PROSPERITY GROUP TRAXON e:cue 3 mx Specification sheet

AS086160055, tba
e:cue
Lighting Control Engine 3 mx
Information for Use
Edition:
14.04.23 [EN_LCE3mx_Setup_v1p0]
Published by:
Traxon Technologies Europe GmbH
Karl-Schurz-Strasse 38
33100 Paderborn, Germany
©2023 Traxon Technologies Europe GmbH
All rights reserved
Read the Information for Use and the Safety Instructions
carefully. Subject to modication without prior notice.
Typographical and other errors do not justify any claim for
damages. Modication of the product is prohibited.
This document is designed for electricians and system
administrators of the product.
All product names and trademarks mentioned in this manual are
trademarks of their respective owners.
Except for internal use, relinquishment of the instructions to a
third party, duplication in any type or form - also extracts - as
well as exploitation and / or communication of the contents is not
permitted.
Traxon Technologies Europe GmbH
Sales Operations
Karl-Schurz-Str. 38
33100 Paderborn, Germany
+49 5251 54648-0
Downloads and more information at:
www.ecue.com

WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 04/23 Sheet: 02 / 12
Table of ContentsTable of Contents
1 Safety instructions 03
1.1 Symbols 03
1.2 General safety instructions 03
2 General device description 03
2.1 Delivery content 04
2.2 Optional accessories 04
2.3 Connectors and Interfaces 05
2.4 Product specications 06
3 General remarks 06
3.1 Transport 06
3.2 Unpacking 06
3.3 Warranty regulations 06
3.4 Maintenance and Repair 07
3.5 Disposal 07
3.6 Support 07
4 Installation 07
4.1 Mounting 08
4.2 Power supply 08
5 Conguration 08
5.1 LCE3MX Operation 08
5.2 Setup 08
5.3 Network Settings LCE3MX 09
5.4 Network Settings SYMPHOLIGHT 09
5.5 Network Settings LAS 10
6 Dismounting 10
7 Certications 11
8 Dimensions 11
Lighting Control Engine 3 mx — Information for Use | Table of Contents

WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 04/23 Sheet: 03 / 12
1 Safety instructions
Please read the safety instructions, provided in a separate manual, carefully. Make sure that the
environmental, mounting, and installation prerequisites are met. This manual should be kept at a safe place
and in reach of the device.
1.1 Symbols
!
The exclamation mark warns about possible
damage of the device itself, to connected devices,
and to the user.
i
The information symbol gives general hints and
informs about handling and procedures for use of
the device.
1.2 General safety instructions
2 General device description
Designed to control small to medium projects, the Lighting Control Engine 3 mx (LCE3MX) is a high
performance server with two e:cue software applications installed. As a central control unit, this versatile
lighting control server orchestrates all devices and xtures within a project. With the ability to output e:net
and the capability to integrate various external engines, triggers, and other desired devices and content, the
!
— To prevent electric shock hazard or damage to the
equipment, disconnect the power cord to remove power
from the server. Portions of the power supply and some
internal circuit remain active until power is removed.
— Device components inside the system can reach high
temperatures. Do not open the system while in operation.
Repairs may only be carried out by authorized, specially
trained personnel. When in doubt, contact Traxon e:cue
service.
— To avoid short circuits, keep paper clips, screws, and
staples away from connectors, slots, sockets, and
circuitry.
— Avoid dust and humidity. Do not place the device in any
area where it may become wet.
i
— Installation and maintenance of this product must be
performed by qualied individuals who are knowledgeable
about the procedures, precautions, and hazards
associated with the product.
— To prevent the device from overheating, only operate it in
well-ventilated environment. Cooling ns may not be
obstructed. Do not install next to heat emitting sources or
in a place subject to direct sunlight.
— Seek professional assistance before using an adapter or
extension cord. These devices could interrupt the
grounding circuit.
— If safety instructions are missing, please contact Traxon
e:cue to receive a new copy.
Lighting Control Engine 3 mx — Information for Use | Safety instructions
content

WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 04/23 Sheet: 04 / 12
LCE3MX is the ultimate solution for medium-sized projects: from automation to DALI projects up to
architectural illumination. With e:cue SYMPHOLIGHT and e:cue Lighting Application Suite, the LCE3MX
oers two fully equipped professional lighting control solutions. The LCE3MX can be mounted on DIN rails
with the optional DIN rail adapter brackets, on walls, and in 19 inch racks mounted on a rack drawer.
HighlightsoftheLCE3MX
yEquipped with e:cue’s SYMPHOLIGHT and e:cue’s Lighting Application Suite
yHigh quality components for reliable uninterrupted operation, certied for industrial use
yFanless operation, SSD drive, no moving or rotating parts
ySupport for a variety of Ethernet-based protocols
yEasily mountable on DIN rail (not included) or on walls
ySupports headless operation (no keyboard and monitor connected)
ye:cue quality: tested and optimized for SYMPHOLIGHT
ySYMPHOLIGHT and LAS licenses included
yPower supply included
yWindows 10 LTSC, 10 years security updates
y5 years support
y5 years warranty
2.1 Delivery content
Delivery content of the e:cue Lighting Control Engine 3 mx -
Product number tba or AS086160055::
1. e:cue Lighting Control Engine 3 mx
with ETL tba
with CE only AS086160055
2. Microsoft® Windows 10™
3. e:cue SYMPHOLIGHT & License dongle
4. e:cue Lighting Application Suite License dongle
5. Power cords with Schuko, US and UK plugs
6. Welcome card, Safety instructions
2.2 Optional accessories
yEthernet Data Cable (RJ45) AA556130055
ySYMPL Switch AM313830035
Lighting Control Engine 3 mx — Information for Use | General device description
content

WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 04/23 Sheet: 05 / 12
2.3 Connectors and Interfaces
On / O2 x USB 2.02 x RS-232/-485
Cooling Fins
HDD LED
Power LED Reset switchAC loss switch
Antenna4 x RS-232Power supply 12 V DC
2 x USB 3.0
2 x e:net (RJ45)
VGA
HDMI
Antenna
2 x Audio Jack
2 x USB 3.0
Lighting Control Engine 3 mx — Information for Use | General device description
content

WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 04/23 Sheet: 06 / 12
2.4 Productspecications
Dimensions
(W x H x D)
174 x 148 x 57 mm/
6.85 x 5.83 x 2.24 in (incl. mounting
brackets)
Weight 1.35 kg / 2.98 lb (incl. mounting
brackets)
Power supply input External 12 V DC, 5 A
Power consumption 60 W
Operating temperature -10 ... 60 °C / 14 ... 140 °F
Storage temperature -20 ... 70 °C / -4 ... 158 °F
Operating / storage
humidity
5 … 95% RH, non-condensing
Housing Metal
Mounting Wall mouting
Battery Yes (1)
Certi cations CE, FCC, UKCA, ETL optional
Engine
Operating system Microsoft® Windows 10™
LAN chipset 2 x Gigabit Ethernet, Wake on LAN function
System connection
ports
2 x e:net (RJ45 Ethernet for GbE)
4 x RS-232
2 x RS-485/232
4 x USB 3.0 and 2 x USB 2.0
HDMI
VGA
2 x Audio jack
Data storage 256 GByte SSD mSATA HDD
User interfaces AC loss switch
Power button & LED
Reset button
HDD LED
3 General remarks
3.1 Transport
Only transport the device in its original packaging. This protects the device from damage.
3.2 Unpacking
Only unpack the e:cue LCE3MX at its installation location. To protect the device against condensation water,
unpack it and wait until all moisture remaining in the device has evaporated. Condensation can occur when
the device is moved from a cold to a warm location. Keep the packaging for use in case of further transport.
Inspect all parts for completeness regarding chapter „2.1 Delivery content“ on page 04. If there is
apparent damage to the device or parts are missing from the delivery scope, please contact the Traxon e:cue
Support service.
3.3 Warrantyregulations
Depending on the product, warranty regulations are of dierent duration. The warranty time is usually noted
Lighting Control Engine 3 mx — Information for Use | General remarks
content

WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 04/23 Sheet: 07 / 12
in the quote and in the order conrmation. See www.traxon-ecue.com/terms-and-conditions for details. Legal
warranty regulations apply in any case.
3.4 MaintenanceandRepair
Only external cleaning might be necessary. This cleaning may only be carried out by skilled personnel. To
clean the device, disconnect it from the line power supply. Disconnect all devices connected to the server. Do
not use any cleaning agents containing solvents (e.g. acetone, alcohol, or thinner) or abrasives. The housing
surface can be cleaned with a moist, lint-free cloth. Ensure that no water penetrates into the housing.
Otherwise, this could damage the electronics.
IncaseofreturningtheLCE3MX
When returning the LCE3MX for any reason, e.g. for exchange, be sure to watch the following note:
Always care for proper backup of all user data like shows, images and media les. Data backup is
responsibility of the user, Traxon e:cue cannot guarantee that user data are kept.
3.5 Disposal
The proper disposal of packing materials and of the device is the responsibility of the respective user and for
his account; in all other matters, the retrieval obligation for packing materials and the device is subject to the
statutory regulations.
3.6 Support
In case of technical problems or questions regarding installation and repair please contact:
Traxon Technologies Europe GmbH
Customer Service
Karl-Schurz-Str. 38
33100 Paderborn, Germany
+49 (5251) 54648-0
4 Installation
The installation of the LCE3MX consists of mounting the device, system ports connections and to power
supply. The sequence of cabling is not dened.
!
— Before dismounting, appropriate measures must be taken
to protect the respective components against damage
caused by electrostatic discharge (ESD protection).
— Do not try to repair the device. Return it to your Traxon
e:cue distributor for replacement or repair.
Batteries and technical appliances must not be disposed of
with domestic waste, but should be handed in at the
appropriate collection and disposal points.
!
When adding or removing devices to or from the system,
ensure that the power of the LCE3MX is turned o before
the signal cables are dis-/connected.
Lighting Control Engine 3 mx — Information for Use | Installation
content

WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 04/23 Sheet: 08 / 12
4.1 Mounting
Place the device on a stable surface.
You can mount the LCE3MX in racks as well as on walls or on DIN rails. As delivered, the LCE3MX is
congured for wall mounting. Use the mounting holes to fasten the LCE3MX at a secure and well ventilated
place. Place the cooling ns in a vertical orientation. Ensure proper strain relief for the connected cables.
When mounting the LCE3MX in a rack, ensure that the server rack is suciently ventilated.
4.2 Power supply
Connect the LCE3MX with the provided power cord to mains.
5 Conguration
The LCE3MX runs on Microsoft® Windows 10™ as operating system. It enables you to run lighting control
applications as e:cue’s SYMPHOLIGHT and e:cue’s Lighting Application Suite (LAS) on the LCE3MX. When
rst powering the LCE3MX, a setup of the server is required. Set the network properties for the LCE3MX
and the lighting control applications afterwards.
5.1 LCE3MXOperation
Connect a display and input devices (keyboard, mouse) to the LCE3MX. Display and input devices are always
necessary when accessing any application or settings on the LCE3MX. Connect with the power supply and
switch on the LCE3MX with the power button.
You can hot swap all devices to the LCE3MX.
5.2 Setup
Boot the LCE3MX by pressing the On/ O button. Windows starts its usual setup. Follow the instructions.
You can change the keyboard layout to your needs and also set your time zone which matters for the lighting
show execution.
Windows is set to automatic login. For other cases, these are the login credentials:
The default user name is: ecue
The default password is: ecue2018!
The LCE3MX has a second, backup user account prepared for safety or support reasons. Keep the account
and do not change its settings: ecueBackup (user name), ecueBackup2018! (password). Especially in case of
a forgotten password for the rst account, accessing the user congurations through the backup account
resolves the issue.
i
Do not switch o the server with the main switch or by
removing the power supply, but use the Windows shutdown
function to prevent loss of data.
i
— Provide an Internet connection for the LCE3MX on setup.
If necessary, with a running DHCP server to have an IP
address assigned. Update Windows, SYMPHOLIGHT and
the LAS. Enable and execute updates whenever available.
— Recommendation: Use the default power plan “ecue”. Do
not use a power manager modus which includes “sleep“
since the LAS does not prevent a system shutdown. As
per default, the high performance power management
plan does not allow sleep modus.
Lighting Control Engine 3 mx — Information for Use | Conguration
content

WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 04/23 Sheet: 09 / 12
5.3 NetworkSettingsLCE3MX
Additionally to the network connection to the Internet, the LCE3MX is equipped with a second network
adapter. This enables the integration of the LCE3MX into the network of the lighting installation. Congure the
network properties for the LCE3MX as in every Windows OS, according to your network requirements:
5.4 NetworkSettingsSYMPHOLIGHT
The e:cue SYMPHOLIGHT application is pre-installed on the LCE3MX. SYMPHOLIGHT is a software
application to design, test, and program medium to very complex lighting designs. Developed with superior
usability in mind, e:cue SYMPHOLIGHT is a simple yet powerful lighting control software with an intuitive
graphic user interface, based on advanced timeline programming. For SYMPHOLIGHT to communicate with
the network devices in the installation, SYMPHOLIGHT has to be adjusted to the same network as all the
other network components. The next steps describe how to set the network address in SYMPHOLIGHT. For
further information about SYMPHOLIGHT, please refer to the SYMPHOLIGHT User Manual.
1. Start the SYMPHOLIGHT application.
2. Click on Tools in the top left menu and select Application Settings:
3. In the pop up window Application Settings click on Network:
4. Enter or select the IP address(es) of your network at Interfaces for e:net.
5. Click OK to apply the changes. The pop up window closes and the network settings for
SYMPHOLIGHT are now congured.
Notice that only the network settings for the SYMPHOLIGHT application have been set now. If you have
further network devices installed, each of these devices have to be congured separately. See the
SYMPHOLIGHT Setup Manual for details.
i
Use the preferred dedicated local network range
192.168.123.xxx with one system-internal network adapter.
Lighting Control Engine 3 mx — Information for Use | Conguration
content

WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 04/23 Sheet: 10 / 12
5.5 NetworkSettingsLAS
The e:cue LAS is pre-installed on the LCE3MX. The LAS is a software for creating light shows and controlling
complex lighting projects, and to control your network and all devices in it. For the LAS to communicate with
the network devices in the installation, the LAS has to be adjusted to the same network as all the other
components. The next steps describe how to set the network address in the LAS. For further details on the
LAS, see the System Manual e:cue LAS.
1. Start the Programmer Enterprise.
2. Click on Extras and select Application Options:
3. Under the Advanced tab, you can specify which network card the programmer software e:net outputs
to. You can specify this setting for the Art-Net and KiNet protocols. e:cue recommends only outputting
one protocol per network:
4. Click OK to apply the changes. The network settings for the LAS are now congured.
Notice that only the network settings for the SYMPHOLIGHT application have been set now. If you have
further network devices installed, each of these devices have to be congured separately. For further details
on the LAS, see the System Manual e:cue LAS.
6 Dismounting
Disconnect all attached cables. Dismount the e:cue LCE3MX by unfastening the device. The dismounting is
completed.
!
Before dismounting, appropriate measures must be taken to
protect the respective components against damage caused
by electrostatic discharge (ESD protection).
Lighting Control Engine 3 mx — Information for Use | Dismounting
content

WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 04/23 Sheet: 11 / 12
7 Certications
Only tba:
Conforms to ANSI/UL Std. 62368-1
Certied to CSA Std. C22.2 NO. 62368-1
8 Dimensions
All dimensions in mm
195
182
174
148 105
52.5
57
4000805
Lighting Control Engine 3 mx — Information for Use | Certications
content
This manual suits for next models
1
Table of contents
Popular Controllers manuals by other brands

sauter
sauter equitherm M60 operating instructions

Evco
Evco c-pro 3 nano CHIL Applications manual

GE
GE 90-30 PLC Installation and Hardware Manual

YASKAWA
YASKAWA E1000 Technical manual

PERFECTPASS
PERFECTPASS MasterCraft 2007 Troubleshooting

Promation Engineering
Promation Engineering P1-12VN4 AC Installation & operation manual