manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Pyle
  6. •
  7. Amplifier
  8. •
  9. Pyle PQA2100 User manual

Pyle PQA2100 User manual

Professional Power Amplifier
PQA 2100
PQA 3100
PQA 4100
PQA 5100
www.pyleaudio.com
B
B
B
B
Designed and engineered in U.S.A Designed and engineered in U.S.A
Designed and engineered in U.S.A
Designed and engineered in U.S.A
PQA5100
2550+2550wrms
1200+1200w
600+600w
2400+2400w
>85dB
>85dB >90dB
>70dB
>250 >250 >250
30v/μs
<140W <300W <300W
482x314x88mm
8kg 9.5kg 11.5kg
。
。
。
。
。
。
Installation guidelines
DO NOT use these amplifiers in damp or high humidity environments.
Do not use outdoors or anywhere where liquids could fall or splash onto the amplifier.
Ensure the amp is adequately ventilated, with free airflow to the front and rear panels.
Keep away from other heat sources. If the amps are mounted in a rack with other amps,
ensure there is adequate cool air flow front and rear. Note that air is drawn in through
the back panel, and exhausted through the front panel.
NEVER cover the amplifiers, as they may overheat.
PQA power amplifiers are designed to fit standard 19 racks, with a 2U height
and 17 depth. We recommend the use of rear rack supports, especially if the rack is to
be mobile. Use shake proof washers or thread lock adhesive to prevent mounting bolts
becoming loose in transit.
Ensure that the AC power supply is correct for your amplifier. The required AC supply
is stated on the rear panel next to the AC power input.
Ensure that you use the correct type of mains lead for your equipment and country.
This must be free from damage and easily accessible during use.
1550+1550wrms
760+760w
380+380w
1520+1520w
1050+1050wrms
460+460w
230+230w
920+920w
Model
PQA4100
PQA3100
PQA2100
2050+2050wrms
1000+1000w
500+500w
2000+2000w
10Hz-50KHz -1.5dB
21dB/9V
20K OHMS
>90dB
>70dB >70dB >70dB
>250
30v/μs30v/μs30v/μs
Variable Speed Fan
<300W
AC 115V-230V/50-60Hz
10.5kg
2 O H MS
THD
PQA PQA
www.pyleaudio.com www.pyleaudio.com
h
Short circuit,Current limiter,T ermal cut off,Slow Start,
Limiter,AC line fuse, DC fault,Power up/down transients
OVERVIEW
It is well-known the PQA series professional amplifier is designed by the
specialist who has full experience and new model equipment. To raise
reliability of the amplifier, PQA series professional amplifier has been
installed with short distance cooling unit,
high-speeding and consistency to increase the life of the power parts.They
all have adopted mature and reliable circuit with SMT technology.
The conventional amplifier applies tunnel-model cooling system, this kind
of system has long distance for heat dissipation,the hot air is distributed
with difficulty, and theradiator is very hot at the top, but too cool at the
bottom, the temperature difference goes between 2 0℃-4 0℃,those system
produces temperature difference easily in the power parts, the electric
current is high in hot parts, which results in its damage and reduces the
using-life and reliability.
PQA series amplifiers has full-protection, including:
Soft start function to prevent wave shock at power-on.
Delay function for prevent shock at switch power on.
DC protection.
Over-electric current protection.
Cut-wave protection.
Over heat protection.
ATTENTION
Never put any parts on the top of the amplifier.
Using fixed power socket that must be has enough capacity to prove power.
Never switch the power on and off continuously at the same time.
Donruction in the air vent of front panel.
Input stereo level can be adjust by own gain mixer, in bridge-model connection,
the adjustment will adjust by CHA channel mixer.
The output connector have 3 kind model, tie-model, phone model and professional
speakon connector for connecting.
When using stereo, bridge, mono function, the connect model must be same than
model switch selected.
When output high-power signal continuously, the amplifier should be has speed-
up in the cooling fan, it may be have low noise produce in this equipment, it is
normally.
The general gain of the amplifier can be adjust by gain knob, the input level
have 0 .7 7V, 1 .4 V, full-power out and fixed 2 6dB gain 3 band should be selected.
Donr vent of rear panel.
When clear-up the cover of the equipment, you must be power off and loose the
power Plug using dry-cloth to clear, never using and solvent that have corrosive
to clear.
If have problem happened, power down immediately, and contact with dealer.
Designed and engineered in U.S.A
Designed and engineered in U.S.A
Designed and engineered in U.S.A
Designed and engineered in U.S.A
8. Bridge mode(PQA2100 doest have bridge mode)
As the work is bridge mode, CH A output+connector is the Bridge connector +;
while CH B+ connector is the Bridge connector -.
PQA PQA
www.pyleaudio.com www.pyleaudio.com
1
2
8
3
34
4
5
6
7
6
2
MODE
ST BR
Rear Panel
B
Page5
Service
All the products are thoroughly examined and tested
before leaving the factory, and if used correctly will give you
many years of excellent service. However,
if a problem arises, proceed as follows:
(A) contact the retailer from whom the unit was purchased and
describe the symptoms of the fault.
(B) if the retailer cannot help, return the equipment to the
national distributor for your country. Use the original packaging
to protect the product from damage. Include a note with the
equipment stating your name and address, details of the
problems, date code and date and place of purchase.
FAULT PROBLEM SOLUTIONS
No sound
(power
LED off)
AC supply not connected or
switched off
Blown fuse
Check AC connections and switches
Check and replace fuses at plug and IEC
socket. USE ONLY SAME TYPE AND RATING!
NO sound
(Power
LED on)
No input,
or input too low
Level controls set too low
Speakers faulty or
not connected
Check input is connected, and LED
Increase level controls
Check speakers and speaker connections
Hum or
buzz is
audible
Noise from AC supply is being
picked up in the signal path
There is an earth problem
Use good quality, shielded signal cables and
ensure they are kept away from AC power cables
and other AC powered equipment
Use a mains tester to ensure the AC outlet
has a good earth. Power connected equipment(e.g mixer
and amp) from the same AC outlet where possible.
Distortion
is audible
Excessive signal level
somewhere in signal chain.
Damaged or poor quality
cables
Sound cuts
out or is I
ntermittent
Damaged or poor quality
cables or connectors,
connectors not properly
inserted, amp overheating
Use only high quality cables of the appropriate type,
protect them from damage and regularly
check connections.
Use the LED to ensure the AC outlet has a good earth.
Power connected equipment from the same AC outlet
where possible
Check all cables and connections, refer to above
sections regarding distortion and temp warning light
PQA
www.pyleaudio.com

This manual suits for next models

3

Other Pyle Amplifier manuals

Pyle PCAU46BA User manual

Pyle

Pyle PCAU46BA User manual

Pyle P2203ABTU User manual

Pyle

Pyle P2203ABTU User manual

Pyle PLMR77U User manual

Pyle

Pyle PLMR77U User manual

Pyle PCM30A User manual

Pyle

Pyle PCM30A User manual

Pyle PT4601AIU User manual

Pyle

Pyle PT4601AIU User manual

Pyle PFA320BT User manual

Pyle

Pyle PFA320BT User manual

Pyle PDA63BT User manual

Pyle

Pyle PDA63BT User manual

Pyle PTA1000 User manual

Pyle

Pyle PTA1000 User manual

Pyle PLMRC300X2 User manual

Pyle

Pyle PLMRC300X2 User manual

Pyle PT530A User manual

Pyle

Pyle PT530A User manual

Pyle PWA12 User manual

Pyle

Pyle PWA12 User manual

Pyle PWMA-850 User manual

Pyle

Pyle PWMA-850 User manual

Pyle PLMRC500X1 User manual

Pyle

Pyle PLMRC500X1 User manual

Pyle PFA560BT User manual

Pyle

Pyle PFA560BT User manual

Pyle PDA8BUWM User manual

Pyle

Pyle PDA8BUWM User manual

Pyle PMXAKB2000 User manual

Pyle

Pyle PMXAKB2000 User manual

Pyle PLMRM4BTA User manual

Pyle

Pyle PLMRM4BTA User manual

Pyle PHE1AW User manual

Pyle

Pyle PHE1AW User manual

Pyle PT250BA User manual

Pyle

Pyle PT250BA User manual

Pyle PHA211 User manual

Pyle

Pyle PHA211 User manual

Pyle PT506BT User manual

Pyle

Pyle PT506BT User manual

Pyle PT8050CH User manual

Pyle

Pyle PT8050CH User manual

Pyle PDA46BT User manual

Pyle

Pyle PDA46BT User manual

Pyle Blue Series User manual

Pyle

Pyle Blue Series User manual

Popular Amplifier manuals by other brands

Diamond D3 owner's guide

Diamond

Diamond D3 owner's guide

GSS PTAF 2000 installation guide

GSS

GSS PTAF 2000 installation guide

Empress Effects nebulus user manual

Empress Effects

Empress Effects nebulus user manual

OM POWER OM3500 HF instruction manual

OM POWER

OM POWER OM3500 HF instruction manual

MYERS MI-120S Operation manual

MYERS

MYERS MI-120S Operation manual

Mesa/Boogie Three Channel Dual & Triple Rectifier Solo... owner's manual

Mesa/Boogie

Mesa/Boogie Three Channel Dual & Triple Rectifier Solo... owner's manual

Kingrex T20 user manual

Kingrex

Kingrex T20 user manual

Novus NR2110-R manual

Novus

Novus NR2110-R manual

Dared VP-845LE user manual

Dared

Dared VP-845LE user manual

Orion 2100 HCCA installation manual

Orion

Orion 2100 HCCA installation manual

Hegel H4A user manual

Hegel

Hegel H4A user manual

MBL 9007 owner's manual

MBL

MBL 9007 owner's manual

Crestron MP-AMP30 Operations & installation guide

Crestron

Crestron MP-AMP30 Operations & installation guide

Academy Dragster DA-4860DSP user manual

Academy Dragster

Academy Dragster DA-4860DSP user manual

Peavey Backstage Chorus 208 quick start guide

Peavey

Peavey Backstage Chorus 208 quick start guide

Burster 9250 Operation manual

Burster

Burster 9250 Operation manual

TDG AUDIO DA-1260 owner's manual

TDG AUDIO

TDG AUDIO DA-1260 owner's manual

Coda 8M Operation manual

Coda

Coda 8M Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.