CHILLER UNIT
INSTALLATION GUIDE
& WARRANTY INFORMATION
Before you Begin
1. Check the mains water pressure. The pressure must
not be below 1.5 BAR (22 psi) or above 5 BAR (73 psi),
measured during a low demand period – (mid-morning or
mid-aernoon).
If the pressure exceeds 5 BAR a pressure reducing valve
must be installed in the cold mains supply to protect both
the boiler and the water lter housing. A suitable pressure
reducing valve can be purchased at www.grldirect.co.uk/
franke
2. The unit must be installed in a frost free environment.
3. Ensure that the cabinet is well venlated. If in doubt it is
advisable to improve the circulaon of air by drilling some
holes in the top and boom of the rear panel.
4. Be careful when making the connecons to the chiller.
Do not be tempted to over-ghten the connecons. It is
only necessary to rmly hand ghten the nuts using the
patented NutRunna® plasc ghtening devices provided to
make a secure waterght seal.
5. Shut o the mains water supply.
6. Switch o the mains electricity supply at the socket.
7. Covering the chiller will cause it to overheat, aecng its
performance and potenally causing it to shut down.
8. Ensure that the chiller is seated on a at surface, well
venlated and not in direct sunlight.
9. A kitchen base unit not less than 800mm wide, good
venlaon within the cabinet to allow cooling of the chiller
unit.
Where possible you should provide a vent in the base and
one near the top of the cabinet to allow air to ow. You
must provide a 75mm air gap on all sides of the cooler unit.
Introducon
Thank you for purchasing this QETTLE Chiller system. Correctly installed and properly maintained in
accordance with the following instrucons, it will provide you with reliable service for many years. This
guide explains how to install a new water chiller system.
Warranty
This product is a water chilling device intended for domesc use only. The water supply pressure must be
between minimum 1.5 BAR (22 psi) maximum 5 BAR (73 psi).
Descripon Value Unit
Dimensions 180w x 320h
x 370d
mm
Load 10 Amps
Voltage 230 Volts
Power
(Compressor)
160 Was
Min Water
Pressure
1.5 Bar
Max Water
Pressure
5 Bar
Cooling Time 20 Mins
Recovery
Time
15 Mins
Tank
Capacity
1.2 Litres
Dispensing
Temperature
3-6 ˚C
Dispensing
Capacity at
4 ˚C - 10 ˚C
0.9 Litres
Weight 12 Kg
Refrigerant R-134A N/A
Decibel Rang 38 dB
Component List
1. Water Chiller (x1)
2. Inlet Hose - Red idencaon (x1)
3. Outlet Hose - Blue idencaon (x1)
4. 3/8” Straight JG Push Fit Connector (x2)
5. 3/8”-1/4” Straight JG Push Fit
Connector (x2)
Installing the Chiller
Please Note: This chiller is supplied with xtures and ngs that are compable with most kitchen tap appliances.
However, should you nd any of the ngs provided are not compable with your tap, please contact us with details
of your tap’s brand and model—and we will endeavour to help you. For ease of installaon the chiller connecons
and the exible hoses are colour coded: Blue - Water outlet. Red - Water inlet.
1. IMPORTANT Do not plug the chiller into the power supply unl the installaon process has been completed.
2. Remove the protecve caps from the three connecons on the top of the chiller.
3. Place the chiller in an upright posion on a at surface inside the cabinet with the connecons to the top.
4. See below photo — Take the water inlet hose (red indicator) and screw onto chiller inlet (red arrow). Hand ghten
using the aached NutRunna® sucient to make a waterght seal. Do not overghten.
5. See below photo — Take the water outlet hose, (blue indicator) and screw onto chiller outlet (blue arrow). Hand
ghten using the aached NutRunna® sucient to make a waterght seal. Do not overghten.
6. See below photo —Take the free end of the inlet hose and connect to your lter system using either one of the
connectors that are supplied, depending whether your system uses 1/4” diameter or 3/8” diameter exible tubing.
7. See below photos—Take the free end of the outlet hose and connect to your tap inlet using either one of the
connectors that are supplied, depending whether your system uses 1/4” diameter or 3/8” diameter exible tubing.
8. Turn on the water supply.
9. Operate the chilled water funcon on your tap for 3 minutes to ush the system.
10. Turn the tap o and check the connecons for leaks.
11. Plug the chiller into the mains electricity supply socket.
12. Switch the chiller to the “ON” posion. Check the top LED (plug icon) on the chiller’s front cover turns green to
indicate power is on. The lower LED (mug icon on chiller’s cover) will turn red to indicate the chiller is in operaon.
13. Allow approximately 20 minutes for the chiller to reach full operang temperature, indicated by the lower LED
turning green.
Components 2 & 3 Components 4 & 5
3/8”—1/4”
Straight JG Push-Fit
Connector
QUANTITY— 2
3/8”—3/8”
Straight JG Push-Fit
Connector
QUANTITY—2
Aaching the water inlet hose (red) Aaching the water outlet hose (blue)
Guarantee
This QETTLE product carries a 3 year warranty against material and manufacturing defects. The warranty will be valid
from the date of purchase as shown on the sales invoice. Please keep the invoice for your records. This appliance is
intended for domesc use only. The warranty does not apply to products installed outside a domesc environment.
Warranty
What is covered by the QETTLE guarantee?
• The repair or replacement of all or part of your system if your system is found to be defecve due to faulty
materials or manufacture within 3 years of purchase at QETTLE’s discreon.
• If any part is no longer available, or out of manufacture, QETTLE reserve the right to replace it with a suitable
alternave.
• Terms and condions of the QETTLE 3 year guarantee.
• The guarantee is valid for the UK and Republic of Ireland.
• The guarantee becomes eecve at the date of purchase or at the date of delivery if this is later. Proof of
purchase is required under the terms of the guarantee.
• The guarantee provides benets in addion to your statutory consumer rights.
QETTLE does not guarantee the repair or replacement of a product that has failed for any of the following reasons:
• Faulty installaon, repairs or alteraons not in accordance with the installaon guide.
• Normal wear and tear.
• Accidental damage or faults caused by negligent use or care; misuse; neglect; careless operaon and failure to
use the system in accordance with the QETTLE operang guidelines.
• Failures of, or failures caused by, parts not supplied with the QETTLE system.
Aer Sales Service
QETTLE
Old Winery Business Park
Chapel Street
Cawston, Norfolk
NR10 4FE
+44 (0) 1603 875 464
support@qele.com
www.qele.com
The QETTLE chiller is compliant in accordance with the following direcves: 2006/95/EC Low Voltage Direcve 2011/65/EU RoHS Direcve 2009/125/EC Eco Design
Direcve Protecon Level: IP20 The QETTLE chiller conforms to the requirements of the relevant EU guidelines. The symbol on the product or on its packaging indicates
that this product may not be treated as household waste. Instead it shall be handed over to the applicable collecon point for the recycling of electrical and electronic
equipment. By ensuring this product is disposed of correctly, you will help prevent potenal negave consequences for the environment and human health, which could
otherwise be caused by inappropriate waste handling of this product. For more detailed informaon about recycling of this product, please contact your local city oce,
your household waste disposal service or the shop where you purchased the product.
DECLARATION OF CONFORMITY
The QETTLE Chiller is a product of Greg Rowe Ltd. QETTLE is a trading name of Greg Rowe Limited.
Part No. 996373

Popular Chiller manuals by other brands

Bromic Heating Medifridge MED0220GD instruction manual

Bromic Heating

Bromic Heating Medifridge MED0220GD instruction manual

RHOSS Compact-Y SM THAEY 122 Instructions for use

RHOSS

RHOSS Compact-Y SM THAEY 122 Instructions for use

Hyco Sapphire SAPUC1 Product instruction manual

Hyco

Hyco Sapphire SAPUC1 Product instruction manual

CLIVET WSH-XSC3 Installation and operating manual

CLIVET

CLIVET WSH-XSC3 Installation and operating manual

Borg & Overstrom u1 Install & operation guide

Borg & Overstrom

Borg & Overstrom u1 Install & operation guide

Sammic 3 instruction manual

Sammic

Sammic 3 instruction manual

KREYER Chilly operating instructions

KREYER

KREYER Chilly operating instructions

Trane BAYSQRD001 Installer's guide

Trane

Trane BAYSQRD001 Installer's guide

SMC Networks HRZ002-WS-F Operation manual

SMC Networks

SMC Networks HRZ002-WS-F Operation manual

MAXA A68 Installation and operation manual

MAXA

MAXA A68 Installation and operation manual

Carrier AquaForce 30XQ0502 Installation, operation & maintenance instructions

Carrier

Carrier AquaForce 30XQ0502 Installation, operation & maintenance instructions

Trane 4YCZ5036F1070B Installation and operation manual

Trane

Trane 4YCZ5036F1070B Installation and operation manual

MP Systems V Series Installation operation & maintenance

MP Systems

MP Systems V Series Installation operation & maintenance

Aquacal TropiCool TC500 Operation manual

Aquacal

Aquacal TropiCool TC500 Operation manual

Hydrofarm ACTIVE AQUA AACH100 instruction manual

Hydrofarm

Hydrofarm ACTIVE AQUA AACH100 instruction manual

IV Produkt Envicooler Operation and maintenance instructions

IV Produkt

IV Produkt Envicooler Operation and maintenance instructions

York MILLENNIUM YCAL0043SC manual

York

York MILLENNIUM YCAL0043SC manual

Carrier 30KAV-ZE Series Installation, operation and maintenance instructions

Carrier

Carrier 30KAV-ZE Series Installation, operation and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.