IMPORTANT - STOP USE IMMEDIATELY
#10981 and #10974 3-Way SRL
PART NUMBERS AFFECTED:
STEP 1. DETERMINE DATE OF MANUFACTURE
STEP 2. REMOVE AFFECTED PRODUCT FROM SERVICE
PRODUCT RECALL
THERE HAVE BEEN NO ACCIDENTS OR INJURIES RELATED
TO THIS PRODUCT RECALL.
If the date of manufacture is prior to 3/2019 the product
must be immediately removed from service. Removal from
service is also required if the date of manufacture is un-
known. All aected product must be returned to Pure Safety
Group for repair. DO NOT ATTEMPT TO REPAIR THE UNIT.
This notice is intended to communicate product recall in-
formation regarding the Guardian Fall Protection and Web
Devices 3-Way Rescue and Retrieval self-retracting lifeline.
Under certain conditions, braking forces may cause gear mis-
alignment, potentially resulting in diminished rescue/retrieval
functionality.
Fig. A - Date of Manufacture Label
The recall affects all 3-Way SRLs manufactured prior to
March 2019. The recall includes the following part #s:
Guardian #10974 (50’) and #10981 (65’), and Web Devices
#0501312 (50’) and #0651312 (65’). Any and all custom or
private-labeled 3-Way SRLs are also affected.
**Please note, 3-Way SRLs are also sold in the following Arc-
O-Pod kit part #s: #20001, #20004.
PLEASE TAKE IMMEDIATE ACTION TO COMPLETE THE FOLLOWING STEPS:
10974
50’; 3/16” CABLE
Serial # Mfg. Date
90516 (Rev. B)