RADEX QUARTA User manual

This manual suits for next models

2

Other RADEX Measuring Instrument manuals

RADEX OBSIDIAN User manual

RADEX

RADEX OBSIDIAN User manual

RADEX QUARTA RD1212 User manual

RADEX

RADEX QUARTA RD1212 User manual

RADEX RD1212-BT User manual

RADEX

RADEX RD1212-BT User manual

RADEX RD1503 User manual

RADEX

RADEX RD1503 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

PREPARATION FOR OPERATION
Fitting power elevents
1. Open the battery compartment lid.
2. Insert two batteries ("AAA")
3. Close the battery compartment.
, , functions can be changed depending on application.
Flashlight
Key
Mini-USB
Display
Key
Key
Result
The rst measurement result will appear
on display after about 10 seconds.
󰀨
Press and hold for a few seconds.
Switching on
Press .
DISPLAY LAYOUT
Icons 1- 5, 11, 12 are displayed when the device is turned on.
1. Audible alarm
2. Measuring Cycle in progress
3. Vibration On/O󰀨
4. Backlighting
5. Bluetooth On / O󰀨
6. Atmospheric pressure
7. Key function
8. Key function
9. Measurement result
10. Air temperature
11. Key function
12. Date: Day - Month - Year
13. Time
14. Background Radiation
15. Alarm threshold
16. Power battery charge level
- high
•
•
•
- low (battery to be
replaced).
17. Unit of measurement:
micro Sievert per hour
18. Indicates that a quantum was
detected,when ashing.
19. Number of measurement cycles
performed
DEVICE OPERATION
Measurement
Measurements begin when the device is turned on.
TIP: Normally, we recommend keeping the Background Mode o󰀨, unless you are
scanning a specic object in a new environment. This mode takes 5 consec-
utive readings to establish base-line background radiation in your immediate
area, and then shows any readings higher than the established baseline.
а- excess over (b) b- baseline background radiation
Result
1 16171819
8910
11
12
13
14
15
2
3
4
5
6
7

This device is intended to measure the background ionizing radiation of the
environment as well as products and materials.
APPEARANCE
Battery compartment
Battery
compartment lid
a
b
Measurement with Background Mode
When making measurements with Background Mode ON, two results are
displayed simultaneously:
MENU
• to enter the menu press , main menu will appear on display
• use buttons or to move the cursor . Use button to select
• moving the cursor to choose the desired function and to select it.
Symbol will appear/disappear next to the desired function to indicate that
it has been selected/deselected.
• After 30 seconds of inactivity the device will exit to main menu.
• when batteries are removed, the date and time will reset after 40 hours
DATA TRANSFER
Bluetooth connecon to smartphone or tablet only (iOS or Andorid).
Download RadexRead free app from AppStore or PlayStore.
USB connecon to Computer - Windows only.
Download soware from www.quartarad.com - Support - RD1212-BT
• Save the measurements on your PC.
• Share on the World Map.
• See data from other users on the World Map.
• Save your data for personal use only.
• Chart your data for easy review and analysis.

To activate the ashlight, press and hold for a few seconds.
Radiation: How much is harmful?
Not all radiation is the same, so scientists use the ‘sievert’ to measure the health
risks of radiation.
A one-sievert dose of radiation would cause immediate radiation sickness. But
most radiation doses are much smaller, so you’ll see them measured in mil-
lisieverts or even smaller microsieverts.
1 sievert (Sv) = 1000 millisieverts (mSv)
1 millisievert (mSv) = 1000 microsieverts (uSv)
uSv/h micro Sieverts per hour.
0.10 This is low, it does not get any lower.
0.21 Pretty normal. Depends on local geology.
0.42 Happens occasionally with no real reason.
Just keep an eye on it.
0.83 ALERT - No need to panic, but try to gure
out what is going on, stay out of the rain
and avoid unnecessary trips.
1.25 Real risk of cancer if exposed for a year.
4.17 Real risk of cancer if exposed for 90 days.
20,000 Annual limit for Nuclear Plant Workers.
100,000 Annual limit for Fukushima workers.
Sievert calculations based on Cesium-137 isotope.
TECHNICAL SPECIFICATION
Range of Indications µSv/h 0,05 to 999
Energy range of registered:
Gamma radiation
X-radiation
Beta-radiation
MeV
0,1 to 1,25
0,03 to 3,0
0,4 to 3,5
Margin of Error
where Р – dose power in µSv/h %± (15+6/Р)
Alarm threshold (increments of 0.05) µSv/h 0,05 to 1,2
Measurement cycle sec 10
Detection continous
Batteries ("AAA") pieces 2
Uninterrupted operation time* hours 300
Temperature range (humidity should not exceed
85% at 25 oC / 77 oF) °С -18 to +45
°F -0.5 to +113
Device dimensions mm 97 x 68 x 24
in 3.8 x 2.7 x 1
Weight (without batteries) kg 0,08
oz 2.8
* At factory settings, natural background conditions, no use of ashlight.

Threshold - 0,30 µSv/h ● Audible alarm - ON ● Data collection - OFF
Vibrato signal - OFF ● Backlighting - OFF
Please be advised that the measurement results obtained with the use of
󰀩󰀩
government body has approved the use of this device.
WHAT IS INCLUDED
RADEX RD1212-BT
AAA Batteries x2
USB cable
Quarta-Rad, Inc.
[email protected]