Plug and Play Fibre Channel Switch
SANbox Express 1400
the
FIBRE CHANNEL SWITCHES
FIBRE CHANNEL SWITCH
Gb
2
Plug and Play Installation
Simple wizard tools lead you the installation and
configuration of the SAN. Seamless integration with
the SANsurfer Express tool provides management of
your SAN plus Microsoft VDS compliant storage
from a single tool!
Incredibly Low Cost
As an entry level switch, the smallest business can
now afford and enjoy the benefits of networked
storage without having to become a storage expert.
Small, Powerful Package
At only 2lbs and 6” deep, the SANbox 1400 requires
only half a slot to maximize your rack usage. Now,
2 units can be placed in a single slot for a total of 20
ports in 1U - maximum port density and power with
minimum investment!
Features
• 10 2Gb device ports
• Auto-sensing, self-configuring ports
• SANsurfer Express support
• Configuration Wizard software tool to simplify switch installation and fabric scaling
• Track configuration changes with Fabric Tracker
• Zoning Wizard for device security
• In-band, out-of-band, Telnet and SNMP management access
• 1U half-width rack form-factor
• Non-Disruptive Code Load and Activation (NDCLA)
• Interoperable with all FC-SW-2 compliant Fibre Channel switches
• I/O StreamGuard for RSCN Suppression
• “No-Wait” routing – guaranteed maximum performance independent of data traffic
10 Ports, 2Gbps
Fibre Channel
Switch
SANbox 1400
Series
SANbox Express
™
Pervasive Interoperability
Interoperable with popular servers, storage and
networking products from major manufacturers
including: ADIC, Brocade, Cisco, Computer
Associates, Dell, EMC, Emulex, HDS, HP, IBM, LSI,
McData, Microsoft, Quantum, StorageTek, Sun,
VERITAS, and many others.
SN0058036-00 Rev B 7/05
Plug and Play Fibre Channel Switch
For a list of authorized resellers, visit www.qlogic.com/buyqlogic/home_buy.asp
Standards
Fibre Channel Ports
• Physical & Signaling Interface Rev. 4.3 (FC-PH)
• Physical & Signaling Interface-2 (FC-PH-2)
• Physical & Signaling Interface-3 (FC-PH-3)
• Fabric Generic Requirements (FC-FG)
• Generic Services (FC-GS)
• Generic Services-2 (FC-GS-2)
• Generic Services-3 (FC-GS-3)
• Switch Fabric (FC-SW-2)
• Arbitrated Loop Rev. 4.6 (FC-AL)
• Arbitrated Loop-2 Rev. 7(FC-AL-2)
• Fibre Loop Attachment (FC-FLA)
• Tape Technical Report (FC-Tape)
• Virtual Interface Architecture Mapping (FC-VI)
• Element MIB Specification
• Fibre Alliance MIB Specification
Fibre Channel Classes of Service
• Classes 2, 3 connectionless
Modes of Operation
• Fabric
• Public Loop
Performance Features
Fabric Port Speed
• 2Gb/s, full-duplex, auto-negotiating for
compatibility with existing 1-Gb devices
Fabric Latency
• Less than 0.4 µs (best case, no contention)
• Cut-through routing
Fabric Point-to-Point Bandwidth
• 412 MB/s Full Duplex per port
Fabric Aggregate Bandwidth
• Single chassis: Over 40 Gb/s (full duplex)
end-to-end
• Non-blocking architecture
Maximum Frame Sizes
• 2148 bytes (2112 byte payload)
Per-port Buffering
• ASIC-embedded memory (non-shared)
• Each port has a guaranteed 16-credit zero wait
state buffer for full performance up to10km
Scalability
Ports Per Chassis
• (10) 2Gb / 1Gb ports
Multi Switch Fabrics
• Supports E-port link to another switch
• In-order delivery of frames in all multi-switch
and multi-link configurations
Fabric Port Types
• All ports can assume the following states:
- F_port: Fabric
- FL_port: Fabric loop (public loop)
- E_port: Switch-to-switch (single connection)
• Ports are auto-discovering, self-configuring
Media Type
• Hot-pluggable, industry-standard SFPs (Small Form
Pluggable)
Supported SFP Types
• Shortwave: 500 m (1,640 ft.)
• Longwave: 10 km (6.2 mi.)
Media Transmission Ranges
• Optical
- Shortwave: 500 m (1,640 ft.)
- Longwave: 10 km (6.2 mi.)
Cable Types
• 50/62.5 micron multimode fiber optic
• 9 micron single-mode fiber optic
Interoperability
• Compatible with FC-SW-2 compliant
switches
• Management interoperability with leading
SAN management applications
Fabric Management
Management Processor
•
Pentium class Processor
Management Methods
•
Integrated with SANsurfer Express (VDS
support for leading storage providers)
• SANsurfer Switch Manager management
tools
• SNMP, Telnet, GS-3
Access Methods
•
In-band
•
Ethernet 10/100 BaseT with RJ45
Diagnostics
•
Power-up self-test of all functionality except media
modules
•
Field-selectable full self-test including media modules
Fabric Services
•
Simple Name Server
• Fabric Zoning
• Registered State Change Notification
(RSCN)
• I/O StreamGuard
User Interface
• LED indicators, command-line console, and
web-based utilities
Mechanical
Enclosure Types and Options
• Desktop/shelf top with included rubber feet
• Optional rack mounting kit for mounting up to two
SANbox 1400 units
Dimensions
• Width: 190.5 mm (7.5” )
• Height: 41.9 mm (1.65” ) (1U)
• Depth: 155.6 mm (6.125”)
Weight
• 0.9 kg (2 lbs)
©2004-2005 QLogic Corporation. All rights reserved. QLogic, SANbox and SANsurfer are registered trademarks of QLogic Corporation. The QLogic logo, SANguard, SANmark, SANbox Manager,
I/O Stream Guard and Multistage are trademarks of QLogic Corporation, which may be registered in some jurisdictions. All other brands and product names are trademarks or registered trade-
marks of their respective holders. Information supplied by QLogic Corporation is believed to be accurate and reliable. QLogic Corporation assumes no responsibility for any errors in this
brochure. QLogic Corporation reserves the right, without notice, to make changes in product design or specifications.
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
WWW.QLOGIC.COM
Europe Headquarters
QLogic (UK) LTD.
Surrey Technology Centre
40 Occam Road Guildford
Surrey GU2 7YG UK
+440(0)1483 295825
Corporate Headquarters
QLogic Corporation
26650 Aliso Viejo Parkway
Aliso Viejo, CA 92656
949.389.6000
TECHNICAL SPECIFICATIONS
Gb
2
SANbox Express
™
SANbox 1400
Series
Harmonics
• EN 61000-3-2
Immunity
• EN 55024:1998
Marking
• FCC Part 15
• UL (USA)
• TUV (USA)
• cUL (Canada)
• cTUV (Canada)
• TUV (Europe)
• VCCI
• CE
Power Supply/Cooling
• External laptop-style power supply
• Front to back airflow with integrated
cooling fan
Environmental
Operating
• Temperature: 5 to 40 °C (41 to 104°F)
• Humidity: 15% to 90% noncondensing
• Altitude: 0 to +15,000 feet
• Vibration: IEC 68-2
5-500 Hz, random, 0.21 G rms
• Shock: IEC 68-2
4 g, 11ms, 20repetitions
Non-Operating
• Temperature: -40°C to 70°C (-40 to 158 °F)
• Humidity: 25% to 93% noncondensing
• Altitude: 0 to +50,000 feet
• Vibration: IEC 68-2
5 to 500 Hz, random, 2.09 G rms,
• Shock: IEC 68-2
30g, 292 ips, 3 repetitions, 3 axis
Electrical
Operating Voltage
• 90-265 Vac, 47-63 Hz
Power Source Loading
• 20VA
Heat Output
• 25W maximum (with full optics configuration)
Regulatory
Safety Standards:
• UL 60950 (USA)
• CSA 22.2 No.60950
(Canada)
• EN60950 (EC)
• CB Scheme-IEC 60950
Emissions Standards
• FCC Part 15B Class A
(USA)
• VCCI Class A ITE
(Japan)
• ICES-03 Issue 3
(Canada)
• EN55022 Level A (EC)
• CISR 22, Class A
Voltage Fluctuations
• EN 61000-3-3
Ordering Information
SB1403-10AS Switch unit
SB1403-10AJ Switch unit with 10-PAK
small form-factor pluggable
optics (SFP)
SB1400-RACKKIT Optional rack mounting kit
(supports up to two SANbox 1400 units)
SB1400-PS External power supply
replacement kit

Other manuals for SANbox 1400 Series

5

Other Qlogic Switch manuals

Qlogic SANbox 5000 Series User manual

Qlogic

Qlogic SANbox 5000 Series User manual

Qlogic SilverStorm 9024 User manual

Qlogic

Qlogic SilverStorm 9024 User manual

Qlogic SANbox 3810 User manual

Qlogic

Qlogic SANbox 3810 User manual

Qlogic 3000 Series User manual

Qlogic

Qlogic 3000 Series User manual

Qlogic SANbox 5602 User manual

Qlogic

Qlogic SANbox 5602 User manual

Qlogic SANbox 5800V Series User manual

Qlogic

Qlogic SANbox 5800V Series User manual

Qlogic SANbox 5602 User manual

Qlogic

Qlogic SANbox 5602 User manual

Qlogic SilverStorm 9000 Instruction Manual

Qlogic

Qlogic SilverStorm 9000 Instruction Manual

Qlogic StorEdge Sun StorEdge Manual

Qlogic

Qlogic StorEdge Sun StorEdge Manual

Qlogic SANbox 5000 Series User manual

Qlogic

Qlogic SANbox 5000 Series User manual

Qlogic SANbox2-8c User manual

Qlogic

Qlogic SANbox2-8c User manual

Qlogic SANbox 9100 Instruction Manual

Qlogic

Qlogic SANbox 9100 Instruction Manual

Qlogic SANbox 1400 Series User manual

Qlogic

Qlogic SANbox 1400 Series User manual

Qlogic SilverStorm 9000 Manual

Qlogic

Qlogic SilverStorm 9000 Manual

Qlogic SilverStorm 9120 User manual

Qlogic

Qlogic SilverStorm 9120 User manual

Qlogic SANbox 5800V Series User manual

Qlogic

Qlogic SANbox 5800V Series User manual

Qlogic SANbox 5800V Series User manual

Qlogic

Qlogic SANbox 5800V Series User manual

Qlogic SANbox 5800V Series User manual

Qlogic

Qlogic SANbox 5800V Series User manual

Qlogic SANbox 5802V User manual

Qlogic

Qlogic SANbox 5802V User manual

Qlogic SANbox-16STD Installer's/ User manual

Qlogic

Qlogic SANbox-16STD Installer's/ User manual

Qlogic SANbox 5000 Series User manual

Qlogic

Qlogic SANbox 5000 Series User manual

Qlogic SANbox 3050 User manual

Qlogic

Qlogic SANbox 3050 User manual

Qlogic SANbox 9000 Series User manual

Qlogic

Qlogic SANbox 9000 Series User manual

Qlogic SANbox2 SANbox2-64 Manual

Qlogic

Qlogic SANbox2 SANbox2-64 Manual

Popular Switch manuals by other brands

Allied Telesis x330 Series installation guide

Allied Telesis

Allied Telesis x330 Series installation guide

Roland FS-1-WL Connection guide

Roland

Roland FS-1-WL Connection guide

Targus desktop USB 2.0 7-port hub user guide

Targus

Targus desktop USB 2.0 7-port hub user guide

Keystone Keystone F792 Specification sheet

Keystone

Keystone Keystone F792 Specification sheet

HP AA-RSB6B-TE installation guide

HP

HP AA-RSB6B-TE installation guide

ATEN VP2730 user manual

ATEN

ATEN VP2730 user manual

Kramer VP-774A user manual

Kramer

Kramer VP-774A user manual

Hamilton DSIP-DOCK owner's manual

Hamilton

Hamilton DSIP-DOCK owner's manual

Dahua PFS3211 quick start guide

Dahua

Dahua PFS3211 quick start guide

Veris Industries Hawkeye 909 installation guide

Veris Industries

Veris Industries Hawkeye 909 installation guide

HP 5120 SI Series specification

HP

HP 5120 SI Series specification

ZyXEL Communications PLA4225 quick start guide

ZyXEL Communications

ZyXEL Communications PLA4225 quick start guide

Walthers 942-101 Mounting instructions

Walthers

Walthers 942-101 Mounting instructions

Steren V0310 instruction manual

Steren

Steren V0310 instruction manual

Juniper QFX3000-G QFabric Deployment guide

Juniper

Juniper QFX3000-G QFabric Deployment guide

Niko 410-00001 manual

Niko

Niko 410-00001 manual

Korenix JetNet3008G V2 Quick installation guide

Korenix

Korenix JetNet3008G V2 Quick installation guide

SMC Networks ISE20B Operation manual

SMC Networks

SMC Networks ISE20B Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.