(1’ x 2’) SYSTEM 5 includes 8-Ohm, /25RS versions and /70RS versions
(2’ x 2’) SYSTEM 12 includes 8-Ohm, /25RS versions and /70RS versions, SYSTEM 19– includes 25RS and /70RS versions
INSTALLATION INSTRUCTIONS
© 2012 Quam-Nichols Company Quam-Nichols reserves the right to make changes and/or improvements to its products at any time and without notice.
Tie-off
tab 2x
TIE OFF
TAB * 4
Tie-off
tab 4x
12– 9.4 8089
3. Remove cable /conduit clamp fitting from plate;
install UL Listed metallic enclosure entry fitting for
plenum cable or flex whip.
4. Feed supply cable through whip to connector.
Make connections per wiring diagrams lower left below;
insulate all unused taps from each other and enclosure.
When cover plate is secured, all connections / splices and
unused leads must be inside of the enclosure.
5. Place assembly onto ceiling grid, install 24” T-bar
trim piece where required (furnished only with specific
1’x2’ formats).
NOTE! AHJ/ local codes may require tie-off to structure.
Bend up tie-off tabs as shown in illustration and install as
directed.
NOTE! AHJ/ local codes may require tie-down to grid.
Recommended fasteners;
not supplied
: Erico/Caddy part
ATA4i and 1/4”-20 x 2” bolt, or equivalent. Install as
directed.
6. Place remaining ceiling tile into opening as required.
Brown 5W @ 25V only
Red 2.5W @ 25V only
Violet only 0.32W @ 70.7V
Gray only 0.63W @ 70.7V
Blue only 1.25W @ 70.7V
White 0.32W @ 25V or 2.5W @ 70.7V
Green 0.63W @ 25V or 5W @ 70.7V
Orange 1.25W @ 25V only
BLACK ( Common )
8Ω
QUAM Model TBLU
BLACK ( Common )
8Ω
QUAM 8-Ohm Operation
RED
INTENDED USE:
All versions: Indoor environment, mounted parallel to floor
plane in a 24” wide, suspended ceiling tile grid; mount height
18’ or less above floor plane.
Program material: Signal tones, voice and
music.
UL Listed 1480
City of Chicago ÍApproved
“ Material and construction permits use
where ceiling plenum is part of the air
handling system”
Type G– General Signaling
1. Cut ceiling tile as required:
1’ x 2’ FORMAT LOUDSPEAKER
2’ x 2’ tile – Cut tile in half along one axis.
2’ x 4’ tile – Cut 12” from edge along 2’ axis and
discard smallerpiece.
2’ x 2’ FORMAT LOUDSPEAKER
2’ x 2’ tile – No cutting required.
2’ x 4’ tile – Cut tile in half along 2’ axis.
!Steps 2-3 only– Required if using conduit clamp fitting
other than what is provided
with product
2. Loosen, but do not remove screws on cover plate;
push up and remove plate from assembly.
BLACK ( Common )
8Ω
QUAM /25RS and /70RS Rotary Select
QUAM /25RS and /70RS Rotary Select
4W
0.25W
0.5W
1W
2W
OFF
RED