RadiaCode 10 Series User manual


Personal radiation detector Radiacode-10X series. User manual.I
© 2023 Radiacode Ltd.
Contents
Chapter I Introduction 1
................................................................................................................................... 2
1 Appointment of the device
................................................................................................................................... 3
2 Device design
................................................................................................................................... 4
3 Technical specifications
................................................................................................................................... 5
4 Developer contacts
Chapter II Safety precautions and warnings 6
Chapter III Stand-alone use of the device 9
................................................................................................................................... 10
1 Before use
................................................................................................................................... 11
2 Buttons
................................................................................................................................... 12
3 Turning on and off
................................................................................................................................... 12
4 Display
................................................................................................................................... 13
5 Icons
................................................................................................................................... 14
6 Indication: sound, vibration, light
................................................................................................................................... 15
7 Battery charging
................................................................................................................................... 15
8 Firmware update
................................................................................................................................... 16
9 Menu usage
................................................................................................................................... 17
10 Device settings
.......................................................................................................................................................... 18Selecting units of measurement
.......................................................................................................................................................... 19Count rate - alarm levels
.......................................................................................................................................................... 20Dose rate - alarm levels
.......................................................................................................................................................... 21Dose - alarm levels
.......................................................................................................................................................... 22Display settings
.......................................................................................................................................................... 23Signals - sound, vibration, light
.......................................................................................................................................................... 26Bluetooth settings
.......................................................................................................................................................... 27Language selection
.......................................................................................................................................................... 27Time settings
.......................................................................................................................................................... 28Reset to factory settings
................................................................................................................................... 29
11 Display Modes
.......................................................................................................................................................... 29Spectrum
.......................................................................................................................................................... 30Monitor
.......................................................................................................................................................... 31Dose
.......................................................................................................................................................... 32Search
.......................................................................................................................................................... 33Device info
................................................................................................................................... 33
12 Alarms
Chapter IV Working with a smartphone 36
Chapter V Work with a PC 38
Index 40

Chapter
I

2
© 2023 Radiacode Ltd.
Introduction
1 Introduction
This section contains the general information about dosimeter Radiacode-10Xseries. Later in the
document, the dosimeter Radiacode-10Xseries is also referred to as "device" and "dosimeter".
1.1 Appointment of the device
Radiacode-10X series
Portable dosimeter personal radiation detector Radiacode-10X series is designed to assess the radiation
situation in real time. In addition, the instrument automatically keeps a log of measurement results and
events. This makes it possible to analyze them, including with the help of standard software on a
smartphone or personal computer. The dosimeter is suitable for work on the ground, with samples of
construction materials, with specially selected and prepared food or soil samples.
The instrument has high sensitivity to gamma and X-ray radiation.
It is suitable for assessing dose rate, accumulated dose, absorbed radiation energy spectrum and
radiation hazard warning.
Personal radiation detector Radiacode-10X series is a universal tool for radiation safety assessment.
With it, it is always available for:
site reconnaissance;
·
inspection of objects and materials;
·
continuous monitoring of the radiation situation;
·
automatic data storage in the instrument's memory;
·
accumulated dose monitoring;
·
quick search for radiation sources;
·
two-channel alarm signaling of radiation danger and changes in the radiation situation;
·
time-based database;
·
possibility of autonomous operation, or in pair with a smartphone;
·
wireless data transmission;
·
wide possibilities of data processing in Windows, Android and IOS applications.
Instrument features
·
Fast response to changes in the radiation environment, thanks to the CsI(Tl) scintillator detector
working together with a silicon photomultiplier tube and adaptive processing of incoming data.
·
Continuous assessment of the radiation situation as long as the instrument is switched on. Results at
any moment can be presented in the form of dose rate, count rate, accumulated dose, absorbed
radiation energy spectrum. Assessment and accumulation of data do not depend on the change of the
display mode.
·
Splash-proof, dust-proof - IP64 class.
·
Long autonomous operation from the built-in battery.
·
Independent alarm thresholds for count rate exceedance, dose rate exceedance and accumulated
dose exceedance. Possibility to set 2 thresholds for each value.
·
Built-in non-volatile memory for data accumulation, the volume of about 1000 hours of autonomous
observations. Possibility to transfer data to a computer via USB and to a smartphone via Bluetooth.
Storage of results in an external database.

Introduction 3
© 2023 Radiacode Ltd.
·
Binding of results to geographic coordinates and display on Google and OSM maps when used in
conjunction with a smartphone.
·
Availability of a program for personal computer and applications for Android and IOS.
·
Continuous development of the project. Possibility of software upgrades.
·
Economical graphic display with automatic backlighting in the dark. Rotation of the image on the
screen when the device is rotated.
·
Sound, light and vibration alarms on the device, and the ability to duplicate them on a smartphone.
Radiacode-10X series is a highly sophisticated and sensitive instrument. Please read the
instructions to obtain reliable results.
1.2 Device design
Design elements, controls and indications
controls and indications personal radiation detector Radiacode-10X series
1. Location of the radiation sensor, digital thermometer, and instrument orientation sensor.
2. Ambient light sensor to turn on the screen backlight in the dark.
3. Status of the built-in battery: charge level, charging, end of charging (powered from external
source).
4. Control button lock indication.
5. External connection: USB, Bluetooth.
6. Audio indication status.
7. Presence, source and level of alarm.
8. Temperature of the radiation sensor.
9. Current time.
10. Swing button "up", when the display image is reversed, "down".
11. USB type C connector for charging the device and data exchange.
12. Power and confirmation button, round.

4
© 2023 Radiacode Ltd.
Introduction
13. Swing button "down", when the display image is turned upside down.
14. Graphical representation of dose rate.
15. Numerical representation of dose rate.
16. Source of audible indication.
17. Units of numerical representation of dose rate.
18. Light indication:
- charge (blue color);
- gamma-quantum registration (green in normal, red when the alarm threshold is exceeded).
19. Random error of dose rate estimation.
1.3 Technical specifications
General technical characteristics
Energy range of registered photon radiation (X-ray and
gamma)
0.03…3 MeV
Dose rate assessment:
§
range (by Cs-137)
§
error
§
time (display update period)
§
time for a level of random error ±15% with natural
radiation background 0.08 µSv/h
0.1…1000 uSv/h
±15%
0.5 s
34 s
Accumulated dose assessment:
§
range
0…10 Sv
Non-volatile memory:
§
registration volume of Standalone mode
last 1000 h
Continuous operation time (for fully charged battery)
up to 500 h
Built-in battery:
§
type and capacity
§
charging voltage, typical
§
charging current, max
§
full charge time, typical
Li-Pol 3.7 V, 1000 mAh
5 V
500 mA
2 h
Operating temperature range
-10…+45°C
Relative humidity, max
85 %
Wire connection:
§
type
§
cable
§
current consumption, max
USB 2.0 and higher
type C
500 mA
Wireless connection
BLE (Bluetooth 4.0 and higher)
Display
Monochrome graphic LCD, 128x48
pixels, 34x13 mm, FSTN,
Transflective, Positive
Dimensions, W*H*D
123x34x18 mm
Weight
65 g
Dust and moisture protection, code
IP64
Requirements for

Introduction 5
© 2023 Radiacode Ltd.
The device works with personal computers with minimum system requirements:
- Windows XP/7/8/10 operating system;
- RAM (RAM) not less than 2 GB;
- video card with resolution not worse than 1024x768;
- free space on the hard disk not less than 1 GB;
- USB port 1 pc.
Technical requirements to the mobile device
The device works with tablets or smartphones with minimum system requirements:
Android operating system version 6.0 and higher.
The device works with iPhone and iPad devices with minimum system requirements:
iOS operating system 17.0 or higher, or macOS 14.0 or newer and MAC with Apple chips.
1.4 Developer contacts
Radiacode Ltd.
3 Thalia Street, Office 222, Limassol 3011, Cyprus
Тел. +357 96 207695
E-mail: support@radiacode.com
Web:https://radiacode.com

Chapter
II

Safety precautions and warnings 7
© 2023 Radiacode Ltd.
2 Safety precautions and warnings
Read this manual carefully before using the device.
·
Keep the device out of the reach of children and pets!
·
Do not disassemble the device! Repair of the device is allowed only in certified service centers.
·
Do not use defective chargers! Use only dedicated chargers or USB port of computer to charge
the device! A device damaged as a result of improper charging is not eligible for warranty repair.
·
Protect your device from extreme temperatures (below -20 ° C or above +45 ° C). Temperatures that
are too high or too low will reduce the capacity of the battery and shorten its life.
·
Avoid getting the device wet. Moisture can cause serious damage to the device. Moisture penetration
into the device will void the manufacturer's warranty.
·
If you brought the package with the device from frost to a warm room, leave it to warm up for two hours
without opening. Otherwise, moisture may condense inside the device and cause the device to
malfunction.
·
Do not use or store the device in dirty areas.
·
Avoid exposing the device to strong electromagnetic fields.The action of the electromagnetic field can
damage the device.
·
Mobile phones, electronic and household appliances can interfere with the operation of the device.
·
External shocks and rough handling can seriously damage the electronics of the device.
·
Do not grip the device strongly in your hand, press the buttons lightly.
·
Handle the device with care, the display is made of glass and can be broken if handled roughly.
·
Do not disconnect the device from the computer while the firmware is being updated. An attempt to
disrupt the download process may lead to a malfunction of the device, which can only be fixed by a
certified service center.
FCC warning.
Federal Communications Commission (FCC) Statement. This device complies with part 15 of the FCC
Rules. Operation is subject to the following twoconditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide Reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one ormore of the following measures:
·
Reorient or relocate the receiving antenna.
·
Increase the separation between the equipment and receiver.
·
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
·
Consult the dealer or an experienced radio/TV technician for help.
Warning: Changes or modifications made to this device not expressly approved by Radiacode LTD may
void the FCC authorization to operate this device.Note: The manufacturer is not responsible for any radio
or TV interference caused by unauthorized modifications to this equipment. Such modifications could
void the user’s authority to operate the equipment.

8
© 2023 Radiacode Ltd.
Safety precautions and warnings
RF exposure statement:
This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment.
The device is installed and operated without restriction.

Chapter
III

10
© 2023 Radiacode Ltd.
Stand-alone use of the device
3 Stand-alone use of the device
Portable dosimeter personal radiation detector Radiacode-10Xseries is designed to assess the radiation
situation in real time. In addition, the instrument automatically keeps a log of measurement results and
events. This makes it possible to analyze them, including with the help of standard software on a
smartphone or personal computer. The dosimeter is suitable for work on the ground, with samples of
construction materials, with specially selected and prepared food or soil samples.
Radiacode-10X series is designed for long-term autonomous use. Results at any moment can be
presented in the form of dose rate estimation, count rate, accumulated dose, absorbed radiation energy
spectrum. Assessment and accumulation of data do not depend on the change of display mode.
The instrument allows storing the accumulated data in the internal memory up to thousand last hours of
observations.
In addition to autonomous operation personal radiation detector can be connected to a personal
computer via USB cable or to an Android or iOS smartphone via Bluetooth. Connection to an Android
smartphone is also possible via USB OTG. When connected to a computer or smartphone, the
accumulated data are transferred to an external device, and the newly received data are transferred there
immediately without being stored in the built-in memory.
To connect the device to a computer it is necessary to install software Radiacode.
The program is available for download at https://space.radiacode.com.
With the help of the program Radiacode you can transfer data to a computer, view it and manage it
personal radiation detectorом.
For a detailed description of the program interface, see in chapter "Working with the use of a computer".
To work with a smartphone install the app on it Radiacode,
available at https://space.radiacode.com and GooglePlay,
or use the QR code:
3.1 Before use
Note: If you brought the package with the device from frost to a warm room, leave it to warm up
for two hours without opening. Otherwise, moisture may condense inside the device and cause
the device to malfunction. Moisture penetration into the device will void the manufacturer's warranty.
First steps:
·
take the device out of the package;
·
make sure it is intact;
·
read the instructions;
·
check the completeness according to the product passport;
·
check the availability and correctness of filling in the passport/warranty card;
·
fully charge the battery.

Stand-alone use of the device 11
© 2023 Radiacode Ltd.
After the battery is fully charged, turn on the device and set the current time. After it, you may
additionally:
·
select menu language;
·
set display parameters;
·
set up signals;
·
update firmware of the device.
3.2 Buttons
Personal radiation detector Radiacode-10X series has an intuitive menu system and is controlled by
three buttons.
Sound and vibration indication are also helpful in operating the instrument.
The device is
in the left hand
in the right hand
1. round button for turning on and confirming;
2. swing button "down";
3. swing button "up".
There are two types of pressing the buttons: short and long (at least two seconds).
A long press on the round button [1] is used to
·
turn on the instrument;
·
unlock the swing buttons;
·
call up the menu;
·
confirm viewing of the presented list of maximum alarm levels;
·
in some setup screens.
A short press of the round button is used to:
·
to lock the swing buttons;
·
return from the main menu to the display mode;
·
confirm selection of the highlighted menu item;
·
toggle the selection options.
·
to turn off the alarms.
The swing buttons are automatically locked after 5, 10, 15, 30 seconds of inactivity. At the same time,
the backlight of the screen is switched off, if it was on. In addition, there are 2 additional time intervals for
the display backlighting - 2 and 5 minutes, the swing buttons are locked after 30 seconds of inactivity.
The time until the backlight auto-locks and turns off depends on the settings.
You can unlock these buttons by long pressing the round button [1]. This will also turn on the screen
backlight, if it is enabled in the instrument settings.
If there is sufficient light in the "Auto" mode, the backlight will not be switched on. The buttons can be
switched back to the locked state by briefly pressing the round button [1].
A short press on the up/down swing buttons [2, 3] is used to:
·
move between menu items;
·
setting numerical values.
·
additional options in different modes.

12
© 2023 Radiacode Ltd.
Stand-alone use of the device
Long press on the up/down swing buttons[2, 3] is used for different purposes in different cases.
In menus, a long press on the up/down swing buttons[2, 3] leads to a quick selection of items.
In scene display modes, a long press on the "up" swing button turns the sound indication on and off.
Which of the swing buttons will be "up" and which will be "down" depends on the screen orientation
settings.
When moving through the menu at any level, the selected item will be presented in negative - light on
dark.
Detailed description of using the buttons in different modes can be found in the sections "Display Modes"
и "Menu Usage".
Pressing any button is accompanied by a short sound and vibration, depending on the settings.
*The sound and vibration accompanying button presses can be turned off.
3.3 Turning on and off
To include Radiacode-10X series click on round button and hold it down for three seconds.
The device can be switched off via the menu.
·
To turn on the instrument, press and hold the round button until the
instrument turns on (at least 3 seconds).
oWhen the instrument is turned on, it will be in Monitor mode.
oWith the appropriate settings, the power on. sound will be played at this
moment.
oWith the appropriate settings, the vibration indication. will be played at
this moment.
oAt appropriate settings, the display backlight will be turned on at this
point.
·
To turn off, press and hold the round button of the instrument until the
menu icons appear (at least 3 seconds).
oIcon display indicates that the swing buttons are locked.
oTo unlock, press and hold the round button (at least 3 seconds).
·
Short presses on the up or down swing buttons move the cursor to the
shutdown icon .
·
A short press on the round button will turn the appliance off.
oWith the appropriate settings, a shutdown sound will be played at this
point.
oThe instrument screen will be turned off.
3.4 Display
The instrument is equipped with a graphical monochrome
display.

Stand-alone use of the device 13
© 2023 Radiacode Ltd.
·
Monochrome graphic LCD;
·
128x48 dots;
·
34x13 mm;
·
FSTN, transflective, positive;
·
built-in backlight.
*Handle with care, the display may be broken or scratched if handled carelessly.
The screen is equipped with a backlight for operation in the dark.
The device automatically detects the light level when the setting is set to "Auto". In this case, the
backlight is turned on only when the button is pressed. In bright light, for example in the sun, the
backlight will not turn on.
The backlight brightness has ten gradations.
You can set the orientation of the image on the screen for left or right handed operation, or select the
automatic rotation mode.
Power on conditions, backlight time, backlight brightness and image orientation are set via the menu,
section Settings.
The display is used to show:
·
instrument status;
·
graphical dose rate level;
·
control menu;
·
settings menu;
·
spectrum mode, for estimation of absorbed radiation energies;
·
monitor mode, for estimation of dose rate;
·
Dose mode, for estimation of accumulated dose;
·
search mode, for visual estimation of count rate.
The status panel is placed in the upper part of the display. The content of the status panel depends on
the selection of the display mode.
The type and meaning of the icons used are described in more detail in the section Icons.
3.5 Icons
Various icons are used to label fields on the instrument status panel.
At least 60% charge.
At least 30% charge.
At least 10% charge.
Less than 10% charge, the battery needs to be recharged.
The battery is being charged.
Charge completed, external power supply.

14
© 2023 Radiacode Ltd.
Stand-alone use of the device
The "swing" buttons are locked.
USB communication has been established.
Bluetooth communication has been established.
All sounds are off.
Sounds included.
Level 1 alarm on Count Rate.
Level 2 alarm on Count Rate.
Count Rate over-range alarm.
Level 1 Dose Rate alarm.
Level 2 Dose Rate alarm.
Dose Rate over-range alarm.
Level 1 alarm on Dose.
Level 2 alarm on Dose.
Dose off-scale alarm.
Linear scale of the amplitude of the energy spectrum of photon radiation.
Logarithmic scale of the amplitude of the energy spectrum of photon radiation.
In the menu (enter by long pressing the round button), the sections are indicated by icons and text.
Settings
Instrument settings menu.
Spectrum
Display of the energy spectrum of radiation.
Monitor
Display the current dose rate or count rate.
Dose
Display of accumulated dose of photon radiation (gamma and X-ray).
Search
Search mode - display the count rate as a graph.
Power off
Turning off the device.
About device
Information about the dosimeter serial number and software version.
3.6 Indication: sound, vibration, light
In personal radiation detectorе Radiacode-10X series sound and vibration sources are built in to
acknowledge button presses and to indicate events and alarms. A light indication is provided for remote
monitoring
Sound can be accompanied by:
·
switching the device on and off;
·
pressing a button;

Stand-alone use of the device 15
© 2023 Radiacode Ltd.
·
establishment of communication via Bluetooth;
·
registration of radiation quantum;
·
exceeding alarm thresholds;
·
low battery warning;
·
response to the "Search for device" request.
Vibration can be accompanied by:
·
switching the device on and off;
·
pressing the button;
·
exceeding alarm thresholds;
·
response to the "Search for the device" request.
Light indication:
·
battery charging - blue color, continuous glow;
·
registration of radiation quantum in normal conditions - green color, flash;
·
registration of radiation quantum in case of alarm - red color, flash;
·
exceeding the alarm threshold - switching on the screen backlight.
It is possible to turn signals on or off the alarms by separate groups:
·
all sounds;
·
button pressing sound;
·
sound of radiation quantum registration;
·
all types of vibration;
·
light indication.
3.7 Battery charging
To charge the battery:
·
plug the USB cable to the connector located at the end of the device ([14] in the general view);
·
plug the USB cable to the connector of a computer or a special charger;
·
leave the device connected to the charging source until it is fully charged.
The indicator of the activity of the charging process is the glowing of the blue indicator ([18] in the general
view). If the device is turned on, then the screen displays the icon ([3] in the general view). At the end of
the charging procedure, the blue indicator will turn off and the icon will change to the sign of power
supply from an external source.
Pay attention to the charge indicator icon while using the device. If the charge indicator is empty ,
then connect the device to the charger.
Attention! Use only dedicated chargers or a computer USB port to charge the device. Connecting
the device to the wrong charging source may damage it. A device damaged as a result of
improper charging is not eligible for warranty repair.
3.8 Firmware update
The device is constantly being improved and the firmware (built-in software) is regularly updated by the
developer company. The current version of the device firmware is available through the Device info menu
item.
To update the firmware take the following steps:
·
download the latest version of Radiacode software at https://space.radiacode.com;
·
install Radiacode on your computer and run it;
·
connect the device directly to your computer's USB port using the USB cable type-C (supplied with the
device);
·
turn on the device;
·
if there is a fresh version of the firmware, you will be prompted to update it;
·
wait for the update process to finish.
Update the firmware using your smartphone and the Android app:

16
© 2023 Radiacode Ltd.
Stand-alone use of the device
·
install the latest version of the Android application in the application store: Radiacode or download from
the link: https://space.radiacode.com;
If the device bootloader is version 4.0 or higher - it is possible to update the firmware via Bluetooth:
launch the application;
·
call the menu by pressing the button with three horizontal dashes on the top left;
·
select "Devices";
·
select Bluetooth communication interface and confirm by pressing the [OK] button;
·
after connecting the device, confirm the firmware update of the device;
·
wait for the download and update process to complete. The red LED will be on during the update
process.
If the device bootloader is lower than version 4.0 you will need a USB OTG adapter for your
smartphone:
·
connect the instrument with the cable and adapter to your smartphone;
·
Allow the RadiaCode app to be used with the connected device;
·
launch the app;
·
access the menu by pressing the button with three horizontal dashes on the top left;
·
select "Devices";
·
select the USB communication interface and confirm by pressing the [OK] button;
·
confirm the firmware update of the instrument;
·
wait for the update process to complete.
Attention! Do not turn off the instrument and do not disconnect the USB cable until the
process is complete!
Violation of the firmware update process may lead to instrument failure.
Please contact the service department to restore operation.
3.9 Menu usage
Let's take the state "The device is off" as the initial state.
·
Press and hold the round button until the instrument
turns on (at least 3 seconds);
oWhen turned on, the instrument will be in the Monitor
and display the dose rate;
oWith the appropriate settings, the sound power on will
be played at this time.
oAt appropriate settings at this moment the backlight
of the display will be turned on.
·
Press and hold the round button to move to the menu;
oThe name of the current menu item will be displayed
at the top. (In this case it is "Monitor");
oThe icons of the main menu items will be placed
vertically;
oThe active item will be highlighted with a negative
icon.
There are seven menu items available on the main menu level.
Settings
Device settings - go to the submenu;
Spectrum
Photon radiation energy spectrum (gamma and X-ray) - display mode;
Monitor
Dose rate, count rate - display mode;

Stand-alone use of the device 17
© 2023 Radiacode Ltd.
Dose
Accumulated dose - display mode;
Search
Count rate search graph - display mode
Power off
Turning off the appliance is an action;
About device
Serial number and software version information.
Use a short press on the up/down swing buttons to select the desired item. The selected item will be
highlighted with a negative icon. To confirm the selection, use a short press on the round button.
Only three selections are available on the instrument screen at a time, the others will become available
when the up/down swing buttons are pressed again.
Of the seven items, four [ Spectrum, Monitor, Dose, Search] give access to the
selection of the radiation situation display mode.
Item [ Power off] – is an action point, if it is confirmed with the round button, the instrument will be
switched off.
Item [ Settings] is used to go to the submenu of the instrument settings.
Item [ About device] is used to obtain information about the instrument number and firmware and
bootloader versions.
At all levels, the menu is arranged in a cyclical fashion. For example, on the main level, pressing the
down swing button moves the focus from item to item in the following order: --> --> --> -->
--> --> --> ...
3.10 Device settings
The instrument settings can be accessed from the corresponding instrument submenu –
"Settings".
·
Press and hold the round button until you reach the
menu;
·
The name of the current menu item will appear at the
top. (In this case it is "Monitor");
oThe icons of the main menu items will be placed
vertically;
oThe active item will be highlighted with a negative
icon.
·
Short presses on the upper swing button (or the lower
one, the menu is circular) focus on the item
"Settings";
·
Press the round button briefly to confirm access to
the "Settings" submenu.
Next, short presses on the up/down buttons of the swings can be used to move the focus to the desired
item and make the required settings.
This and deeper menu levels can be exited via [< Back] and [<< Menu quit].

18
© 2023 Radiacode Ltd.
Stand-alone use of the device
Selecting units of measurement
Count rate - alarm levels
Dose rate - alarm levels
Dose - alarm levels
Display settings
Signals - sound, vibration, light
Bluetooth settings
Language selection
Time settings
Device info
Reset to factory settings
3.10.1 Selecting units of measurement
·
Briefly press the up/down rocker buttons to move
the focus to [Measurement units];
·
Short press the round button to move to
[Measurement units].
·
Short presses on the round button to select dose
rate measurement units:
·
Sv - Sievert or R - Roentgen;
·
Short presses on the up/down swing buttons
move the focus to the item [Count Rate].
·
Short presses on the round button to select the
units of count rate estimation:
·
CPS - Count Per Second;
·
CPM - Count Per Minute.
·
To return to the previous level or exit the menu,
briefly press the up/down swing buttons to move
the focus to [< Back] or [<< Menu quit];
·
Briefly press the round button to confirm your
selection;
This manual suits for next models
1
Table of contents
Popular Security Sensor manuals by other brands

TREND
TREND OCC/U installation instructions

JCM Technologies
JCM Technologies NEOCELL-15M Operating and installation instructions

FloodMaster
FloodMaster FM-094 Series installation manual

Honeywell
Honeywell Fire-Lite Alarms SD365T Installation and maintenance instructions

Powerfix Profi
Powerfix Profi PMDL 5 B1 operating instructions

SKYLOTEC
SKYLOTEC CS2 Instructions for use