61195878L1-13B, April 2005 www.procurve.com Copyright 2005 Hewlett-Packard Development Company, LP
Quick Start Guide 5990-8895
ProCurve Secure Router dl 1xE1 + G.703 Module
J8455A
SPECIFICATIONS
Operating
Modes E1/FE1 Frame Relay, E1/FE1 PPP
E1/FE1
Interface Line Rate: 2.048 Mbps ±50 PPM
Line Code: AMI or HDB3
Framing: FAS with optional CRC-4
FE1 Line Rate: Channelized timeslot (in multiples of
56/64 kbps)
Receiver Sensitivity: -30 dB
Connector: RJ-48C
G.703 Interface Line Interface: Per ITU-T G.703
Line Rate: 2.048 Mbps, ±50 PPM
Line Code: AMI or HDB3
Framing: FAS with Optional CRC-4
Receiver Sensitivity: -30 dB
Capacity: 1 to 31 timeslots
If timeslot 16 signaling is used on the drop port, a maximum
of 15 timeslots can be mapped to router
(1 to 15 or 17 to 31).
Connector: RJ-48C
Clock Source Network, internal, and through
Diagnostics Test Pattern Generation and Detection: QRSS, 511,
all ones, all zeros
Network loopbacks
Alarm generation and detection
Network performance data (15 minutes and 24 hours)
Standards FCC Part 15 Class A, EN 55022 Class, EN 55024,
EN 61000-3-2, EN 61000-3-3
ACIF S016, ETSI TBR 12/TBR 13
EN60950, AS/NZS 60950
ITU G.603, ITU-T G.704 (CRC-4), ITU-T G.823,
ITU-T G.797
Physical Dimensions: 6.99 cm (2.75 in) W x 10.80 cm (4.25 in) D
Operating Temperature: 0°C to 50°C (32°F to 122°F)
Relative Humidity: Up to 95 percent, noncondensing
at 30°C (86°F)
Non-Operating Temperature: -20°C to 70°C (-4°F to 158°F)
Non-Operating Relative Humidity: Up to 95 percent,
noncondensing at 30°C (86°F)
Altitude: Up to 3.05 km (10,000 ft)
INSTALLATION INSTRUCTIONS
1. Remove power from the unit.
2. Slide the interface module into the option slot until the interface module
is firmly seated against the chassis.
3. Secure the screws at both edges of the interface module.
4. Connect the cables to the associated device(s).
5. Complete the installation of the base unit.
6. Restore power to the unit.
Note For safety information for the routers and all modules,
please refer to the safety and ESD precautions in the
ProCurve Secure Router Installation Guide included
in your router shipment.
E1 NETWORK (RJ-48C) CONNECTION PINOUT
Pin Name Description
1 R1 Receive data from the network
2 T1 Receive data from the network
3 — Unused
4 R Transmit data toward the network
5 T Transmit data toward the network
6-8 — Unused
G.703 (RJ-48C) CONNECTION PINOUT
Pin Name Description
1 R Transmit data toward the DTE
2 T Transmit data toward the DTE
3 — Unused
4 R1 Receive data from the DTE
5 T1 Receive data from the DTE
6-8 — Unused
61195878L1-13B, April 2005 Printed in the USA Copyright 2005 Hewlett-Packard Development Company, LP
Quick Start Guide 5990-8895
ProCurve Secure Router dl 1xE1 + G.703 Module
J8455A
remote-loopback
Enables acceptance of remote loopback requests on this E1 interface. Deny
acceptance using the no remote-loopback command. This setting is enabled
by default.
sa4tx-bit [0 | 1*]
Assigns a value to the Tx spare bit in position 4.
show test-pattern
Shows the current test pattern error count.
shutdown
Turns off the interface. By default, all interfaces are disabled. Use the no
shutdown command to enable the interface and allow it to pass data.
snmp trap link-status
Enables the interface to send SNMP traps when there is an interface status
change and controls the SNMP variable, ifLinkUpDownTrapEnable.
tdm-group <group#> timeslots <DS0 range> speed [56 | 64*]
Creates a group of contiguous DS0s on this interface to be used during the
bind process.
<group#> Number label (1 to 1024) to identify this TDM group.
<DS0 range> DS0s in this group in the form: <starting DS0 - ending
DS0>.
56 | 64* (Optional) Specifies a channel rate of 56 kbps or
64 kbps.
test-pattern [clear | insert | ones | p511 | qrss | zeros]
Initiates sending the specified test pattern.
clear Clears the test pattern error count.
insert Inserts an error into currently active test pattern.
ones Generates continuous ones.
p511 Generates repeating pattern of ones and zeros.
qrss Generates a random pattern.
zeros Generates continuous zeros.
ts16
Enables timeslot 16 multiframe to be checked on the receive signal.
* Indicates default values.
Note This command list is an illustration of available
commands. For complete command descriptions and
default values, refer to the SROS Command Line
Interface Reference Guide provided on your
ProCurve SROS Documentation CD.
Note An optional backup module is required for backup
applications.
For a description of the backup connection pinouts,
refer to the Quick Start Guide included with your
backup module
E1 + G.703 INTERFACE MODULE COMMANDS
clock source [line* | internal | through]
Configures the clock source for the system. The 1xE1+G.703 module supports a
single clock source for both E1 interfaces.
line* Recovers clock from the E1 circuit.
internal Provides clocking using the internal oscillator.
through Recovers clock from the circuit connected
to the G.703 interface.
coding [ami | hdb3*]
Configures the line coding for the E1 or G.703 physical interface. This setting
must match the line coding supplied on the circuit by the service provider.
ami Specifies Alternate Mark Inversion.
hdb3* Specifies High-Density Bipolar 3.
framing [crc4]
Configures the framing format of the E1 interface.
crc4 Enables CRC-4 framing.
loop-alarm-detect
Enables detection of loop alarms on the E1 interface. Use the no form of this
command to disable loop alarm detection. This setting is enabled by default.
loopback network [line | payload]
Initiates a loopback on the interface toward the network. Deactivate using the
no loopback network command.
line Initiates a metallic loopback of the physical E1
network interface.
payload Initiates a loopback of the E1 framer (CSU portion) of
the E1 network interface.
loopback remote v54
Initiates an E1 remote loopback test (with a V54 loopback pattern). Deactivate
using the no loopback remote v54 command.
remote-alarm [rai* | ais]
Selects the alarm signaling type to be sent when a loss of frame is detected on
the E1 receive signal.
rai* Specifies Remote Alarm Indication.
ais Specifies Alarm Indication Signal.

Other ProCurve Network Router manuals

ProCurve J8451A User manual

ProCurve

ProCurve J8451A User manual

ProCurve J8454A User manual

ProCurve

ProCurve J8454A User manual

ProCurve J8452A User manual

ProCurve

ProCurve J8452A User manual

ProCurve 7102dl User manual

ProCurve

ProCurve 7102dl User manual

ProCurve J8463A User manual

ProCurve

ProCurve J8463A User manual

ProCurve J8753A User manual

ProCurve

ProCurve J8753A User manual

ProCurve J8458A User manual

ProCurve

ProCurve J8458A User manual

ProCurve J8752A User manual

ProCurve

ProCurve J8752A User manual

Popular Network Router manuals by other brands

Fritz!Box 6890 Configuration and operation

Fritz!Box

Fritz!Box 6890 Configuration and operation

TP-Link TD-W8961NB user guide

TP-Link

TP-Link TD-W8961NB user guide

Edimax BR-6428nS V2 user manual

Edimax

Edimax BR-6428nS V2 user manual

TP-Link RE355 Quick installation guide

TP-Link

TP-Link RE355 Quick installation guide

SSV IGW/936-L Hardware reference

SSV

SSV IGW/936-L Hardware reference

Linksys EA8500 user guide

Linksys

Linksys EA8500 user guide

Dynex DX-wegrtr - Enhanced Wireless G Router user guide

Dynex

Dynex DX-wegrtr - Enhanced Wireless G Router user guide

Hawking H-BR49 user manual

Hawking

Hawking H-BR49 user manual

TP-Link TL-PA8030P Quick installation guide

TP-Link

TP-Link TL-PA8030P Quick installation guide

Axel AX3000 Platine 65E installation guide

Axel

Axel AX3000 Platine 65E installation guide

TP-Link JetStream TL-SL3428 installation guide

TP-Link

TP-Link JetStream TL-SL3428 installation guide

Allied Telesis AT-IE510-28GSX-80 installation guide

Allied Telesis

Allied Telesis AT-IE510-28GSX-80 installation guide

Ubiquiti EdgeRouter PoE ERPoe-5 quick start guide

Ubiquiti

Ubiquiti EdgeRouter PoE ERPoe-5 quick start guide

TP-Link TL-R402M Basic setup

TP-Link

TP-Link TL-R402M Basic setup

X-Micro WLAN 11g user manual

X-Micro

X-Micro WLAN 11g user manual

Mako Networks Mako 6500-A2 Product handbook

Mako Networks

Mako Networks Mako 6500-A2 Product handbook

Lenovo Flex System EN2092 user guide

Lenovo

Lenovo Flex System EN2092 user guide

LEGRAND DA1054 user guide

LEGRAND

LEGRAND DA1054 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.