Pureit EXCELLA User manual

Welcome to the Pureit Family
Complete Germ Protection
REACH PUREIT AT
www.pureitwater.com
+632-5620091
+632-9498071


1
Congratulations!
Welcome to the Pureit Family!We thank you for the trust you have shown in our
product and we guarantee you that our product will live up to your expectations.
Pureit Excella is trusted by millions of users around the world for providing safe
drinking water for their loved ones.
Our product is developed by experts and is designed to give you water that is
completely protected from harmful germs. Pureit adheres to the toughest global
standards of some leading institutions.
If ever you need to get in touch with us for anything, please call us at
+632-5620091, +632-9498071.
We once again thank you for buying our product and we look forward to a long
and fruitful association with you.
Complete Germ Protection
World’s largest selling water puriers*
* Based on Unit shipment sales for 2012. Excludes pitchers and faucet mount system sales and includes only in-home point-of-use drinking water
treatment systems.

2
CONTENTS
Pureit Excella Advantages........................................................................ 3
Getting to Know Your Pureit Excella....................................................... 4
How Pureit Excella Works ...................................................................... 5
Setting up Pureit Excella ......................................................................... 6
Ordering and Changing the Germkill Kit ................................................. 8
Cleaning & Maintenance of Pureit Excella ..............................................16
Dos & Don’ts.........................................................................................23
FAQs.....................................................................................................24
Technical Specications for Pureit Excella ............................................. 25

3
PUREIT EXCELLA ADVANTAGES
No continuous tap water
No harmful bacteria, virus & parasites
No chlorine taste
No boiling
No electricity
Food grade plastic
Auto Shut-off
No undesirable odour
Natural tasting water
Great after sales service
Advanced Alert System
Strong and durable
No expensive bottled water
Programmed Germkill Technology
Easy Maintainence
No plumbing

4
GETTING TO KNOWYOUR PUREIT EXCELLA
Germkill Life Indicator Cover
Sediment Filter
Top Lid
Top Cover
Top Chamber
Carbon Polisher
Microber Mesh
Tap
Microcharged Membrane Assembly
Transparent Chamber
Pedestal
Germkill Life Indicator
Cleansing Collection Chamber
Germkill Processor
Batching Chamber

5
HOW PUREIT EXCELLA WORKS
Removes
harmful parasites and
chlorine, making the
water clear, odorless
and natural tasting.
C
a
r
b
o
n
P
o
l
i
s
h
e
r
Puries
the water again
and removes harmful
parasites giving the
assurance of double
protection.
M
i
c
r
o
c
h
a
r
g
e
d
M
e
m
b
r
a
n
e
Uses
PGT - ‘Programmed
Germkill Technology’
to target and remove
harmful viruses and
bacteria.
G
e
r
m
k
i
l
l
P
r
o
c
e
s
s
o
r
Removes
precipitated
metallic
impurities.
M
i
c
r
o
f
b
e
r
M
e
s
h
Removes
visible dirt
S
e
d
i
m
e
n
t
F
i
l
t
e
r

6
SETTING UP PUREIT EXCELLA
Remove the Transparent Chamber with the
pedestal and keep it aside.
Discard the plastic lm from it.
Remove the Cleansing Collection Chamber,
Top Chamber and the Top Lid and keep it aside.
Discard the thermocol from the Top Chamber.
Wash hands thoroughly. Remove the
Microcharged Membrane Assembly from
tamper proof pouch kept inside the
Cleansing Collection Chamber.
Open the box. Remove the Top Cover and keep it
aside. Remove and discard the thermocol.
There is a bellow pump in the Top Chamber. Keep it in a safe place as you will
need it later for cleaning.
1
3
2
4

7
SETTING UP PUREIT EXCELLA
Place the Top Chamber on the Cleansing Collection
Chamber, then place Sediment Filter in the Top
Cover and place it on the Top Chamber.
Pour in water till the top of the Top Chamber and drain
out all the water that collects in the Transparent Chamber
for rst two cycles. Place the lid on the Top Cover. Pureit
is now ready to use from third cycle onwards.
7 8
After tting the Microcharged Membrane Assembly to the Cleansing Collection Chamber,
do not rest the assembly on a at surface.
Please note that the rst cycle will not give full 9L of water in the Transparent Chamber
since some water gets stored in the Cleansing Collection Chamber and the Top Chamber.
Now place the Cleansing Collection Chamber
on the Transparent Chamber.
Insert the Microcharged Membrane Assembly at
the base of the Cleansing Collection Chamber.
Twist in clockwise direction to t.
5 6

8
ORDERING AND CHANGING THE GERMKILL KIT
When Indicator shows white or partially
red, the Germkill Kit is working and it’s safe
to use.
When Indicator shows mostly red, the
Germkill Kit is nearing its end of life
and its time to buy a new Germkill Kit.
When Indicator shows fully red, the
Germkill Kit has exhausted and it is time
to replace it.
Safe to use
Time to buy a
new Germkill Kit
Time to replace
There is an Auto Shut-off overow port provided on the Germkill Life Indicator Cover.
When the Germkill Life Indicator is red, you might observe overow from this port. Please
replace the Germkill Kit. Do not pour any more water in the Top Chamber to avoid further
spillage.

9
There are multiple Pureit Germkill Kit(s) available. Please buy the one that is recommended
for your Pureit model.
ORDERING AND CHANGING THE GERMKILL KIT
Microcharged Membrane Germkill Processor Carbon Polisher
You can buy a Germkill Kit in any
of the following ways
The Germkill Kit consists of 3 parts
www.pureitwater.com
Log on to locate your nearest dealer
Visiting your nearest Pureit dealer
+632-5620091
+632-9498071
Call Pureit helpline to
locate your nearest dealer

10
Slightly pull the Germkill Life Indicator Cover
upwards and remove it from the purier.
Empty water from the Cleansing Collection
Chamber completely.
Remove the Top Cover with the Sediment Filter.
Remove Top Chamber and empty it completely.
Please empty the water from the Top Chamber, Cleansing Collection Chamber
and the Transparent Chamber completely before replacing the Germkill Kit.
Always keep Microcharged Membrane on a clean surface.
1 2
3
Remove the Microcharged Membrane Assembly by twisting it in
the anti-clockwise direction and keep the Microcharged Membrane
and the Cleansing Collection Chamber on a clean surface.
4
ORDERING AND CHANGING THE GERMKILL KIT

11
Remove it from the purier.
Remove the Carbon Polisher by rotating it in the
anti-clockwise direction.
Rotate the Microbre Mesh in the
anti-clockwise direction.The Carbon Polisher
will come out along with it.
ORDERING AND CHANGING THE GERMKILL KIT
Discard the old Carbon Polisher.
5 6
7 8
OLD

12
Wash the Microber Mesh
under a jet of clean water.
ORDERING AND CHANGING THE GERMKILL KIT
9
Insert the new Carbon Polisher.
Rotate clockwise to t.
10
11
NEW
12
Replace the Microber Mesh and the Carbon Polisher
Assembly in the purier. Rotate clockwise to t.

13
Hold the base and rotate the Microcharged Membrane in
clockwise direction to t. Ensure tight tment.
17
Hold the base and rotate the
Microcharged Membrane in the
anti-clockwise direction.
Discard the old Microcharged Membrane
and insert the new Microcharged Membrane.
Remove the Microcharged
Membrane along with its base,
from the holder. Keep the holder
on a clean surface.
ORDERING AND CHANGING THE GERMKILL KIT
14 15
16
Wash hands thoroughly, take the
Microcharged Membrane (removed in
Step 4), rotate the base in anti-clockwise
direction.
13
Please empty the water from the Top Chamber, Cleansing Collection Chamber and the
Transparent Chamber completely before replacing the Germkill Kit.
Always keep Microcharged Membrane on a clean surface.

14
Replace the Microcharged Membrane along with
the base in the Microcharged Membrane holder
and rotate the base in clockwise direction to t.
ORDERING AND CHANGING THE GERMKILL KIT
18 19
Insert the Microcharged Membrane
Assembly at the base of the Cleansing
Collection Chamber. Rotate clockwise to t.
21
Replace the Cleansing Collection Chamber on the
Transparent Chamber.
20
Turn the Germkill Processor in
anti-clockwise direction to remove and
discard the old Germkill Processor.

15
Place the Germkill Life Indicator Cover in the
grooves provided on the Cleansing Collection
Chamber and push it downwards to t.
Fill the Top Chamber and drain out
all the water that collects in the Transparent Chamber
for rst two cycles. Pureit is now ready to use
from third cycle onwards.
Insert the new Germkill Processor and
rotate in the clockwise direction to t.
Ensure tight tment.
ORDERING AND CHANGING THE GERMKILL KIT
22 23
25
Place the Top Chamber on the
Cleansing Collection Chamber.
Place the Top Cover with the Sediment Filter.
24

16
Remove Top Lid and clean it with tap water. Leave it to
drip dry.
Remove the Sediment Filter from the Top Cover and
clean it by tapping it under a stream of clean water to
dislodge dirt and grime.
CLEANING & MAINTENANCE OF PUREIT EXCELLA
1 2
3 4
Do not clean the hole in the Top Chamber with sharp objects.
Rinse the Top Chamber with clean water and leave it to
‘drip dry’ in a clean place.
Remove Top Cover and clean it with tap water. Leave it
to drip dry.

17
Wash hands thoroughly. Rotate the Microcharged Mem-
brane Assembly in anti-clockwise direction to remove.
Keep it aside in a clean place.
Rotate the Germkill Processor in the
anti-clockwise direction to remove and keep it in a safe
place.
CLEANING & MAINTENANCE OF PUREIT EXCELLA
8
6
Do not remove the Microcharged Membrane Assembly without emptying water from the
Cleansing Collection Chamber.
Empty the water from the
Cleansing Collection Chamber.
7
Slightly pull the Germkill Life Indicator Cover upwards
and remove it from the purier.
5

18
Wash the Microber Mesh under
a jet of water.
CLEANING & MAINTENANCE OF PUREIT EXCELLA
12
Rotate the Carbon Polisher in the
anti-clockwise direction to remove.
10
Wash the Carbon Polisher in running water
by gently scrubbing it with hands. Do not use
detergent or scrubber.
11
9
Rotate the Microber Mesh in the anti-clockwise
direction to remove.The Carbon Polisher will come out
along with it.
Other manuals for EXCELLA
1
Table of contents
Other Pureit Water Dispenser manuals
Popular Water Dispenser manuals by other brands

Innova
Innova CEV+ Installation, use and maintenance

Kenmore
Kenmore 625.383000 Use & care guide

Kinetico
Kinetico Premier Compact Installation and user manual

CASO DESIGN
CASO DESIGN 11862 Original operating manual

Global Industrial
Global Industrial 761217 user manual

AquaScape
AquaScape 77005 Instructions & maintenance