Protect MultiCard User manual

Version 1.2
PROTECTGLOBAL.COM
C
Installation Manual

PROTECT MultiCard™
2
Table of contents
1. Introduction to PROTECT MultiCard......................................................................3
2. Prepare main PCB..................................................................................4
3. Make sure to install the MultiCard securely using supplied washers, spacers and screws .................................4
4. Common features ..................................................................................5
5. MultiCard diagram .................................................................................6
6. Operational modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.1. Panic function mode with separated fault outputs........................................................7
6.2. ATM protection mode on PROTECT 600i with separated fault outputs ...........................................8
6.3. ATM protection mode on PROTECT 1100i with separated fault outputs..........................................10
6.4. ATM protection mode on PROTECT 2200i with separated fault outputs..........................................12

PROTECT MultiCard™3
1. Introduction to PROTECT MultiCard
This manual refers to PROTECT MultiCard hardware version 1.0 and software version 1.04.
The MultiCard adds the following functionality to the PROTECT Fog Cannon:
• Panicreleasefunctionality
• ServiceDisablefunctionality(Blocking)bypushbuttonordedicatedinput
• Pumptest/primingbypushbutton
• Separationofvariousfaultconditionsondedicatedoutputs
• ATMprotectionmodeonPROTECT600i,PROTECT1100iandPROTECT2200i
IMPORTANT NOTICE!
The MultiCard will not operate with fog cannon units using software versions before version 2.50.
Different software features are available, depending on the software version of the fog cannon and the
software version of the MultiCard. See notes on this for each individual program function listed in this
document.

PROTECT MultiCard™
4
2. Prepare main PCB
Conictingplasticcollar
OnsomefogcannonunitsaserviceconnectoronthemainPCBmayhavetobemodiedtogivespace
enough to install the MultiCard
Ifthisisthecaseuseaworkknifetoremovetheconictingplasticcollar.
3. Make sure to install the MultiCard securely using supplied washers,
spacers and screws
Correct alignmentBadalignment
The connector on the MultiCard MUSTalignproperlywiththeconnectoronthemainboard,andmounting
holesintheMultiCardmustalignwithspacersbeforeattemptingtoinstallthescrews.

PROTECT MultiCard™5
4. Common features
Under power uptheLED’swillashinanalternatingpattern(Blue-Green-Blue....Blue-Green-Blue....)
forapproximately5-10seconds,andwillthenstartindicatingthestatesaslistedabove.
Pleasenotethatdipswitchsettings,ontheMultiCard,maybemanipulatedduringnormaloperation.
ThiswillhoweverresetprogramowontheMultiCardbacktoitsinitialstageforthatparticularsetting.
Also,precautionsshouldbetakentopreventunwantedfogreleasethatmaybecausedbyDipswitchmanipula-
tion.
Inputs:
Type OpticallyisolatedBidirectionalDCinput
Activationlevel(guaranteedON) 7–30VDC(Max)
Notactivated(guaranteedOFF) 0–1VDC
Current 2mA@12V,4mA@24V
Outputs:
Type OpticallyisolatedBidirectionaloutput
Overloadprotectedsolidstaterelay
Max Rating 120mAcontinuous/30VDC(20VAC)
ONresistance Typical28Ohm(Max35Ohm)
Buttons:
Service TogglesBlockingmode(servicemode)
Test Forpriming/testingpumpatverylowowandfor3secondsatatimemax
LED’s
Green
Flashing slow: Notconnected–startingup
Constantly on: ConnectedtomainPCB–CommunicatingOK
Flashing fast: Test shot is running
Blue Flashing:MachineisinBlockingmode(servicemode)

PROTECT MultiCard™
6
5. MultiCard diagram
Armed
Disable
Fire Alarm
Primary
Trig
Secondary
Trig
12V Out
-
+
-
+
-
+
-
+
-
+
-
+
-
+
12V Out
-
+
12V
-
+
Alarm trig
Normally Open
when alarm system
is activated (Night)
Closed when alarm
system is disabled
(day)
Fog
Fault
Fluid
Com
NC
NO
Com
NC
NO
Com
NC
NO
V +
Vss
Out
1
In
2
In
3
In
4
Out
2
Out
3
Out
4
Out
5
Out
6
Out
7
Out
8
Out
9
Zone Fluid
Zone Fault
Zone Fog
Zone E1 Fault, M ains supply lost
Zone E3 Fault,Fire Alarm active
Zone E4,E5,E6 Fault,battery error
Zone E7,E8 Fault,High/low PCB temp
Zone E9 Fault,Temp sensor error
Zone E10 Fault,Heat rod error
Zone E12 Fault,Pump time out error
Zone E13 Fault,12V out overload
Disable
Blocking M ode
Panic Release
Panic Release
Blocking M ode
Disable
Error
E1
Error
E3
Error
E4 E5 E6
Error
E7 E8
Error
E9
Error
E10
Error
E12
Error
E13
Zone E16 Panic Release
Panic Release
E16
Alarm panelFog Cannon
PIR
Movement Detector
MultiCard

PROTECT MultiCard™7
6. Operational modes
6.1. Panic function mode with separated fault outputs
Softwarerequirement,fogcannon:Softwareversion2.50orhigher.
Softwarerequirement,MultiCard:Softwareversion1.02orhigher.
Devicerequirement:ThisprogramwillrunonanytypeofPROTECTFogCannon.
Dipswitchsettings:
1
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
9
0
10
0
Terminal “V+” iscurrentlynotused,andshouldbeleftunconnected.
For the Panic Release function to work, the following conditions must be met:
• The Disable input on the fog cannon’ mainboard must be inactive
- UsetheDisableinputontheMultiCardinstead,sincethisinputwillnotinuencethePanicsignal
• The Fire Alarm input on the fog cannon’ mainboard must be inactive
- TheFireAlarminputISDESIGNEDTOSTOPANDBLOCKALLFOGimmediately
- Thisisamandatoryfunctiondemandedbynationalandlocalreauthorities,whenusedinpremises
monitoredbyrealarmsystems,andhencemaynotandcannotbeoverruled
- Ifservicedisablefunctionalityisrequested,forservicingattachedalarmsystem,pleaseusethe
SSinputontheMultiCardinstead.Itwasdesignedspecicallywiththispurposeinmind
• Dipswitch 9 on the fog cannon’ mainboard must be set to ON, to enable Panic functionality
Thisinputisxed“normallyopen”(activateswhenvoltageisapplied).
Outputs 2 to 9signalvariousfaultconditionsonseparateoutputs.
Seelistabove.
Do NOT rely solely on the fault indicating outputs on the MultiCard.
Fault, Fluid and Fog outputs on fog cannon mainboard should still be monitored for activity.
Inputs functionality:
IN-SS Activates“Blockingmode”whenconnectedtogndonmainboard
IN-2 Panicbutton
IN-3 Disable(thisDisableinputallowsPanictowork.Willnotturnoffheat)
IN-4 Nofunction
Outputs functionality:
OUT-1 Panicreleaseactive
OUT-2 E1_MAINS_VOLTAGE_LOST
OUT-3 E3_FIRE_ALARM_ACTIVEorE16_PANNIC_NOT_RELEASED
OUT-4 E4_BATTERY_VOLTAGE_LOWorE5_BAT_CHARGE_TIMEOUTorE6_BAT_LOADTEST_FAIL
OUT-5 E7_BOARD_TEMP_HIGHorE8_BOARD_TEMP_LOWorE14_BAT_TEST_CIRC_FAIL
OUT-6 E9_TEMP_TERM_HIGH
OUT-7 E10_TEMP_TERM_LOW
OUT-8 E12_PUMP_TIMEOUT
OUT-9 E13_AUX_12V_OVERLOAD

PROTECT MultiCard™
8
6.2. ATM protection mode on PROTECT 600i with separated fault outputs
Softwarerequirement,fogcannon:Softwareversion2.60orhigher.
Softwarerequirement,MultiCard:Softwareversion1.03orhigher.
Devicerequirements:ThisprogramisspeciallydesignedforPROTECT 600i ONLY!
Attemptstousethisfeatureonothermachinesmayresultinunpredictedbehavior.
Dipswitchsettings:
1
1
2
0
3
0
4
0
5
0
6
0
7
Fog 2
8
Fog 2
9
Fog 3
10
Fog 3
Terminal “V+” iscurrentlynotused,andshouldbeleftunconnected.
ThisprogramfunctionalityhasbeenspeciallytailoredforprotectionofATMmachines.
Itcombinesthreedifferenttriggermethodswithindividualfogsettings.
Input 2 is intended for connection to detectors that detect attempts to manipulate the ATM shutter.
Ifitisactivated,itwillreapreselectedwarning shot to deter anyone from manipulating the shutter
mechanism.
Alimitofmaximum3shotsispossible.ThiswillberesetbyDisablesignalonthemainboard.
Aminimumbreakof5minutes(blockingtimer)betweensuch“warningactivations”isrequired.
Thisfeatureistolimittheamountoffoguidthatmaybewastedduetothistypeofmanipulation.
Thisinputisxed“normallyclosed”(activateswhenNOvoltageisapplied).
Inputs functionality:
IN-SS Activates“Blockingmode”whenconnectedtogndonmainboard
IN-2 ATMshuttermanipulation(normallyclosed)
IN-3 Seismic,glassbreakand/orgassensor(normallyclosed)
IN-4 Nofunction
Outputs functionality:
OUT-1 Foghasbeenactivated(willstaycloseduntilDisableisactivatedonmainboard)
OUT-2 E1_MAINS_VOLTAGE_LOST
OUT-3 E3_FIRE_ALARM_ACTIVEorE16_PANNIC_NOT_RELEASED
OUT-4 E4_BATTERY_VOLTAGE_LOWorE5_BAT_CHARGE_TIMEOUTorE6_BAT_LOADTEST_FAIL
OUT-5 E7_BOARD_TEMP_HIGHorE8_BOARD_TEMP_LOWorE14_BAT_TEST_CIRC_FAIL
OUT-6 E9_TEMP_TERM_HIGH
OUT-7 E10_TEMP_TERM_LOW
OUT-8 E12_PUMP_TIMEOUT
OUT-9 E13_AUX_12V_OVERLOAD

PROTECT MultiCard™9
Re-triggerblockingisforthisinputlimitedtoonly5seconds,followinganyotherfogrelease.
Input 3isintendedforconnectiontoseismicdetectors,glassbreak,and/ordetectorsthatdetectintroduction
of gas into the ATM machine.
Ifitisactivated,itwillreapreselectedprotectionshot,todeteranyonefrombreakingtheATMbybrute
force,orbyintroductionofair/gasmixtobedetonated.
Therearenolimitstothenumberofsuchshotspossible(besideslimitsonuidcontent).
Thisinputisxed“normallyclosed”(activateswhenNOvoltageisapplied).
Possiblesettingsare:
Possiblesettingsare:
Re-triggerblockingisforthisinputlimitedtoonly5seconds,followinganyfogrelease.
The third trigger methodisintendedfortheeventthattheATMdoorisforcedopen.
Inthiscasealargeamountofinitialfogmayberequiredtollthepremises,andaseriesofpulsesmaybe
requiredtokeepthepremiseslleduntilsecuritypersonnelarrives.
Thethirdtriggermethodiscontrolledentirelybyinputsandsettingsonthemainboardlikeinanyotherfog
protection application without the use of a MultiCard.
Retriggerblockingisforthisinputlimitedto30seconds,followinganyfogrelease.
Please note that uid warning levelwillcorrespondtothefogsettingsonthemainboard!
Output 1isinthismodeadedicated“foghasbeenactivated”output,thatwillactivate(close)whenthefogis
released.Itwillstayactivated(closed)until“Disable”onthemainboardhasbeenactivated.
Thiswillindicatetostaffweatherthefogprotectionsystemwasactivatedornot.
Note:the“fog”relayoutputonthemainboardwillstillindicatewhenfogisactive,butwillreleaseoncefog
production stops again.
Outputs 2 to 9signalvariousfaultconditionsonseparateoutputs.
Seelistabove.
Do NOT rely solely on the fault indicating outputs on the MultiCard.
Fault, Fluid and Fog outputs on fog cannon mainboard should still be monitored for activity.
Please note that all trigger inputs are edge triggeredandthatre-triggeringafterafogreleasedependson
signals,returningtotheirnormallevel(closed)beforeagainbeingactivated(opened).
Fog volume
Dip setting
Dip 7 & 8
0,0
1,0
0,1
1,1
Shot type
5sturbo
10sturbo
20s normal
40s normal
85 m3
170 m3
290 m3
540 m3
Fog volume
Dip setting
Dip 9 & 10
0,0
1,0
0,1
1,1
Shot type
20s normal
40s normal
60s normal
30sturbo
290 m3
540 m3
700 m3
600 m3

PROTECT MultiCard™
10
6.3. ATM protection mode on PROTECT 1100i with separated fault outputs
Softwarerequirement,fogcannon:Softwareversion2.60orhigher.
Softwarerequirement,MultiCard:Softwareversion1.04orhigher.
Devicerequirements:ThisprogramisspeciallydesignedforPROTECT 1100i ONLY!
Attemptstousethisfeatureonothermachinesmayresultinunpredictedbehavior.
Dipswitchsettings:
1
0
2
1
3
0
4
0
5
0
6
0
7
Fog 2
8
Fog 2
9
Fog 3
10
Fog 3
Terminal “V+”iscurrentlynotused,andshouldbeleftunconnected.
ThisprogramfunctionalityhasbeenspeciallytailoredforprotectionofATMmachines.
Itcombinesthreedifferenttriggermethods,withindividualfogsettings.
Input 2 is intended for connection to detectors that detect attempts to manipulate the ATM shutter.
Ifitisactivated,itwillreapreselectedwarning shot to deter anyone from manipulating the shutter
mechanism.
Alimitofmaximum3shotsispossible.ThiswillberesetbyDisablesignalonthemainboard.
Aminimumbreakof5minutes(blockingtimer)betweensuch“warningactivations”isrequired.
ThisfeatureistolimittheamountofFogFluidthatmaybewastedduetothistypeofmanipulation.
Thisinputisxed“normallyclosed”(activateswhenNOvoltageisapplied).
Inputs functionality:
IN-SS Activates“Blockingmode”whenconnectedtogndonmainboard.
IN-2 ATMshuttermanipulation(normallyclosed)
IN-3 Seismic,glassbreakand/orgassensor(normallyclosed)
IN-4 Nofunction
Outputs functionality:
OUT-1 Foghasbeenactivated(willstaycloseduntilDisableisactivatedonmainboard)
OUT-2 E1_MAINS_VOLTAGE_LOST
OUT-3 E3_FIRE_ALARM_ACTIVEorE16_PANNIC_NOT_RELEASED
OUT-4 E4_BATTERY_VOLTAGE_LOWorE5_BAT_CHARGE_TIMEOUTorE6_BAT_LOADTEST_FAIL
OUT-5 E7_BOARD_TEMP_HIGHorE8_BOARD_TEMP_LOWorE14_BAT_TEST_CIRC_FAIL
OUT-6 E9_TEMP_TERM_HIGH
OUT-7 E10_TEMP_TERM_LOW
OUT-8 E12_PUMP_TIMEOUT
OUT-9 E13_AUX_12V_OVERLOAD

PROTECT MultiCard™11
Re-triggerblockingisforthisinputlimitedtoonly5seconds,followinganyotherfogrelease.
Theshortfogtimesindicatedareminimumguidelinesonly.Actualfogvolumemaybelargerthanindicated.
Input 3isintendedforconnectiontoseismicdetectors,glassbreak,and/ordetectorsthatdetectintroduction
of gas into the ATM machine.
Ifitisactivated,itwillreapreselectedprotectionshottodeteranyonefrombreakingtheATMbybrute
force,orbyintroductionofair/gasmixtobedetonated.
Therearenolimitstothenumberofsuchshotspossible(besideslimitsonuidcontent).
Thisinputisxed“normallyclosed”(activateswhenNOvoltageisapplied).
Possiblesettingsare:
Possiblesettingsare:
Retriggerblockingisforthisinputlimitedtoonly5seconds,followinganyfogrelease.
The third trigger methodisintendedfortheeventthattheATMdoorisforcedopen.
Inthiscasealargeamountofinitialfogmayberequiredtollthepremises,andaseriesofpulsesmaybe
requiredtokeepthepremiseslleduntilsecuritypersonnelarrives.
ThethirdtriggermethodiscontrolledentirelybyinputsandsettingsonthemainboardlikeinanyotherFog
protection application without the use of a MultiCard.
Re-triggerblockingisforthisinputlimitedto30seconds,followinganyfogrelease.
Please note that uid warning levelwillcorrespondtothefogsettingsonthemainboard!
Outputs 2 to 9signalvariousfaultconditionsonseparateoutputs.
Seelistabove.
Do NOT rely solely on the fault indicating outputs on the MultiCard.
Fault, Fluid and Fog outputs on fog cannon mainboard should still be monitored for activity.
Please note that all trigger inputs are edge triggeredandthatre-triggeringafterafogreleasedependson
signals,returningtotheirnormallevel(closed)beforeagainbeingactivated(opened).
Fog volume*
Dip setting
Dip 7 & 8
0,0
1,0
0,1
1,1
Shot type
7s
15s
20s
30s
250 m3
500 m3
687 m3
875 m3
Fog volume*
Dip setting
Dip 9 & 10
0,0
1,0
0,1
1,1
Shot type
30s
45s
60s
60s + 4 min.
875 m3
1200 m3
1300 m3
1700 m3
*Pleasenotethatnumbersonfogsettingsandfogvolumesmaydifferslightlyonlowvoltagemodels(115V/127V).
*Pleasenotethatnumbersonfogsettingsandfogvolumesmaydifferslightlyonlowvoltagemodels(115V/127V).

PROTECT MultiCard™
12
6.4. ATM protection mode on PROTECT 2200i with separated fault outputs
Softwarerequirement,fogcannon:Softwareversion2.91orhigher.
Softwarerequirement,MultiCard:Softwareversion1.05orhigher.
Devicerequirements:ThisprogramisspeciallydesignedforPROTECT 2200i ONLY!
Attemptstousethisfeatureonothermachinesmayresultinunpredictedbehavior.
Dipswitchsettings:
1
1
2
1
3
0
4
0
5
0
6
0
7
Fog 2
8
Fog 2
9
Fog 3
10
Fog 3
Terminal “V+”iscurrentlynotused,andshouldbeleftunconnected.
ThisprogramfunctionalityhasbeenspeciallytailoredforprotectionofATMmachines.
Itcombinesthreedifferenttriggermethods,withindividualfogsettings.
Input 2 is intended for connection to detectors that detect attempts to manipulate the ATM shutter.
Ifitisactivated,itwillreapreselectedwarning shot to deter anyone from manipulating the shutter
mechanism.
Alimitofmaximum3shotsispossible.ThiswillberesetbyDisablesignalonthemainboard.
Aminimumbreakof5minutes(blockingtimer)betweensuch“warningactivations”isrequired.
ThisfeatureistolimittheamountofFogFluidthatmaybewastedduetothistypeofmanipulation.
Thisinputisxed“normallyclosed”(activateswhenNOvoltageisapplied).
Inputs functionality:
IN-SS Activates“Blockingmode”whenconnectedtogndonmainboard.
IN-2 ATMshuttermanipulation(normallyclosed)
IN-3 Seismic,glassbreakand/orgassensor(normallyclosed)
IN-4 Nofunction
Outputs functionality:
OUT-1 Foghasbeenactivated(willstaycloseduntilDisableisactivatedonmainboard)
OUT-2 E1_MAINS_VOLTAGE_LOST
OUT-3 E3_FIRE_ALARM_ACTIVEorE16_PANNIC_NOT_RELEASED
OUT-4 E4_BATTERY_VOLTAGE_LOWorE5_BAT_CHARGE_TIMEOUTorE6_BAT_LOADTEST_FAIL
OUT-5 E7_BOARD_TEMP_HIGHorE8_BOARD_TEMP_LOWorE14_BAT_TEST_CIRC_FAIL
OUT-6 E9_TEMP_TERM_HIGH
OUT-7 E10_TEMP_TERM_LOW
OUT-8 E12_PUMP_TIMEOUT
OUT-9 E13_AUX_12V_OVERLOAD

PROTECT MultiCard™13
Re-triggerblockingisforthisinputlimitedtoonly5seconds,followinganyotherfogrelease.
Theshortfogtimesindicatedareminimumguidelinesonly.Actualfogvolumemaybelargerthanindicated.
Input 3isintendedforconnectiontoseismicdetectors,glassbreak,and/ordetectorsthatdetectintroduction
of gas into the ATM machine.
Ifitisactivated,itwillreapreselectedprotectionshottodeteranyonefrombreakingtheATMbybrute
force,orbyintroductionofair/gasmixtobedetonated.
Therearenolimitstothenumberofsuchshotspossible(besideslimitsonuidcontent).
Thisinputisxed“normallyclosed”(activateswhenNOvoltageisapplied).
Possiblesettingsare:
Possiblesettingsare:
Retriggerblockingisforthisinputlimitedtoonly5seconds,followinganyfogrelease.
The third trigger methodisintendedfortheeventthattheATMdoorisforcedopen.
Inthiscasealargeamountofinitialfogmayberequiredtollthepremises,andaseriesofpulsesmaybe
requiredtokeepthepremiseslleduntilsecuritypersonnelarrives.
ThethirdtriggermethodiscontrolledentirelybyinputsandsettingsonthemainboardlikeinanyotherFog
protection application without the use of a MultiCard.
Re-triggerblockingisforthisinputlimitedto30seconds,followinganyfogrelease.
Please note that uid warning levelwillcorrespondtothefogsettingsonthemainboard!
Outputs 2 to 9signalvariousfaultconditionsonseparateoutputs.
Seelistabove.
Do NOT rely solely on the fault indicating outputs on the MultiCard.
Fault, Fluid and Fog outputs on fog cannon mainboard should still be monitored for activity.
Please note that all trigger inputs are edge triggeredandthatre-triggeringafterafogreleasedependson
signals,returningtotheirnormallevel(closed)beforeagainbeingactivated(opened).
Fog volume*
Dip setting
Dip 7 & 8
0,0
1,0
0,1
1,1
Shot type
5s
10s
20s
40s
225 m3
450 m3
900 m3
1800 m3
Fog volume*
Dip setting
Dip 9 & 10
0,0
1,0
0,1
1,1
Shot type
20s
40s
70s
60s + 10 min.
900 m3
1800 m3
2875 m3
3700 m3
*Pleasenotethatnumbersonfogsettingsandfogvolumesmaydifferslightlyonlowvoltagemodels(115V/127V).
*Pleasenotethatnumbersonfogsettingsandfogvolumesmaydifferslightlyonlowvoltagemodels(115V/127V).

PROTECT MultiCard™
14

PROTECT MultiCard™15

PROTECT MultiCard™
16
PROTECTA/Sistheworld’slargestsupplierandtheonlyproducerofFogCannoninScandinavia.
PROTECT is represented worldwide in 50 countries.
PROTECT A/S·HasselagerCentervej5·DK-8260VibyJ·Tel.:(+45)86721881·Fax:(+45)86721882·Mail:[email protected]
PROTECTGLOBAL.COM
Table of contents
Other Protect Security Sensor manuals
Popular Security Sensor manuals by other brands

Winland
Winland WaterBug WB-800 Installation & operation instructions

DINUY
DINUY DM KNT 002 quick start guide

Datasensing
Datasensing S3N-PR T5 Series manual

Cassida
Cassida QUATTRO user manual

Panasonic
Panasonic SF4B-F31G(V2) instruction manual

B.E.G.
B.E.G. LUXOMAT net PD4-M-DAA4G Installation and operating instruction