PW90 Manual Page 5 - Revision: 6-08-2023
WARNING! CONNECT TO POTABLE WATER SUPPLY. This system is to be used for water only
and is NOT intended for use where water is microbiologically unsafe or with water of
unknown quality without adequate disinfection before or after the system.
WARNING! TIP HAZARD. Dispenser could tip or fall causing serious injury if installed with a
base. Always install unit on a firm, flat, and level surface and secure unit to cabinet, wall, or
floor if needed and secure to the base, if applicable. Never place heavy items on top of unit
and never climb, stand, or hang on unit or storage cabinet to prevent injury and damage.
WARNING! UNIT IS HEAVY. TWO PERSON LIFT REQUIRED. Transport unit empty and always
use material handling equipment or two people with proper lifting technique to reduce injury
risk.
WARNING! STORE AND TRANSPORT UNIT EMPTY. ALWAYS SANITIZE BEFORE USE.
The unit must be completely drained before storing to avoid stagnation and reduce
microbiological contamination (potential bacterial growth). Always sanitize before use to
eliminate any potential microbiological contaminates.
CAUTION! INDOOR USE ONLY. Intended for Household Use. Never expose to direct
sunlight, heat sources, or ambient air temperature above 37°C (100°F) or below 2°C (35°F).
Install indoors and keep unit away from excessive humidity or rain. Never expose to freezing
temperatures. Ensure there is adequate clearance around the unit to allow refrigeration
system condenser to dissipate heat. Warmer environments require more clearance around
the unit. Minimum clearance around all surfaces of the machine is 2-inches. Installs where
the ambient temperature exceeds 27°C (80°F), require a minimum of 4-inches clearance for
proper heat dissipation and efficient operation.
CAUTION! USE A WATER PRESSURE REGULATOR. Pure Water Technology will not be
responsible for injury or damage caused by excessive water pressure. Input or feed pressure
must be 60 psi to 70 psi. Be aware of any potential pressure surges caused by
building/municipal pumping stations. Failure to comply will void all warranties. The
manufacturer accepts no liability for damage caused by excessive water pressure.
CAUTION! USE UV STABILIZED SUPPLY LINES. Feed the unit with a potable ambient or
cold-water supply only. Feed water over 37°C (100°F) can damage the treatment
components. Water block devices and external leak detectors are strongly recommended.
Locate the unit as close to the water supply and the electrical connections as possible.
Immediately isolate or close water supply valve and contact service representative if leak is
noticed.
WARNING! REFRIGERANT SYSTEM. This system is manufactured with 134A refrigerant.
Repairs to the refrigeration system must be performed by a certified refrigeration technician
only.
CAUTION! DO NOT PLACE HEAVY ITEM OR WATER CONTAINER ON TOP OF UNIT. Water
may leak into the electrical system causing a fire hazard. Heavy items may fall off causing
injury.
Contact Pure Water Technology for assistance or help finding an Authorized Service
Representative.