procontrol IP STECKER User manual

Procontrol®
Network Controllable Power Socket Strip
0802-03_R9C revision
May 2012.

© 2012 Procontrol Electronics Ltd.
All rights reserved.
The IPStecker, Worktime, Workstar, WtKomm, Proxernet, are official brand names of Procontrol
Electronics Ltd.
Trademarks in the document are the property of the respective owners. Procontrol Electronics Ltd.
reserves all copyright of the document: it may not be copied for third party, modified and published
without prior written permission of the author.
Procontrol Electronics Ltd. reserves the right to alter the document and the software without notice.
Procontrol Electronics Ltd. assumes no liability for the accuracy for the product, the software and
documentation and also for its adequacy and usability for specific applications.
The software and its documentation is provided „as is”, without warranty of any kind, including but
not limited to the warranties of accuracy or fitness for a particular purpose. In no event shall the
authors be liable for any claim, damages or other liability out of or in connection with the product.

Index
Index.........................................................................................................3
IPStecker..................................................................................................4
Welcome ..................................................................................................................4
Safety Precautions....................................................................................................5
General rights and responsibility..............................................................................5
Introduction..............................................................................................................6
Types: ........................................................................................................................................... 6
Plans for Product Enhancement................................................................................................... 6
Properties, types........................................................................................................................... 7
For English users......................................................................................................9
What kind of Ethernet network we have?..........................................10
1. In Case of Established Computer Network........................................................10
2. Directly Wired Connection between Terminal and PC......................................12
Ethernet data connection establishment.............................................13
Product setup..........................................................................................................13
IPStecker remote control function......................................................14
Testing the IPStecker Ethernet connection ............................................................15
1. Web browser / IP Stecker Online.......................................................................16
Sections of the web interface: ................................................................................17
1. Plugs –Remote access of powers sockets............................................................................... 17
2. Events –User operations log.................................................................................................. 18
3. User –User settings................................................................................................................ 18
4. Connection –Connection settings .......................................................................................... 19
5. Security –Security settings..................................................................................................... 20
6. Date time –Date and time settings......................................................................................... 20
7. Delays –Plug power on delay settings................................................................................... 21
8. Save state –Saving the states of plugs.................................................................................... 22
9. Ping settings –Automatic plug restart (automatic restart of crashed systems e.g., RESET) . 22
10. System –Language settings and device restart/logout......................................................... 23
2. Telnet..................................................................................................................25
3. Command line remote control through user developed program (SDK)...........26
Contact to the manufacturer................................................................30

IPStecker
Procontrol 4
IPStecker
Welcome
Thank you for choosing a Procontrol product.
Procontrol Electronics Ltd has grown to an important national company of
developing and manufacturing software, hardware, electronic devices, access control,
time-attendance systems, queue control, client caller and access protection systems
since 1981.
Thousands of satisfied customers have experienced the security ensured by our long
time period planning, reliable work and the world trademarks standing behind us.
Our qualified staff does its best to satisfy your requirements in the electrical
development.

IPStecker
Procontrol 5
Safety Precautions
Please read this guide before installing and
using the device. Please use the device
properly and as described in the following
manual.
The guarantee is insured only if the device is
used with the implements approved or
specified by the manufacturer, and it is
cleaned and maintained as described in this
guide.
The authors are NOT liable for any claim,
damages or other liability out of:
- using not the proper way
- incorrect installation
- connecting to inappropriate electronic
network
- incorrect maintenance
- not approved modifications,
interventions
- using non-original elements
- using with implements not approved
or specified by the manufacturer
Only the technical service authorized by the
manufacturer is allowed to do interventions in
the device.
Maximum number of connectable devices
using switching power supply is 2/socket!
Do not try to modify or dismount any part of
the device
Do not store and operate the device out of the
given ranges
Only use the device the proper way as
described in guide.
Do not store the device close to a heat source
or direct flame, because the device may
explode
Never allow water or any other foreign matter
to get into the unit. The unit contains sensitive
electronic parts, so water and foreign matter
not only can cause malfunction, they also
create the risk of overheating due to short
circuiting and insulation failure, fire and
smoke, combustion, and electric shock. Should
water or foreign matter ever get into the unit,
immediately turn off the unit and contact a
qualified service person.
Only use the product for it’s intended purpose!
Security
Keep the device in operation only from
electric sources defined in this user manual.
Do not open the device, there are no user
serviceable parts inside!
Attention! Connect the product exclusively
to a grounded power outlet with relay
contact protection network.
To avoid fire and risk of electronic shock:
Beware that your children do not throw or
push objects through the slots of the device.
Do not mount accessories or attachments on
the device that are not designed for this
device. If you do not use the device for longer
time or in case of lightning, you shall unplug
the power cord.
Risks at Installation
Do not store anything on the power cord. Do
not place the device, where the power cord can
be damaged. Do not use the device under wet
circumstances or in humid premises.
Cleaning
Switch off the device before cleaning. Use
slightly wet mop. Excessive humidity may
cause electric shock.
General rights and responsibility
Manufacturing rights of this device are
reserved by Procontrol Electronics Ltd.
Modifying or copying of this device or parts is
prohibited!
Procontrol Ltd. reserves the right to modify
this documentation without prior notice
Procontrol Ltd. is not liable for using of this
device and the consequences of the
application.

IPStecker
Procontrol 6
Introduction
The IP Stecker is an intelligent socket strip with IP address and individually,
remotely controllable power outlets for switching up to four devices on and off
through the Internet and Ethernet using a notebook, pocket PC.
Types:
IPStecker 3
IPStecker 4
IPStecker 4
Plans for Product Enhancement
• We currently provide the two models above - series R9C, both provided with
Ethernet and USB port. The USB (12C) connector is prepared for future
enhancements.
As advanced option you will be able to connect external thermometer sensors
(TS-05 or THS-05) through the USB (I2C) port, for applications e.g.
emergency stop at a certain temperature, i.e. the user sets a threshold value,
when exceeded, the device stops operating. This „Smart Metering” will be
available, when the manufacturing of next series has been launched, which is
at present in the process of development.
A built in current and voltage meter function is planned, this „Smart
Metering” will be available similarly, when the manufacturing of next series
has been launched, which is at present in the process of development.
In case of any requested modification and enhancement please do not hesitate to
contact us, any individual request is highly appreciated. Please contact our colleagues
for details and prices!

IPStecker
Procontrol 7
Properties, types
Type
IPStecker 3
IPStecker 4
Picture
Revision
0802-03-R9C
0802-03-R9C
Part number
141108
141106
Number of remotable switched sockets
3 sockets
4 sockets
Ethernet interface
10/100BaseT
10/100BaseT
Remote abilities
o Web /internet browser
o Telnet
o Command prompt remote control, Perl script,
PHP script
o PCSW protokoll
o Web /internet browser
o Telnet
o Command prompt remote control, Perl script,
PHP script
o PCSW protokoll
Compatibility
Can be used in all operation system, with all
browsers: Microsoft Internet Explorer, Opera,
Mozilla Firefox, Netscape, etc.
Windows 98SE / 2000 / XP / XP SP1-SP2, Server
2003 / Vista / Linux / Me / Mac OS etc.
Can be used in all operation system, with all
browsers: Microsoft Internet Explorer, Opera,
Mozilla Firefox, Netscape,
Windows 98SE / 2000 / XP / XP SP1-SP2, Server
2003 / Vista / Linux / Me / Mac OS
Language
english, hungarian
english, hungarian
Mounting
19 "rack mountable with included metal fixing
brackets
19 "rack mountable with included metal fixing
brackets
Connectors
RJ45, USB B
RJ45, USB B
Socket standard
F (Hungary)
F (Hungary)
Power supply
AC 230V, 50Hz
AC 230V, 50Hz
Power consumption
max: 3 VA
max: 3 VA
Capacity
max: 230V, Σ16A total, max: 230V 8A / socket at
continuous load. Maximum number of devices
using switching power supply is 2/socket.
max: 230V, Σ16A total, max: 230V 8A / socket at
continuous load. Maximum number of devices
using switching power supply is 2/socket.
Needed cable type
CAT5, CAT6
CAT5, CAT6
Support / feedback on hardware
-double-pole main switch
- 1 hidden reset button
- 3+2 pcs status LED
- Ethernet status leds for , a LINK signal and
10/100Mbit mode
- Built-in clock, and memory protection batteries
- 1 hidden reset button
- 3+2 pcs status LED
- Ethernet status leds for , a LINK signal and
10/100Mbit mode
- Built-in clock, and memory protection batteries
Casing
Indoor durable case, compact, distinguished
Indoor durable case, compact, distinguished
Dimensions
Without fixing brackets: 430x60x45mm
With fixing brackets: 480x60x45mm
Without fixing brackets: 430x60x45mm
With fixing brackets: 480x60x45mm
Weight
Net 1000g, gross 1130g
Net 1000g, gross 1140g
Operating temperature
-25 - +50 °C
-25 - +50 °C
Storage temperature
-40 - +60 °C
-40 - +60 °C

IPStecker
Procontrol 8
Operating relative humidity
max. 80%
max. 80%
Storage relative humidity
max. 90%
max. 90%
Standards
Ethernet IEE802
Ethernet IEE802
USB (I2C) - prepared for later
developments
x
x
Smart Metering: current and voltage
measurement functions
under development
under development
* A Special communication protocol developed by Procontrol, which allows the implementation and communication of IPStecker with other Procontrol
manufactured products and systems.
Attention! Maximum number of devices using switching power supply is 2/socket.

IPStecker
Procontrol 9
For English users
If the web interface of the IPStecker is in Hungarian, you can change it to English in
Rendszer section, by changing the dropbox value Magyar to English, and clicking
Mentés button.

What kind of Ethernet network we have?
Procontrol 10
What kind of Ethernet network we have?
(Estimation of Ethernet network topology)
Connect the device to a free end point (or directly to your PC) of an established
Ethernet network as following.
Ethernet on PC network is not everywhere accessible, therefore we suggest two
solutions for testing your device:
1. In Case of Established Computer Network
Connect a free end point of the PC network with a straight patch cable (Straight-
Trough) to the device. We recommend this solution, if possible. Test the device with
a patch cable (Straight-Trough, attached to the customer package) on an Ethernet
socket of a network-connected PC. Connect the Ethernet cable to the SWITCH or
HUB of your PC network (Ethernet).

What kind of Ethernet network we have?
Procontrol 11
o

What kind of Ethernet network we have?
Procontrol 12
2. Directly Wired Connection between Terminal and PC
If a network SWITCH is not available, but you want to connect it directly to the
Ethernet socket of your PC, you need a special Cross-Over wire. Connect the device
to your PC’s built in connector through the Cross-Over patch cable.

Ethernet data connection establishment
Procontrol 13
Ethernet data connection establishment
Product setup
Connect the socket strip to a 230V mains socket outlet. Use a grounded outlet only.
Connect the Ethernet network cable, then turn on the power switch of the device (I O
labeled rocker switch). After about 10 seconds the device is available on the
computer network with default connection settings.
IP address: 192.168.0.250
Subnet mask: 255.255.255.0
Web port: 80
You can now connect the remotely switched 230V powered devices as you wish.
The product is supplied with the relays switched on, so after switching on the first
time, all four sockets will be powered with 1-2-3-4 seconds delay.

IPStecker remote control function
Procontrol 14
IPStecker remote control function
The remote control modes of the IPStecker were developed according to different
customer needs and requests. Controlling the power supply of the connected devices
is available through the following channels:
Web browser port 80 / internet browser (IPStecker Online)
Most of the user's choice, the simplest plausible method for remote
control via an Internet Browser with graphic interface. Most parameters of
the unit are accessible through this default interface. The following
browsers were tested:
a. Internet Explorer 5,6,7,8
b. Mozilla
c. Opera
Telnet port 23 / command line
a. Microsoft Telnet
b. Debian linux –telnet
PCSW protocol, port 1001
Secret internal protocol of Procontrol Ltd., used to edit system parameters
and for firmware upgrades. Only for system administration purposes.
Through web port 80 instead of web browser, even scheduled, or command
line remote control, Perl script, PHP script. ( sample script is available on the
product’s website)
Power supply control of the connected devices is even possible scheduled
through web port 80 (instead of web browser), or controlled by program
code. Tested under the following environment:
a. Microsoft Windows 2000, Windows XP, Windows Vista, Windows
2003 Server, Windows 2008 Server, Windows 7

IPStecker remote control function
Procontrol 15
Testing the IPStecker Ethernet connection
Ping test: enter following command into the command line: PING
192.168.0.250
If you receive a reply, you can try with your browser according to description
below. If you do not receive any reply, check as follows:
FIREWALL DIFFICULTIES: A well operating firewall may prevent the
program from running correctly.

IPStecker remote control function
Procontrol 16
1. Web browser / IP Stecker Online
Power of the IPStecker’s sockets can be individually switched on and off through a
web browser. Access to the control page can be password protected.
FIREWALL DIFFICULTIES: A well operating firewall may prevent the program
from running correctly.
Enter the default IP address into the browser: 192.168.0.250
If the user interface is not displayed, please check:
Whether you established all connections properly?
Whether at least one of the IPStecker’s status LEDs is lit?
Whether your PC’s IP address is in the same network: 192.168.0.xxx?
After displaying the user interface you can enter a new IP address into the IP field of
connection preferences.
To log in, enter the correct password. (default is admin)
To set interface language see section 10 below.

IPStecker remote control function
Procontrol 17
Sections of the web interface:
1. Plugs –Remote access of powers sockets.
The first section of the IPStecker’s user interface displays the current status of
power socket strip. A powered plug is marked green (ON), an unpowered plug
is marked red (OFF).
With a single click on the buttons in the On/Off column, power can be switched
ON or OFF in each plug (R1, R2, R3).
Restarting of each plug is also possible, they remain unpowered till the time delay
set in section Delays. After the time period expires, the plug automatically
switches on, and the web page is being refreshed. Each plug can be renamed by
the user for easier identification in the User section of the web interface. The
names given there are displayed in the User name column.
ATTENTION! ALWAYS USE THE SAVE BUTTON AFTER SETTINGS
MODIFICATION AND DATA ENTRY!

IPStecker remote control function
Procontrol 18
2. Events –User operations log
The device logs each user operation and stores the last 128 event
3. User –User settings
(Operation of the IPStecker is not affected by the settings in this section)
Each plug can be renamed (according to the connected devices e.g.) by the user
for easier identification in this section. The names given here are displayed in the
User name column of the first section. A maximum 10 character long name can
be given to each plug with contents of the English alphabet.

IPStecker remote control function
Procontrol 19
4. Connection –Connection settings
Parameters of the connection with the IPStecker can be changed here: IP address,
default gateway, subnet mask, TCP/IP port.

IPStecker remote control function
Procontrol 20
5. Security –Security settings
A password can be set here to access the IPStecker’s web interface. The password
can be changed any time inside the control page. If you set and save a password here,
the device asks for it the next time you want to log in. The default password is
“admin”. (Recommended to change it after the first login)
The Current state column gives information if a password is required to enter the web
interface. If you do not wish to use a password, just leave the New settings field
empty and click the Save setting button. The next login can be done without using a
password. To restore password controlled access, it is only needed to type in a new
password and click the Save setting button.
6. Date time –Date and time settings
The actual date and time can be set in this section. Certain types of IPStecker can
automatically synchronize date and time data from an NTP server.
Other manuals for IP STECKER
1
Table of contents