WARNING
TO AVOID RISK OF DAMAGE IN CASE OF WATER OVERHEATING, YOU MUST USE COPPER PIPES
TO MAKE THE CONNECTIONS BETWEEN THE TEMPERING TANK AND THE HOT WATER LOOP
KIT FOR PRE-HEATING OF DOMESTIC WATER, FOR BOTH THE INPUT AND OUTPUT OF THE
WATER LOOP ASSEMBLY.
F LO O R DR AIN
H OT W AT ER
IT IS V ER Y IM P O RT AN T T O
M A IN T AIN AN AS CE ND IN G
SL OP E O F 2 IN C HES PER
FO O T O N TH E P IP E C O NNECTING
TH E FUR NACE TO THE BU FFER TA N K
C OLD W ATE RSU PPLY T EM P ER IN G TA NK 210F /120LB S
O NE W A Y VA LV E
PR ESSURE G AGE
RELIE F VALVE
DR A IN VALVE M A IN W A TE R HEA TER
RELIEF VALVE
W AT ER LO OP
INLET
OUTLET
W AT ER L OO P
VALVE
SO LENOID
CONNECTION DIAGRAM FOR THE OPTIONAL HOT WATER LOOP KIT FOR PRE
DOMESTIC WATER
IT IS VERY IMPORTANT TO MAINTAIN AN ASCENDING SLOPE OF 2 INCHES PER FOOT
ON THE PIPE CONNECTING THE FURNACE TO THE TOP INLET ON THE BUFFER TANK.
THE BUFFER TANK USED MUST HAVE A CAPACITY OF 60 GALLONS.