Quasar Clear Rayz User manual

PLEASE READ ALL INSTRUCTIONS BEFORE USE
INSTRUCTION MANUAL
!
Copyright. © 2013 Quasar Bio-Tech, Inc. All Rights Reserved.
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

WHAT DOES THE RED-LIGHT SIDE DO?
•The RED LIGHT is used to
reduceinammation.
WHAT DOES THE BLUE-LIGHT SIDE DO?
•The BLUE LIGHT kills the
p. acnes bacteria that causes breakouts.
WHO WE ARE..............................................................................................................................................1
HOW IT WORKS ........................................................................................................................................1
WHO SHOULD USE CLEAR RAYZ?.......................................................................................... 2
SETUP.............................................................................................................................................................. 2
TEST FOR LIGHT SENSITIVE SKIN........................................................................................... 2
TREATMENT RED LIGHT / BLUE LIGHT ..........................................................................2-3
TIPS FOR USE............................................................................................................................................ 3
BEFORE / AFTER .................................................................................................................................... 3
WHAT TO EXPECT.................................................................................................................................4
OTHER PRODUCTS / FILLERS.....................................................................................................4
AFTER EACH TREATMENT.............................................................................................................. 5
PRODUCT CARE...................................................................................................................................... 5
PROBLEMS.................................................................................................................................................. 5
RISKS ............................................................................................................................................................... 5
CONTRAINDICATIONS......................................................................................................................6
WARNINGS..................................................................................................................................................6
ELECTIC SHOCK WARNINGS.......................................................................................................6
PRECAUTIONS ........................................................................................................................................ 7
WARRANTY INFORMATION..........................................................................................................8
SPECIFICATIONS.................................................................................................................................... 7
CUSTOMER SERVICE..........................................................................................................................8
PROGRESS NOTES / TREATMENT LOG ...............................................................................8
TABLE OF CONTENTS
BLUE
LIGHT
RED
LIGHT
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

1
WHO WE ARE / HOW IT WORKS
WHO WE ARE
*qua-sar (kway-sar): any class of celestial objects that resemble
stars but whose large redshift and apparent brightness imply
extremeenergyoutput.
QuasarBio-Techwasfoundedin2005onthebeliefthatoering
premium products with outstanding customer care was the only
way to do business. Today, our continued success is due in large
part to you—our clients. We would like to thank you for your
continued support of our endeavors.
LocatedinSarasota,FLsince2007,weprideourselvesinbeingasmall
businesswithbigdreamstocontinueoeringskincareproductsthat
aidourclientsinfeelingandlookingtheirbest.Weareextremely
proudtomanufactureourproductshereintheUnitedStates.
Quasar Bio-Tech looks forward to your continued support,
suggestions, and success stories.
HOW IT WORKS
ClearRayzcombinestwodistinctwavelengthsoflight(RED and BLUE)
that when used as directed, helps to kill the acne bacteria (p. acnes) that
causesinammatoryacneandtohealtheskin.How?
Propionibacteria acnes(p.acnes)arenormalresidentsoftheskin,
and are generally harmless, but when pores become lled with
excess oil and dead skin cells, it causes p. acnes to thrive.
P. acnes triggers inammation within the pore creating papules,
pimples, or cysts. Reducing the p. acnes presence is an essential
step in controlling acne and preventing new bacterial growth.
Science has proven that blue-spectrum light kills these bacteria and
the red-spectrum light heals the inamed skin.
TABLE OF CONTENTS
BLUE
LIGHT
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

2
WHO SHOULD USE / SETUP / TEST / TREATMENT TREATMENT STEPS / TIPS FOR USE
SETUP
1. InsertthepowerplugintothebottomoftheClearRayztool.
2. Plug the power supply into the wall.
3. PresstheOn/Oswitchtomakesuretoolisfunctional.
TEST FOR LIGHT-SENSITIVE SKIN
1. Placetheredlightsidedirectlyonyourarm.Turnonthetool
andmoveitasweepingmotionintheareaforthefullcycle
(thetoolwillturnoautomaticallyattheendofthecycle).
2. Ifyouhavepainorredness,youmayhavelight-sensitiveskin.
TREATMENT REGIMEN
Treatment is one (1) day of RED (entire face) for 30 minutes and
one (1) day of BLUE (entire face) for 20 minutes per WEEK for
inflammatory acne.
TREATMENT STEPS RED LIGHT THERAPY
1. Start by cleansing your face.
2. Pushthebuttononetime,theredlightwillcomeon.
3. PlacetheClearRayztoolgentlyontheskinintherstarea
you are treating.
4. Movethetoolinaslowcircularorsweepingmotion.Treat
withintheareafor7½minutesuntilthetoolemitsasoft
toneandthetoolshutso.
5. Turn the tool back on and repeat until all areas have been
treated.
6. Theentirefacetreatmentwillbe30minutes.
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

3
WHO SHOULD USE / SETUP / TEST / TREATMENT TREATMENT STEPS / TIPS FOR USE
TREATMENT STEPS BLUE LIGHT THERAPY
1. Start by cleansing your face.
2. Pushthebuttontwo(2)timesuntilthebluelightison.
3. PlacetheClearRayztoolgentlyontheskinintherstarea
you are treating.
4. Movethetoolinaslowcircularorsweepingmotion.Treat
withintheareafor5minutesuntilthetoolemitsasofttone
andthetoolshutso.
5. Turn the tool back on and repeat until all areas have been
treated.
6. Theentirefacetreatmentwillbe20minutes.
Note: Do not place the tool directly over the eyelids and keep
your eyes closed when treating around the eyes.
TIPS FOR USE
•When treating your forehead or your chin area, use back and
forthsweepingmotions.
• Whentreatingonyourcheeks,useaslowcircularmotion.
• Ifyouhaveinammationora“breakout”occurs,add
additionaldaysofRedLightTherapyuntiltheinammation
subsides
•DO NOTdoRedandBluetreatmentsonthesameday.
AlwaysdoRedandBluetreatmentsonalternatingdays.
AfterBefore
Unenhanced
photos
FOR MILD TO MODERATE INFLAMMATORY ACNE
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

4
WHAT SHOULD I EXPECT IN THE FIRST
WEEK(S) OF USE:
Youshouldexpectyouracnetoworsenbeforeitimproves.Thisis
completelynormal.Theredlightspenetratetothedeepestcellsin
yourskin.Therefore,whiletheappearanceofyourskinmaywors-
en, you are actually treating the acne at its roots. As your pores de-
toxify,thesebumandthedeadbacteriawillsurface.Useaddition-
alRedtreatmentstohealtheskin’ssurfaceofanyinammation.
USING PRODUCTS WITH YOUR CLEAR RAYZ TOOL
If you use other products while treating with the Clear Rayz tool, we
suggestyoudoaproductlight-sensitivitytestonyourarmbefore
applyingproducttoyourfaceanddoingtreatmentswiththeQuasar
tools. Acne products can be harsh and cause irritation and the light
couldamplifythisirritation.
Refrain from using creams or lotions until AFTER you complete
yourtreatment.Creamsandlotionscancauseabarriertotheskin
preventing light penetration.
INJECTIONS/FILLERS/MICRODERMABRASION/
CHEMICAL PEELS
Afterreceivinginjections/llers,wait2weeksbeforetreatingthearea
oftheinjection/ller.Thiswillgivetheinjection/llertimetosettle.
YoumayuseyourClearRayztoolimmediatelyafteramicrodermabra-
siontreatmentorchemicalpeel.
NOTE:Makesureallproductsfromthechemicalpeelarecompletely
washedothefacebeforeusingthelight.
WHAT TO EXPECT / OTHER PRODUCTS / FILLERS AFTER TREATMENT /TOOL CARE/ PROBLEMS / RISKS
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

5
AFTER TREATMENT /TOOL CARE/ PROBLEMS / RISKS
AFTER EACH TREATMENT
Werecommendusingamoisturizeraftereachtreatmenttoensure
yourskinissucientlyhydrated.Applymake-uporotherskincare
products as you like. Quasar Tools do not cause sun sensitivity.
CARE FOR YOUR TOOL
Useasoft,dampclothoralcoholwipetocleanthetool’ssurfaces.Store
the tool in a cool, dry place. Do not use any disinfectants (except an
alcohol wipe) on your tool.
PROBLEMS?
*DO NOT TRY TO FIX THE CLEAR RAYZ TOOL YOURSELF.
CONTACT US IMMEDIATELY IF ANY PROBLEMS ARISE.
RISKS
• There is a risk of light sensitivity.
• Duringtreatments,thereisariskofdryingandrednessof
the skin.
•Do not place the tool directly over the eyelids and keep
your eyes closed when treating around the eyes.
Yoursafetyisourprimaryconcern.Readinstructionmanual
thoroughly before using Clear Rayz tool.
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

6
CONTRAINDICATIONS
•
DONOTUSEtheClearRayztotreatmoles,warts,ingrown
hairs, blackheads, whiteheads or insect bites.
•
DONOTUSEtheClearRayzexceptforthetreatmentof
mildtomoderateinammatoryacne.
•
DO NOT USE the Clear Rayz to treat if you have skin
infections, open sores, or wounds.
WARNINGS
•
DO NOT USE the Clear Rayz in water (including your sink,
bathorshower).Youcouldgetamildelectricshock.
•
DO NOT USE the Clear Rayz if the wall power unit has a
frayed cord or the prongs are bent or loose. You could get a
mildelectricshock.
•
DONOTTAKEAPARTtheClearRayzasthismaycause
damage,malfunctionorreANDyoucouldgetamild
electric shock.
ELECTRICAL SHOCK WARNING
•
DO NOT USE the Clear Rayz in water (including your
sink,bathorshower).Youcouldgetamildelectricshock.
•
DO NOT USE the Clear Rayz if the wall power unit has
a frayed cord or the prongs are bent or loose. You could
get amildelectricshock.
•
DONOTTAKEAPARTtheClearRayzasthismaycause
damage,malfunctionorreANDyoucouldgetamild
electric shock.
CONTRAINDICATIONS/ WARNINGS / SHOCK
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

7
PRECAUTIONS FOR BEST RESULTS
•
ALWAYS check your Clear Rayz before using. Test the unit
by seeing that the red and blue LEDs are working. Please,
onlyglanceatthelightfromtheside,NOTstraighton.Please
DO NOT
stare at the light as it is very bright.
•
ALWAYS clean your Clear Rayz after each use. Unplug your
ClearRayz,THENuseadamp(notwet)clothoralcoholswab
and wipe the surface.
•
USEONLYthepowerunitthatcamewithyourClearRayz.
OtherpowerunitswilldamageyourClearRayzand
will cancel your warranty.
•
NEVERcleanyourClearRayzwithheat;itcandamageyour
Clear Rayz.
WARRANTY INFORMATION
It is important to register your device with us to ensure the
FIVE-YEAR warranty oered. It only takes a minute to register
your tool at www.babyquasar.com or just complete the enclosed
warrantycardanddropinthemail.Registrationmustbecompleted
and returned within 20 days of purchase. Your Clear Rayz tool is
guaranteedfreefrom defectsinmaterials andworkmanshipunder
normaluseforaperiodofFIVE(5)yearsafteritsoriginalpurchase
date. This warranty is not transferable if you sell your Clear Rayz tool
toanotherparty.Ifanyproblemssurfaceduringthisve-yearperiod,
contact our friendly, helpful customer services representatives
immediatelytoallowustheopportunitytorectifyanyconcerns.
NorthAmerica,calltoll-free(800)944-1523forrepairorreplacement.
OutsideofNorthAmerica,call(941)306-5812.
Contactinformationalsoavailableatwww.babyquasar.com.
CONTRAINDICATIONS/ WARNINGS / SHOCK PRECAUTIONS / WARRANTY
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

8
CLEAR RAYZ DESCRIPTION
SPECIFICATIONS
• Size–3.6inchesX2.6inchesX1.3inches
• Weight–3ounces
• 3minutetreatmenttimer
• 100-240vac,50-60Hzuniversalpowersupply
CUSTOMER SERVICE
Our friendly and helpful customer service representatives are eager
tohelpyouinanywaypossible.Pleasefeelfreetocallusfrom9-5
p.m.,MondaythroughFriday,EasternTime,USA.Youmayalsoemail
us questions.
Please contact us:
Quasar Bio-Tech, Inc.
1431 Tallevast Rd. Sarasota, FL 34243
(800)944-1523(toll-free)
(941)306-5812(voice)
(941)306-5816(fax)
www.babyquasar.com
SPECIFICATIONS / CUSTOMER SERVICE
2.6”1.3”
66.04mm 33.02mm
3.6”
91.44mm
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

9
SPECIFICATIONS / CUSTOMER SERVICE PROGRESS NOTES / TREATMENT LOG
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

LAB-049-C
All Rights Reserved
Printed05September2013
51287
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor
Table of contents
Other Quasar Personal Care Product manuals