IP Control Unit
Installation Guide
Revision 1.0 Dated 20 June 2005
Tel: +44 (0)1442 242 224
1. Introduction to the IP Control Unit
1.1 General Description
The ProCon IP Control Unit allows you to connect your RS232 controlled products to an IP infrastructure and
control them from a single point using the ProCon Site Manager® software.
There are five variants of the ProCon IP Control Unit available, all of which have the following features. See
table 1.1 for a comparison chart of the differences between the variants.
• DHCP or manually configured IP address, subnet mas & default gateway.
• Built in e-mail server so alerts are sent even when Site Manager® software is not running.
• 2 available e-mail addresses for multiple alerting.
• Closed loop that can trigger an e-mail alert when the loop is bro en, allows hardware to act as a
security measure for expensive audio visual equipment.
• 2 built in timers that can trigger alerts for measuring usage, i.e. e-mail gets sent when the filter on a
projector needs changing.
• Projector lamp expiration alert (uses one of the timers), sends an e-mail to notify that a projector
lamp has passed a preset duration and needs changing (requires Site Manager® software to be
running)
• Infra red port for controlling non-RS232 devices such as VCR’s and DVD players.
• Built in scheduling that operates from the onboard cloc allowing events to occur without Site
Manager® software.
8450-02 8455-02 8460-02 8465-02 8701-0
Number of RS232 ports 3 1 3 1 2
Loop through port √ x √ x x
Power extension port √ x √ x x
Battery bac ed rtc x x √ √ √
RS232 Interface 13 pin phoenix D9 male 13 pin phoenix D9 male 3 pin phoenix
Closed loop interface 13 pin phoenix 2 pin phoenix 13 pin phoenix 2 pin phoenix
2 pin phoenix
IR Interface 13 pin phoenix 3.5mm jac 13 pin phoenix 3.5mm jac x
Table 1.1 Comparison of the IP Control Unit variants
1.2 Electrical Specifications
8450-02 8455-02 8460-02 8465-02 8701-0
Supply voltage 12V 12V 12V 12V mains
Supply current (@12V) 250mA 300mA 250mA 300mA X
Power supply included 12V 500mA 12V 500mA 12V 500mA 12V 500mA X
Current drawn with
8416-03 ProCon
Control Panel attached
to power loop through.
375mA
375mA
425mA
425mA
X
Operating temperature 0° - 70° F 0° - 70° F 0° - 70° F 0° - 70° F 0° - 70° F
Table 1.2 Electrical specifications of the IP Control Unit variants