Operations & Maintenance Manual
CollectALL
MedEVAC MultiPure
PowerStation PS2
SHIPPED WITH THE UNIT (LOOSE):
Model
Ships with:
CollectALL Open Filter Door: PowerCord, air inlet plate, clamps, Remote Hand-Switch
Outside the unit 12-ft long, 3” diameter hose
MedEVAC Multipure Open Filter Door: PowerCord, air inlet plate, Remote Hand-Switch, (3) Rubber
hose cuffs (2 for 1.5” accessory, 1 for 2.5” accessory)
Outside the unit: 18-ft hose
PowerStation (PS2) Open Filter Door: PowerCord, air inlet plate, milling Auto-Start Cable
Outside the unit: 6-ft long hose
INSTALLATION
1) Open filter door, remove plastic around HEPA filter (and Odor Filter if applicable)
2) Ensure filter bags are properly installed, fit into 2 tubes beneath the top of filter section
3) INSTALL CASTERS (WHEELS) IF THIS OPTION WAS PURCHASED (#AA037)
4) Plug Power Cordset to a grounded 120-volt wall outlet
4) Connect to applicable work-station/milling machine
START-UP
1) Press red POWER button on control panel to ensure unit STARTS
“System ON” LED illuminates, indicates unit is operating
2) Press POWER button again to switch unit OFF
3) You are now ready to operate
4) Connect remote hand-switch (PN AA375 or foot-pedal (PN AA175) to the remote
socket on the control panel to start unit remotely
If: “System ON” LED is OFF (indicates unit NOT operating)
If: “Remote/Standby” LED flashes (indicating unit is in WAITING MODE)
If: “Remote/Standby” LED ON (indicating unit is OPERATING)

QUATRO
Air Technologies Inc.
----------------------------------------------------------------
Engineers Of Clean Air
----------------------------------------------------------------
30 Hymus Boulevard, Montreal, Quebec, H9R 1C9 Tel.: (514) 630-4444 Fax: (514) 630-4454 website: www.quatroair.com info@quatroair.com
SAFETY PRECAUTIONS
Carefully read instructions in this manual before operation (keep manual as it contains information for proper operation and maintenance). Keep all fastening
hardware tight to ensure that the unit is in safe working condition. Familiarise yourself with the way in which the special filter is removed, installed, and serviced.
Filter must be in place whenever this machine is in operation. Use only on grounded electrical circuit; do not use two-wire electrical prong adapters to defeat the
three-pronged plug on the end of the cord. When servicing motor, be careful when touching exterior of motor when it is turned off; it may be hot enough to be
painful or cause injury. Do not substitute any other filter for the one supplied, as it will alter the design characteristics.
UNPLUG UNIT FROM ITS
POWER SUPPLY PRIOR TO SERVICING UNIT!
Ensuring Proper Grounding of ABS/PVC Fittings and Tubing for a Dust Collection System.
For dust collection systems, galvanized metal pipe and fittings are best, but for most typical applications, fittings and dust collection tubing made of plastic (ABS
or PVC) are sufficient, provided they are properly grounded to dissipate static electrical charges. Dust and air in the right proportions can be an explosive
mixture, and a build up of static electricity can provide the spark to ignite it.
To safely collect and bleed off the static charge, bare copper wire (not insulated) should be run along the inside of the duct-work and be attached to grounding
screws or a bare metal surface on both the dust collector and the unit that it is connected to (if it is connected to a unit). The power cords of both machines must
be terminated in a grounded three-prong plug to complete the connection to the ground. Wires over the irregularities of fittings, especially at “Y”s or “T”s could
form traps for particles. Therefore, bypass the fittings by running the wires to the outside through small holes. Seal the holes with silicone caulking compound
and join the wires by twisting them together and securing them with a wire nut. As charges can also collect on the outside surface, we recommend wrapping
bare copper wire in a spiral around the outside of the ductwork, securing it with electrical tape and connecting it to the ground system by means of wire nuts. If
you have any difficulty securing the hose clamp to the hose and fittings, try wrapping the joints with duct tape first to provide a good gripping surface. If you are
still having difficulty in obtaining a safe electrical ground, we recommend the services of a good electrician.
UNIT INSPECTION
Upon receipt, inspect unit for either visible or concealed damage. Damage should be immediately reported to the transport company.
If you suspect concealed damages inside the box indicate so on the transport companies’ shipping documents.
Single box, c/w all components required either on or inside the unit:
PRE START-UP CHECKLIST
a) Check that all internal components are present and are adequately supported;
b) Check that labels and serial numbers are present for future identification;
c) Verify power supply compatibility with equipment (120-volt/1 phase/60hz). Check that the unit is plugged into a grounded receptacle;
d) Ensure that rubber grommets are tight and secure prior to placing unit on the floor.
WARNING: DO NOT OPERATE UNIT UNLESS FILTER IS IN PLACE, AS MOTOR MAY BURN-OUT.
Dirty Air Inlet collars are to be installed on the BACK side of unit.
PRINCIPLE OF OPERATION
A four step AUTOMATIC method of operation:
a) Filter bags capture all heavy / larger particles; b) HEPA Filter captures and holds fine, lighter dust particles; c) odor filters (Model dependant) capture
applicable odors d) heavy duty blower section to overcome static pressure across the hose and filter.
UP/DOWN Arrows on control panel allow you increase and decrease speed in 9 increments.
AUTOMATIC (Remote) OPERATION
When power cord is plugged in and POWER button is pressed, unit will BEEP once, ALL lights will illuminate (unit is operational), unit will start
TEMP MODE FEATURE: While unit is in STANDBY MODE (Remote/Standby Led is flashing), Press POWER button to start motor, and press again to shut
motor OFF (this overrides the Remote Signal you are receiving from your hand-switch or foot-pedal)
Unplugging the power cord will automatically deactivate Remote Sensing Feature.
SYSTEM COMPONENTS
Nominal Airflow
220
Voltage, current
120/1/60, 15 amps
Approximate Dimensions:
26”h x 13”w x 16”d
Approx. Weight:
80lbs
EQUIPMENT MAINTENANCE PROCEDURES
Proper maintenance is critical to extend the life of the filtration system. The information presented below outlines basic maintenance procedures to ensure the
unit will provide trouble-free operation for years to come. The unit is designed to allow quick access to the Filter section for easy filter replacement.
FILTER REPLACEMENT
Filter requires replacement if appropriate LED on control panel illuminates (and beeper sounds for 2 seconds every 4 hours).
Filter replacement is ALSO required if you notice the following:
a) If you are losing suction capacity, after filter has been used…..FILTER IS CLOGGED;
b) If dust is coming through the filter and dust is present in the motor section even though filter is seated properly……..FILTER IS PUNCTURED;
c) Gasket on BASE of HEPA Filter is even slightly worn, GASKET NEEDS TO BE IN GOOD CONDITION TO ENSURE DUST DOES NOT GET THROUGH
ANNUAL GENERAL INSPECTION
Sealing integrity is essential. Every 12 months, verify all gaskets are in proper condition. Should the door gaskets adhere slightly to the unit when opening a
door, lubricate its surface with a transparent grease or petroleum jelly. Should unit be moved on occasion, ensure that rubber grommets are tightly fastened.
Disconnect the unit by unplugging the power cord from the wall,
and access the fan section. Verify that the acoustic insulation is well
fastened to the walls. In the event of a problem, call your authorised distributor for spare parts and replace immediately.

QUATRO
Air Technologies Inc.
----------------------------------------------------------------
Engineers Of Clean Air
----------------------------------------------------------------
30 Hymus Boulevard, Montreal, Quebec, H9R 1C9 Tel.: (514) 630-4444 Fax: (514) 630-4454 website: www.quatroair.com info@quatroair.com
WARNING: DO NOT OPERATE UNIT UNLESS ALL FILTERS ARE IN PLACE.
RESETTING MICROPROCESSOR AFTER FILTER(S) HAVE BEEN REPLACED
Resetting Microprocessor After FILTER Replacement , WHILE “Service Filters” Led is SOLID
1- Ensure motor access door is closed
2- Plug power back to the unit
3- When you Press “POWER”, MOTOR WILL START, “Service FILTER(s)” Led stays SOLID
4- While motor is operating, press & hold SPEED UP & DN simultaneously until unit BEEPS
(hold for 10+ seconds, when beeping continuously, release)
5- In this condition, “System ON” Led is FLASHING, “Service Filters” led is SOLID
6- Press SPEED DN until “Service Filters” Led is FLASHING and system is BEEPING continuously
7- Press & HOLD POWER button while “Service Filters” is FLASHING & BEEPING continuously
Release, when it stops BEEPING
8- Led will be OFF and unit will be ready to operate again
Resetting Microprocessor After Filter Replacement, WHILE “Service Filters” Led is OFF
1- Ensure motor access door is closed
2- Plug power back to the unit
3- When you Press “POWER”, MOTOR WILL START
4- While motor is operating, press & hold SPEED UP & DN simultaneously until unit BEEPS
(hold for 10+ seconds, when beeping continuously, release)
5- In this condition, “System ON” Led is FLASHING
6- Press SPEED DN until “Service Filters” Led is FLASHING
7- Press & HOLD POWER button while “Service Filters” is FLASHING, Release, when it stops BEEPING
8- Led will be OFF and unit will be ready to operate again
BLOWER MAINTENANCE – INFINITY MOTORS, NO BRUSH CHANGE REQUIRED
This unit is equipped with an Automatic Motor Optimization System. Motor is equipped with EXTENDED LENGTH MOTOR BRUSHES. Estimated duration can
be up to 2000-4000 hours and is dependent on many factors such as continuous use and motor speed. To avoid downtime “Service Motor(s) Led will illuminate
when motor is approximately 90% worn. This allows you the time to purchase new motors, and have them available for when the motors expire.
When Automatic Motor and Brush Optimization System estimates motor(s) have been worn to dangerous level, appropriate LED will illuminate.
To optimize and ensure longest motor life, AFTER REPLACEMENT, START motor right away reset the LED as per instructions below, speed will automatically
default to LOW. Operating the motor at Low speed for 15 minutes will “break-in” the new motor, optimizing and prolonging their life.
WARNING: Switch unit off and unplug power cord from wall before servicing the blower.
TURN UNIT UPSIDE DOWN, Access to the motors is through the bottom plate as pictured below.
Motor section from outside Motor section from inside Motors close-up, with support
Filter Bags (AG259 or AG149 depending on your application) located behind front access door
Separation grille:
Must be placed right below FILTER BAGS, so the filter below the Filter Bags does not clog
Odor Filter (Not Pictured) located below Filter Bags (above HEPA Filter). Part number varies by application.
Not required for all applications. (ALWAYS PLACE SEPARATION GRILLE ABOVE ODOR FILTER)
HEPA Filter (F074) located at bottom below the filters, behind front access door.

QUATRO
Air Technologies Inc.
----------------------------------------------------------------
Engineers Of Clean Air
----------------------------------------------------------------
30 Hymus Boulevard, Montreal, Quebec, H9R 1C9 Tel.: (514) 630-4444 Fax: (514) 630-4454 website: www.quatroair.com info@quatroair.com
1- Using a ¼” socket, unscrew the 4 bolts holding down the motor
2- Remove the motor WITH motor support bracket from the unit
3- Separate motor from motor support bracket by unscrewing 4 screws
4- Replace motor with new motor, and re-install as above
(see Detailed Replacement instructions below)
ALWAYS REPLACE BOTH MOTORS AT THE SAME TIME
OR THE WEAR RATES OF THE BRUSHES WILL NEVER BE IN SYNC.
Detailed Replacement
1- Disconnect wires, cut zip ties.
2- Remove the retaining nuts & lock washer holding the motor assemblies.
3- Remove the motor retaining bracket from the old motor. Note the orientation on the bracket.
4- Verify the gasket design (See the beginning of the Motor Service & Replacement Section)
5- Install the bracket on the new motor. If the bracket is installed incorrectly it may result in a short to ground for the
brush contacting the bracket. The curved brush must be visible in the large cutout as per Figure below
6- Install the assembly back into the unit & connect the wires. Install new zip ties.
On units equipped with iSeries controls reset the Service Motors(s) Alarm by following the instruction below.
BLOWER MAINTENANCE
WARNING: Switch unit off and unplug power cord from wall before servicing the blower.
LED Diagnostic Table - “Service Motor(s)” Alerts
If “Service Filter(s)” alert is ON SOLID the motor(s) need to be serviced or replaced.
MOTOR ACCESS: The motor access panel is located below the unit..
Motor support brackets
(4) screws holding motor to each bracket
(8) Bolts holding down the 2 motors
Motor is accessed from below the unit
Motors installed in this device are rated for approximately
20000 operating hours.

QUATRO
Air Technologies Inc.
----------------------------------------------------------------
Engineers Of Clean Air
----------------------------------------------------------------
30 Hymus Boulevard, Montreal, Quebec, H9R 1C9 Tel.: (514) 630-4444 Fax: (514) 630-4454 website: www.quatroair.com info@quatroair.com
Replacement Instructions
ALLOW MOTOR(S) TO COOL FOR 45 MINS BEFORE SERVICING
1- Unplug power cord and open motor access panel.
2- Disconnect wires, cut zip ties.
3- Remove the retaining nuts & lock washer holding the motor assemblies.
4- Remove the motor retaining bracket from the old motor. Note the orientation on the bracket.
5- Install the bracket on the new motor. See the installations pictures below.
THIS IS PARTICULARLY IMPORTANT. If the bracket is installed incorrectly it may
result in a short to ground for the brush contacting the bracket. The curved brush must be visible in the large
cutout as per Figure 2 above.
6- Install the assembly back into the unit & connect the wires. Install new zip ties.
7- Plug in power cord and Reset “Service Motor(s) Alert. This MUST be done EVEN IF L2 IS NOT ILLUMINATED or the
motor(s) replacement alert will not function correctly. Follow the instructions below.
1- Ensure filter access door is closed
2- Plug power back to the unit
3- Press & hold SPEED UP & DN simultaneously until unit BEEPS
4- Hold for 10+ seconds, when panel is beeping continuously, release buttons
5- You are now in RESET MENU, in this condition, “System ON” Led is FLASHING QUICKLY
6- Press SPEED DN (1 Time) until “Service Motor(s)” LED is FLASHING
7- Press & HOLD POWER button while “Service Motor(s) LED is FLASHING & unit is BEEPING continuously
8- Release, when LED stops FLASHING & stops BEEPING
Motor contains double shielded ball bearings with a special lubricant, assuring long life and quiet operation. No extra motor
maintenance is required.
RESETTING MICROPROCESSOR CONTROLLER AFTER REPLACING MOTORS
Resetting Microprocessor After Motor Replacement WHILE “Service Motor(s)” Led is SOLID
1- Ensure motor access door is closed 2- Plug power back to the unit
3- When you Press “POWER”, MOTOR WILL START, “Service Motor(s)” Led stays SOLID
4- While motor is operating, press & hold SPEED UP & DN simultaneously until unit BEEPS
(hold for 10+ seconds, when beeping continuously, release)
5- In this condition, “System ON” Led is FLASHING, “Service Motor(s)” led is SOLID
6- Press SPEED DN (once) until “Service Motor(s)” Led is FLASHING and system is BEEPING continuously
7- Press & HOLD POWER button while “Service Motor(s)” is FLASHING & BEEPING continuously
Release, when it stops BEEPING, and motor operates in LOW speed
8- Operate unit at LOW SPEED for 10-15 minutes to break-in new brushes (to prolong brush life)
Resetting Microprocessor After Motor Replacement, WHILE “Service Motor(s) Led is OFF
1- Ensure motor access door is closed 2- Plug power back to the unit
3- When you Press “POWER”, MOTOR WILL START
4- While motor is operating, press & hold SPEED UP & DN simultaneously until unit BEEPS
(hold for 10+ seconds, when beeping continuously, release)
5- In this condition, “System ON” Led is FLASHING
6- Press SPEED DN (once) until “Service Motor(s)” Led is FLASHING
7- Press & HOLD POWER button while “Service Motor(s)” is FLASHING
Release, when it stops BEEPING, and motor operates in LOW speed
8- Operate unit at LOW SPEED for 10-15 minutes to break-in new brushes (to prolong brush life)
Unplug POWER cord from unit, Replace motor(s) as per instructions above, close motor access door.
MOTOR WILL DEFAULT TO LOWEST SPEED AFTER A RESET. YOU WILL PROLONG MOTOR BRUSH LIFE IF YOU BREAK THEM IN, SO IT IS ADVISED TO LET
MOTOR OPERATE AT LOWEST SPEED FOR 15 MINUTES
TROUBLESHOOTING, MECHANICAL GUIDE
Symptoms
Possible Cause
Suggested Solution
Unit will not start
Faulty power supply
Circuit breaker popped
Motor burnt
Brushes worn
Check breaker box
RESET circuit breaker on unit panel
Replace motor (PN: AB001)
Replace Brushes (PN: AB112)
Excessive noise
Turbine impeller contacting housing
Replace motor (PN: AB001)
Insufficient airflow Obstruction in system
Clogged filter
Remove obstruction
Replace filter
Motor shuts off
Input amperage too high
Graphite crystal rods are consumed
Motor is burnt
Ensure filter is in place, reset circuit breaker
Replace rods (PN: AG112, 2/pkg)
Replace motor (PN: AB001)
Excessive airflow
Filter not in place
Install filter

QUATRO
Air Technologies Inc.
----------------------------------------------------------------
Engineers Of Clean Air
----------------------------------------------------------------
30 Hymus Boulevard, Montreal, Quebec, H9R 1C9 Tel.: (514) 630-4444 Fax: (514) 630-4454 website: www.quatroair.com info@quatroair.com
Suction varies from workstation to
workstation
Hose lengths between stations vary Adjust damper or blast gate at each station equalizing suction
WARRANTY
QUATRO Air Technologies (QUATRO) warrants its equipment to be free from defect in material and workmanship under
normal use and service for a period of one year from date of shipment. QUATRO's obligation under this warranty shall be
limited to replacing any parts, thereof, which shall be demonstrated to have been defective. This is expressly in lieu of all
other warranties, express or implied, including the warranties of merchantability and fitness.
QUATRO claims no warranty as to merchantability or as to the fitness of the merchandise for any particular use and shall not
be liable for any loss or damage. No person, firm or corporation is authorised to assume for QUATRO any other liability in
connection with the sale of these goods. Equipment, parts and material manufactured by others and incorporated in
QUATRO's equipment are warranted by QUATRO only to the extent of the original manufacturer's liability to QUATRO.
Conditions and Limitations: This warranty does not cover abuse, misuse, maintenance negligence, improper assembly,
acts of vandalism, acts of God, fear wear, modifications of the equipment or installation of a part not recommended by
QUATRO, as well as operation of the equipment at voltages other than those specified by QUATRO
.
REPLACEMENT PARTS LIST
CollectALL MedEVAC MultiPure PowerStation2
Description CA- MMP- PS216-
HEPA Filter F074 F074 F074
Filter Bags (2/pak) - AG259-02 AG259-02
Filter Bags (6/pak) AG149 AG259-06 AG259-06
Filter Bags (12/pak) - AG259-12 AG259-12
Odor Container Refill NC-GPC -
Rhodium Odor Refill NC-BPC - -
Solder Fume Odor Refill NC-GPC
Rhodium & Solder Fume Odor Refill F109 - -
Blower Turbine Assy 120V (2) AR175 (2) AR175 (2) AR175
Blower Turbine Assy 230V (2) AR176 (2) AR176 (2) AR176
Brushless Turbine Assy (120v) (1)AB045-16 (1)AB045-16 (1)AB045-16
Brushless Turbine Assy (230v) (1)AB045-25 (1)AB045-25 (1)AB045-25

QUATRO
Air Technologies Inc.
----------------------------------------------------------------
Engineers Of Clean Air
----------------------------------------------------------------
30 Hymus Boulevard, Montreal, Quebec, H9R 1C9 Tel.: (514) 630-4444 Fax: (514) 630-4454 website: www.quatroair.com info@quatroair.com
LED Diagnostics Table, R18
Light
(LED)
Status
Audible
Alert
Condition Description/Action
System
SOLID
Unit is ON
LED 1
(L1)
Flashing
Slowly
AUDIBLE ALERT
MUTED
Alarm Condition MUTED, See L2, L3 Or L4 for specific alarm condition
Service
Motors
LED 2
(L2)
SOLID
Beep
Every
4 Hrs
Motor(s) Will Soon
Need Service
“Quick Change” Brush Motors WILL SOON Require Brush Replacement
INFINITY motor Brush WILL SOON Require Complete Replacement
Brushless Motors Are Almost At The End Of The Predicted Service Life
RESET ALERT After Service!!
See “Motor Service & Replacement” Section For More Motor Info & Reset Alert
Instructions
SOLID
Beep
Every
15 Min
Motor(s) Service
Becoming Urgent
“Quick Change” Brush Motors ONLY: Replace Brushes ASAP And RESET
ALERT, See “Motor Service & Replacement” Section For More Info & Reset
Alert Instructions
SOLID
Beep
Every 5
Min
Motor(s) Service
Required
IMMEDIATELY
“Quick Change” Brush Motors ONLY: Replace Brushes IMMEDIATELY And
RESET ALERT
See “Motor Service & Replacement” Section For More Info & Reset Alert
Instructions
SOLID
Motor Alarm Muted
L1 Flashing Slowly
Replace Brushes OR Motor(s) ASAP And RESET ALERT
Alarm Mute Details On Previous Page
See “Motor Service & Replacement” Section For More Motor Info & Reset Alert
Instructions
Service
Filter(s)
LED 3
Flashing
Slowly
*Filter Pressure High Prepare To Replace/Service Filters
See “Filter Service & Replacement” Section For More Info & Filter
Service/Replacement Instructions
(L3)
Flashing
Slowly
Beep
Every
Hour
*Filter Pressure Near
Critical, Service
Becoming Urgent
Replace Filters. See Filter Service/Replacement For More Info.
Continued Operation May Result In Unit Shutdown.
High Pressure Causes Excess Motor Heat & Accelerates Brush Wear.
Flashing
Slowly
Beep
Every
Second
*Critical Pressure Unit Has Shutdown To Prevent Damage From Excess Pressure
Verify Blockage – Remove Blockage
Verify All Filters – Clean/Replace Filters Accordingly
See “Filter Service & Replacement” Section For More Info
SOLID
Beep
Every
Hour
Filter(s) Service Life
Expired
Replace Filter(s) ASAP And RESET ALERT
See “Filter Service & Replacement” Section For More Info & Reset Alert
Instructions
SOLID
Filter Alarm Muted
L1 Flashing Slowly
Replace Filter(s) ASAP And RESET ALERT
Alarm Mute Details On Previous Page
See “Filter Service & Replacement” Section For More Info & Reset Alert
Instructions
Remote
Standby
SOLID
Receiving Remote
Signal
Remote Switch Closed (On) OR Receiving Remote Signal From Another Piece
Of Equipment
LED 5
(L5)
Fading
IN-OUT
Shutdown Delay Quatro System Continues To Run For A Short Period To Remove All Debris
From Work Area
Flashing
Slowly
Unit Is In Standby Waiting For Remote Switch To Close (Turn On) OR To Receiving Remote
Signal From Another Piece Of Equipment
ALL
LEDS
Flashing
Slowly
Beep
Every
Second
* Low System Pressure Abnormally Low Pressure, Unit will BEEP & Shutdown In 5 Seconds
Unit Will Continue To Shutdown Unit Until The Issue Is Addressed
-Motor(s) Not Operating Due To Service Required Or Failure
Service (Change Brushes) Or Replace Motor(s) & RESET ALERT Alert
See “Motor Service & Replacement” Section For More Motor Info & Reset Alert
Instructions
-Motors Not Operating Due To Excess Heat.
Check For Line Blockage, Service/Replace Filters. Let Motor(s) Cool For
30Min.
See “Filter Service & Replacement” Section For More Info & Reset Alert
instructions, -Access Door(s) Open. Close All Access Doors
-Filters Not Or Improperly Installed. Verify Filters

QUATRO
Air Technologies Inc.
---------------------------------------------------------
Engineers Of Clean Air
--------------------------------------------------------
30 Hymus Boulevard, Montreal, Quebec, H9R 1C9 Tel.: (514) 630-4444 Fax: (514) 630-4454 website: www.quatroair.com [email protected]m
Light Diagnostics Table G16.13 or G17.13 and higher
Light Led1
System
ON
Led2
Service
Motor
Led3
Service
Filter
Led4
Filter
Clean
Led5
Remote/
Standby
Audible
Alert
Condition Action
System
Operation
SOLID
None Unit is operating using POWER
button on panel, no remote signal
Remote or mc2 has a shutdown delay of approximately 5-10
seconds
Fading
Temporary ON mode Pressing the POWER button while Led5 is Flashing will temporarily
disable any active remote standby.
ONLY main motor is operational, to do temporary cleaning using
dust collector.
To Re-Establish STANDBY turn the unit off using the POWER
button.
SOLID
SOLID None
Unit is operating using remote
signal
SOLID
Fading
IN-OUT
None Shutdown delay
(Remote signal has been removed)
Remote has a shutdown delay of approximately 5-10 seconds
Flashing
None Unit is in Standby mode, waiting for
remote signal (or mc2 signal if
provided) to start unit
Low
System
Pressure
Flashing
Flashing
Flashing
Flashing
Beep Every
Second
Abnormally Low Pressure, Unit will
BEEP until addressed
Check motor(s), Check motor brushes, verify if filters are installed,
close all filter access points,
(available only on JS-5222, not on JS-5200)
Service
Motors
SOLID
Beep Every
4 Hours
50 hrs of life left in brushes Replace motors. Reset Motor Life Alert
120v-PN: AR175 or 230v-PN: AR176
Service
Filters
Flashing
None Filter Pressure High Prepare To Replace/Service Filters
(available only on JS-5222, not on JS-5200)
Flashing
Beep Every
Hour
Filter Pressure Close To Critical Replace/Service Filters Now. Continued Operation may Result In
Unit Shutdown, (available only on JS-5222, not on JS-5200)
Flashing
Beep Every
Second
Critical Pressure, Unit BEEPING
CONSTANTLY
Verify Blockage, Verify All Filters
(available only on JS-5222, not on JS-5200)
SOLID Beep Every
Hour
Replace Filter (s) ASAP Replace Filter (s) ASAP