser targeting light
■Camera module
The detailed operation manual can be found on the CD and under www.sensortherm.de/en/download-section.
There also the current device rmware and the software SensorTools can be downloaded.
General Information
■Readthismanualandthecompleteusermanualcarefullybeforeoperatingtheproduct.Allsecuritynotesandoperationproce-
duresinthemanualsmustbefollowedtoensuresafety.
■Theproductconformstothefollowingstandards:CEconformity:DINEN61326-1(electromagneticcompatibility),lasersafety:
IEC60825-1(laserclass2),RoHS:2011/65/EU.
■ProcessSensorsisnotresponsiblefordamagecausedbyfailuretoobserveinstructionsinthismanual,deviationfromintend-
eduse,assignmentofunskilledpersonnel,unauthorizedmodications,technicalmodicationsortheuseofunapprovedspare
parts.
■FordeviceswithintegratedPIDcontrollerProcessSensorsCorporationassumesnoguaranteethatthetemperaturecontrolinall
processesmeetthedesiredrequirements.ProcessSensorsexcludestheprocessofresponsibility.
Safety
■When connecting or when working on the mains voltage,generalsafetyguidelinesmustbeobserved,e.g.whenconnecting
powertransformers.Mainsvoltagecancauseseriousinjury.Improperinstallationcancausephysicaldamage.Onlyqualied
personnel are allowed to work with mains voltage.
■Foreasyalignment,thepyrometersmaybeequippedwithalaser targeting light, Laser Class 2 (according to IEC 60825-1-3-
4).Thelaseremitsavisibleredlightwithamaximumpowerof<1mWandawavelengtharound650nm.Deviceswithlaser
targeting light are marked with a yellow “CAUTION” sticker.
Safety precautions: Do not look into the laser beam directly. Do not point the laser to anyone. Also ensure the beam will not be
reectedintoeyesofpeoplebymirrorsorshinysurfaces.
■Ifthedeviceisusedinthecommercial sector theoperatorissubjecttothelegalresponsibilitiesforworkplacesafety.
Inadditiontothesafetyinstructionsinthismanualfollowtheregulationsofsafety,accidentpreventionandenvironmentalprotec-
tion.
Intended Use
The2-colorpyrometersoftheMetisM3andH3seriesaredevicesfornon-contacttemperaturemeasurement.TheM3models
havearesponsetimeof<1ms.TheH3modelsarehigh-speedinstrumentswitharesponsetimeof<80µm.
QuickStartManual
1 Electrical Connection
2 Overview
Theunitisreadyforoperationwhenconnectionismade
to the voltage supply. Interrupt the power supply to turn
o󰀨thepyrometer.Topreventaccidentalshortcircuits,
cable wires not in use should be secured to the supplied
screw terminals.
Cable color No. Function
White 1 + 24 V DC power supply (18–30 V DC, power
consumptionM3:max.6VA,H3:max.12VA)
Brown 2 0 V DC power supply (ground)
LEDs 1,2,3 (Active digital outputs)
■Green: Indicates an activated
digital output
Sighting:Through-lensviewnder,lasertargetingbuttonor
connectorforcolorvideo
LED 4 (Operating status LED)
■Orange:Self-testphase
■Green: Ready to operate
■Red: Error
Display
■2C: Ratio temperature (2-color) measuring mode
■C1 / C2: 1-color temp. measuring mode channel 1 or 2
■– – – –: Measuring temperature below zero scale temp.
■OVER: Measuringtemperatureabovefullscaletemp.
DISPLAY> Temperature on display
DISPTMP:2C Ratio (2-color) temperature
DISPTMP: C1 Temperature channel 1 (longer spectral range)
DISPTMP: C2 Temperature channel 2 (shorter spectral range)
MEASPARA> Measurement parameters
T90 Response time t90 (min–10 s)
STMOD Storagemodepeakpicker:OFF,trigger(TRIG),
automatic (AUTO), extern (EXT),
time clear (TIME)
CLR Cleartimesettingsofstoragemode
(onlyifSTMODEsettoTIME):
timesfortimeclearing:1ms–25s
SLO Emissivity slope (0.800–1.200)
SW.OFF Switch-o󰀨limit(2–90%)
Ԑ1 Emissivity(epsilon)channel1(5–120%)
TR1 Transmittancechannel1(5–100%)
Ԑ2 Emissivity(epsilon)channel2(5–120%)
TR2 Transmittancechannel2(5–100%)
FF Fillfactorofspotsize(5–100%)
ZSC Zero scale temperature
FSC Fullscaletemperature
TU Temperateunit°C/°F
OUTPUTS> Outputs
ANALOG> Analog outputs
A1 Analog current output 1 (0/4–20 mA)
A1TST Test current analog output 1
(OFF,10mAat0–20mA,12mAat4–20mA)
A2 Analog current output 2 (0/4–20 mA)
A2OUT Signalanalogoutput2:o󰀨(OFF),2-colortem-
perature (2C), temperature channel 1 (C1) or
channel 2 (C2), control output (CTR; only devices
with PID controller), device temperature (DTMP)
A2TST Test current analog output 2
(OFF,10mAat0–20mA,12mAat4–20mA)
INTERFACE> Serialinterface
RSTYPE InterfacetypeRS232/RS485(onlyM3)
BD Baud rate
RS232: 4.8–115.2 kBd, RS485: 4.8–921.6 kBd
ADD Address (00–97)
DELAY Interfacedelay(00–20)
MISC> Miscellaneous settings
LG Language (English / Deutsch)
N.PIN Set(new)pinforpushbuttonlock
(OFF=nopinrequest)
FACT.SET Resetthedevicetothefactorysetting(no/yes)
5 Adjusting the Measuring Distance / Focus Distance
Inthefocuspointofthelens(focusdistance)thespotsizediameterissmallest,outsidethefocuseddistancethespotsizediameter
isusuallybigger.Precisespotsizescanbefoundinthecompleteoperatingmanualunder“SpotSizeTables”.
■The laser targeting light has its smallest and sharpest picture at the point where the spot size is the smallest.
■ View nder and Camera Module:Themeasuringdistanceisfoundwhentheobjectisinfocus.
4 Factory Settings
■Analog output 1:4–20mA,signalofthemeasuredtempera-
ture (always that temperature, displayed on the device)
■Analog output 2: no temperature output
■Serial interface: RS485, baud rate: 115.2 kBd
■Emissivity slopeԐ2/Ԑ1=1,emissivity Ԑ=1(100%)
■Response time t90=min(correspondsM3:<1ms;H3:<80µs)
■Digital inputs / outputs
- 1:Settoinput:switchingon/o󰀨lasertargetinglight
(deviceswithviewnderorcamera:nofunction)
- 2:Settoinput:clearingofpeakpickerstorage
- 3:Settoinput:nofunction
Press the button repeatedly to get
access to all settings sequentially
(subcategory with >)
Foradjustmentofthepossible
parameters in the categories
Opens a parameter category or takes
overamodiedparametervalue
4 Parameters(adjustmentbuttonsforpyrometerconguration)
Manual Focusable Optics Fiber Optics Motorized Focus
1. Release
2. Adjust
3. Lock (hand-
screwed)
1.
1.
2.
2.
3. 3.
1.
2.
3.
Hexagonsocket1.5mm
Astickerontheopticsshowsthemeasurement/focusdistance(“a”fromfrontofthelens)
10 SensorTools Software (min. Windows 7)
All pyrometer settings can
beadjustedviasoftware
when a PC connection is
established via the serial
interfaceport(forexam-
ple,viaanUSBinterface
converter).
Functionssuchasthe
congurationoftheinputs/
outputs can only be carried
outviasoftware.
In addition, the mea-
surement value trend is
displayed numerically and
graphically and can be
recorded.
With connected pyrometer
the device keys are locked,
when pressing a key “KEY
LOCK” appears.
7 Connecting Analog Devices
The pyrometer has 2 separate analog outputsforconnecting
additional evaluation devices:
■Adjustable to 0-20 mA or 4-20 mA
■Analog output 1 always provides the measured temperature
■To analog output 2 can be assigned the 2-color tempera-
ture, the 1-channel temperature, the device temperature or
thecontrolvaluefordevicesequippedwithaPIDcontroller
Cable color No. Function
Green 3 + Analog output 1 (0 / 4–20 mA)
Yellow 4 - Analog output 1 (0 / 4–20 mA)
White-green 14 + Analog output 2 (0 / 4–20 mA)
Brown-green 15 - Analog output 2 (0 / 4–20 mA)
8 Congure Inputs / Outputs
3viasoftwareSensorTools congurableinputs/outputsare
each available as:
■Digital output:outputofaswitchingsignal(50mA)atdi󰀨er-
ent temperature events.
■Digital input:switchdevicefunctionsexternallyviaaninput
voltage pulse.
■Analog input (only M3): adjust via external 0–20 mA the emissivity slope, emissivity (at 1-channel measurements), the setpoint
(whenequippedwithaPIDcontroller)orthemeasuringdistance(atmotorizedfocusoptics).
Cable color No. Function
Grey 5 Digital input / output 1 1)
Pink 6 Digital input / output 2 1)
Blue 13 Digital input / output 3 / Analog input 1)
1)Referencepotential0V,brown
9 UseoftheSerial Interface
Theserialinterfaceisusedfordigitalcommunicationwitha
computer,forexampleviatheincludedsoftwareSensorTools.
■RS232:Baudrate4.8–115.2kBdforashortdirectconnection
up to max. 20 m.
■RS485:Baudrate4.8–921.6kBdfordirectconnectionorbus
operation with up to 32 devices.
The pyrometer can be connected to a PC with USB port via a
USB interface converter (recommended accessory).
Cable color No. Function
Black 9 RS232: RxD; RS485: B (+) 2)
Grey-pink 11
Violet 10 RS232: TxD; RS485: A (-) 2)
Red-blue 12
Red 8 DGND(groundforinterface)
2)H3modelsonlyRS485
6 Important Measuring Parameters
■ Emissivity slope Ԑ2/Ԑ1or emissivity Ԑ:Foracorrectmeasurementresult,thesurfacecharacteristicsandtheemissivityof
the material to be measured must be considered. In 2-color temperature measurement mode this is the emissivity slope, in
one-channelmodethisistheemissivity(anemissivitytablecanbefoundintheoperatinginstructions).
■Response time t90:Shortsettingenablethefastestmeasurement.Atlongerresponsetimes,themeasurementsignalis
smoothedandaveragevaluesfortemperatureuctuationsareformedcausedbytheinertialmeasurement.
■The storage mode is turned on when the peak value, minimum value or the average temperatureofthecurrentmeasurement
is to be captured and displayed or used via the outputs.
■Ifaviewingwindowislocatedbetweenthemeasuringobjectandthepyrometer,thetransmittanceofthewindowmustbecon-
sideredduringthemeasurement.Enterthetransmittanceofthewindowinordertoobtainacorrectmeasurementresult.
About SensorTools,thepyrometercanbeupdatedtoanewrmwareversiontoxbugsoraddnewfeatures.SensorTools including
thelatestrmwarecanbedownloadedfromthewebsiteatwww.sensortherm.de/en/download-section(givenbyenteringthemodel
number(rst4characters)andserialnumberrequired).
3. Congure
5. Record /
Analyze
2. Set measurement
parameters
1. Connect the
pyrometer
1. Connect the pyrometer: - automatically (search)
- manually (select COM àconnect)
2. Temperature display: - numerically (as on the pyrometer)
- graphically (displayed in time)
3. Digital inputs / outputs: - shows active inputs or outputs
4. Set measuring parameters: - measuring relevant
- rarely required
( and to extend)
5. Savemeasuringparameters:-saveallvaluesunderalename
6.Alignment: -switchingon/o󰀨lasertargetinglight
(Iconsdevice-dependent) -conguremonitorsettingsofthecameramodule
-setmeasuringdistanceatmotorizedfocus
7. Graphic presentation: - customize view in the data recording window
- select view graphs
8. Record data: - save measurement data incl. all parameters
- customize recording settings
-showmeasurementinformation
- playback and analyze in the viewer
9. CongurationFiles: -savecompletepyrometercongurations
(setups) and activate them on the PC or
externally via digital inputs
10. Deviceconguration: -performbasicdevicesettings
-limittemperaturerangeifnecessary
- adapt analog outputs to terminals
-assignfunctionstodigitalinputs/outputs
- test analog and digital outputs
-accessservicefunctions
-congureinterfaceanddatacollectionsettings
-adjustingthepyrometertoaspecicmeasuringtemperaturevalue(single-pointadjustment)
Measuring temperature
DT: read out device temperature
IN: digital inputs , OUT: digital outputs
Port not activated, inactive, active
Select measurement parameters
or type in or via
quickadjustment(activeeld)
Measuring mode selection
Savepyrometerparametersinle
Loadparametersfromle
Parametersarereadfrompyrometer
Parametersofcurrentlyloadedle
Laser targeting light
Measuringdistanceatmotorizedfocus
Monitorsettingsofcameramodule
Scale per mouse click
Scale per entry
Scale with mouse drag
Adapt to pyrometer’s temp. range
Automatic scale (selected graphs)
2
3
4
5
6
1
10
ProcessSensorsreservestherighttomakechangesinscopeoftechnicalprogressorfurtherdevelopments. Quickstart-Manual_M3_H3_RatioPyrometers_12-pin
(Feb14,2017)
9
7
8
PROCESS SENSORS CORPORATION
IRTemp.SalesO󰀩ce:787SusquehannaAvenue,FranklinLakes,NJUSA•Tel:201-485-8773•Fax:201-485-8770
CorporateHeadquarters:113CedarStreet,Milford,MAUSA•Tel:508-473-9901•Fax:508-473-0715
www.ProcessSensorsIR.com•[email protected] A KPM Analytics Company

Other manuals for METIS M311

1

This manual suits for next models

3

Other Process Sensors Measuring Instrument manuals

Process Sensors METIS M308 Instruction manual

Process Sensors

Process Sensors METIS M308 Instruction manual

Process Sensors MCT466-QC User manual

Process Sensors

Process Sensors MCT466-QC User manual

Process Sensors METIS M311 User manual

Process Sensors

Process Sensors METIS M311 User manual

Popular Measuring Instrument manuals by other brands

HEIDENHAIN MSE 1350 installation instructions

HEIDENHAIN

HEIDENHAIN MSE 1350 installation instructions

Gentec S-LINK user manual

Gentec

Gentec S-LINK user manual

Simpson 897 Operator's manual

Simpson

Simpson 897 Operator's manual

Agreto HFM II user manual

Agreto

Agreto HFM II user manual

hecht 2003 TRANSLATION OF ORIGINAL INSTRUCTIONS FOR USE

hecht

hecht 2003 TRANSLATION OF ORIGINAL INSTRUCTIONS FOR USE

MADDALENA ElecTo Bulk installation instructions

MADDALENA

MADDALENA ElecTo Bulk installation instructions

Nivetec Micronics U1000-HM user manual

Nivetec

Nivetec Micronics U1000-HM user manual

Mastech MS2128A Operation manual

Mastech

Mastech MS2128A Operation manual

Vega VEGAPULS 61 operating instructions

Vega

Vega VEGAPULS 61 operating instructions

Ametek 5830 user manual

Ametek

Ametek 5830 user manual

OHAUS CKW Series Installation and operation instructions

OHAUS

OHAUS CKW Series Installation and operation instructions

Brüel & Kjær 4423 Instructions and applications

Brüel & Kjær

Brüel & Kjær 4423 Instructions and applications

Hach Hach SL1000 Basic user manual

Hach

Hach Hach SL1000 Basic user manual

Montana Instruments CryoCore quick start

Montana Instruments

Montana Instruments CryoCore quick start

ATEQ VT31 user guide

ATEQ

ATEQ VT31 user guide

Taxitronic Skyglass TX80 installation manual

Taxitronic

Taxitronic Skyglass TX80 installation manual

WATANABE ELECTRIC INDUSTRY CO., LTD AP-101-11 instruction manual

WATANABE ELECTRIC INDUSTRY CO., LTD

WATANABE ELECTRIC INDUSTRY CO., LTD AP-101-11 instruction manual

Chauvin Arnoux Ulys MD45 Series quick start

Chauvin Arnoux

Chauvin Arnoux Ulys MD45 Series quick start

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.