Quantum Rehab Network Adapter Dynamic DX User manual

Dynamic DX
Specialty Controls Remote
(SCR)
Basic Operation Instructions

2 Basic Operation Manual SCR
Copyright © 2001
Pride Mobility Products Corporation
This manual describes basic operation for the Dynamic DX Specialty Controls
emote (SC ) only and must be read in conjunction with the owners manual
supplied with your power chair. Please read both manuals in their entirety
before operating the SC or your power chair.
This manual is intended as a supplement to the in-service training provided
by your authorized provider. If you have any questions or problems regarding
the SC , please contact your authorized provider.
IMPORTANT NOTICE

SCR Basic Operation Manual 3
TABLE OF CONTENTS
INTRODUCTION ................................................................................ 4
Dynamic DX Specialty Controls emote (SC )....................................... 4
SCR CONTROLS ................................................................................ 6
STANDARD MODE CONFIGURATION ...................................... 6
Driving in Standard Mode Configuration .................................................. 6
TIMEOUT FUNCTION ...................................................................... 7
SEAT CONTROL ................................................................................. 7
Tilt Mode ................................................................................................... 7
ecline Mode............................................................................................. 8
Left Leg est Mode ................................................................................... 8
ight Leg est Mode ................................................................................. 9

4 Basic Operation Manual SCR
INTRODUCTION
Welcome to Quantum ehab, a Division of Pride Mobility Products
Corporation. Quantum ehab is dedicated to the customization of power
chairs for users with advanced rehabilitation and mobility issues. Quantum
ehab also expands possibilities for enhanced healthcare attendant control
over power chair functions to provide a secondary level of support for our
customers where necessary.
The Dynamic DX Specialty Controls Remote (SCR)
The Dynamic DX Specialty Controls emote (SC ) allows users to control
a wide range of on-chair and off-chair functions. SC units come pre-
programmed in the Standard Mode Configuration explained in this manual,
but are not limited to it. Please contact your authorized provider for more
information on programming alternatives.
The SC is used in conjunction with input devices such as joysticks, touch
pads, lap trays, head arrays, Buddy Buttons, Sip-N-Puff systems, etc. The
purpose of the SC is to enhance and expand input device function, so that
the user can do more with his/her power chair.
This manual is designed to explain basic operation for the following functions:
1. SC Controls
- Utilizes the On/Off Switch and the Mode Switch to power the SC and
choose pre-programmed functions.
2. Standard Mode Configuration
- Allows the user to choose and control the driving speed of his/her power
chair using one of five modes.
3. Timeout Function
- This is a safety feature built in to the programming of the SC .
4. Seat Control
- Allows the user to control seat actuator adjustment.

SCR Basic Operation Manual 5
Figure 1. SCR Components and Connections
Mode Switch
Cycles through the
programmed modes.
LCD Display
4-line, 20 character
backlit LCD which
shows all functions
and instructions.
On/Off Switch
Toggles the entire DX
control system between
the On & Off modes.
Battery Meter
Battery charge level
is indicated by a
set of six LEDs.
Reverse Indicator
Disregard - this is a non-
functioning feature.
HHP/Wizard Port
Allows connection to an IBM
computer for custom
programming and where
standard drive programming
occurs with the HHP.
DXBUS Socket
For connecting the DX Remote
with a DXBUS cable to other
DX compatible modules
Battery Charger Port
Standard 3-pin XLR type
battery charger socket used
with off-board charging
systems.
External Switch Jacks
Three 3.5 mm (1/8") jack
sockets to allow connection of
external switches
Figure 1 provides information on the SC components and connections.
Use this diagram to familiarize yourself with the function and location of
each component before using the SC .

6 Basic Operation Manual SCR
SCR CONTROLS
The SC has only two built-in controls: the On/Off Switch and the Mode
Switch (see figure 1). The On/Off Switch simply controls power to the SC .
The Mode Switch cycles the SC through eight possible program modes.
Only five of the eight possible program modes are used in the Standard Mode
Configuration. All five program modes are Drive Modes (see Standard Mode
Configuration).
STANDARD MODE CONFIGURATION
Quantum ehabs Standard Mode Configuration for the SC encompasses
five drive programs, all of which control driving speed as a percentage of
maximum speed. The slowest is Drive Mode 1; the fastest is Drive Mode 5.
Actual maximum speed varies according to the power chair model.
Driving in Standard Mode Configuration
Driving in Standard Mode Configuration is simple. Power up the SC using
the On/Off Switch (either onboard or plugged into the external On/Off Switch
jack). The LCD Display will show Drive Mode 1 and prompt the user to
select one of three options (see figure 2):
DRIVE MODE 1
PREVIOUS
YES
NEXT
Figure 2. Drive Program Selection
1. Previous (down arrow)
- eturns the SC to the previous
state (in this case, powered
down)
2. Yes (right arrow)
-Selects Drive Program 1
3. Next (up arrow)
-Selects the next option (in this
case, Drive Program 2)
Using the input device, select the drive program most appropriate to the
current environment, e.g., indoor setting versus outdoor setting. Choosing
the Next command will cycle the SC through the drive programs. The
LCD display will change with each option selection.

SCR Basic Operation Manual 7
TIMEOUT FUNCTION
The timeout function is a safety feature in the nature of an automatic sleep
mode. When the SC is powered up, the user has ten seconds to begin driving
the power chair. If the user begins driving the power chair within ten seconds
of power up, the timeout function is suspended until the unit is stationary
again. If the user does not begin driving the power chair within ten seconds
of power up, the timeout function automatically exits to the Main Screen
Display.
SEAT CONTROL
Executing a Next command with the input device when in Drive Mode 5
moves the SC to the Seat Control Menu. See figure 3. To enter the Seat
Control Mode, choose the Yes option. In this mode, the user can control
the adjustment of the available seat actuators, including Tilt, ecline, Left
Leg est, and ight Leg est. Each
mode will prompt the user to
choose one of four options (see
figures 4-7):
Tilt Mode
1. Down (up arrow)
- eturns the seat to an upright
position.
2. Up (down arrow)
-Adjusts the actuator to the
desired tilted position.
3. Exit (left arrow)
- eturns the SC to the Seat
Control Menu
4. Next (right arrow)
-Moves the SC to the next
actuator option.
SEAT CONTROL
PREVIOUS
YES
NEXT
Figure 3. Seat Control Selection
SEAT CONTROL
EXIT
DOWN UP
NEXT
TILT
Figure 4. Tilt Mode Selection

8 Basic Operation Manual SCR
Recline Mode
1. Up (up arrow)
- eturns the seat to an upright
position.
2. ecline (down arrow)
-Adjusts the seat to the desired
position.
3. Previous (left arrow)
- eturns the SC to the previous
actuator option.
4. Next (right arrow)
-Moves the SC to the next
actuator option.
Left Leg Rest Mode
1. Down (up arrow)
-Lowers the leg rest.
2. Up (down arrow)
- aises the leg rest.
3. Previous (left arrow)
- eturns the SC to the previous
actuator option.
4. Next (right arrow)
-Moves the SC to the next
actuator option.
SEAT CONTROL
PREVIOUS
UP RECLINE
NEXT
RECLINE
SEAT CONTROL
PREVIOUS
DOWN UP
NEXT
LEFT LEG
Figure 5. Recline Mode Selection
Figure 6. Left Leg Rest Mode
Selection

SCR Basic Operation Manual 9
Right Leg Rest Mode
1. Down (up arrow)
-Lowers the leg rest.
2. Up (down arrow)
- aises the leg rest.
3. Previous (left arrow)
- eturns the SC to the previous
actuator option.
4. Exit (right arrow)
-Moves the SC to the next
available menu.
SEAT CONTROL
PREVIOUS
DOWN UP
EXIT
RIGHT LEG
Figure 7. Right Leg Rest Mode
Selection

10 Basic Operation Manual SCR
NOTES

SCR Basic Operation Manual 11
NOTES

12 Basic Operation Manual SCR
Exeter, PA
Quantum Hotline: 1-866-800-2002
Visit the Rehab Zone at:
www.quantumrehab.com
INFMANU1746/A/MAY 2001
Other manuals for Network Adapter Dynamic DX