R&S SMCVB-K164 User manual

R&S®SMCVB-K164
DVB-T2
User Manual
User Manual
Version 02
1179097402
(;Ý9Ø2)

This document describes the following software options:
●R&S®SMCVB-K164
1434.3890.02
This manual describes firmware version FW 4.70.176.xx and later of the R&S®SMCV100B.
© 2020 Rohde & Schwarz GmbH & Co. KG
Mühldorfstr. 15, 81671 München, Germany
Phone: +49 89 41 29 - 0
Email: [email protected]
Internet: www.rohde-schwarz.com
Subject to change – Data without tolerance limits is not binding.
R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG.
Trade names are trademarks of the owners.
1179.0974.02 | Version 02 | R&S®SMCVB-K164
The following abbreviations are used throughout this manual: R&S®SMCV100B is abbreviated as R&S SMCVB, R&S®WinIQSIM2 is
abbreviated as R&S WinIQSIM2

Contents
R&S®SMCVB-K164
3User Manual 1179.0974.02 ─ 02
Contents
1 Preface.................................................................................................... 7
1.1 About this Manual......................................................................................................... 7
1.2 Documentation Overview............................................................................................. 8
1.2.1 Getting Started Manual................................................................................................... 8
1.2.2 User Manuals and Help...................................................................................................8
1.2.3 Service Manual............................................................................................................... 8
1.2.4 Instrument Security Procedures......................................................................................9
1.2.5 Printed Safety Instructions.............................................................................................. 9
1.2.6 Data Sheets and Brochures............................................................................................ 9
1.2.7 Release Notes and Open Source Acknowledgment (OSA)............................................ 9
1.2.8 Application Notes, Application Cards, White Papers, etc................................................9
2 Welcome to the DVB-T2 Option.......................................................... 10
2.1 Accessing the DVB-T2 Dialog....................................................................................10
2.2 Scope............................................................................................................................11
2.3 Notes on Screenshots................................................................................................ 11
3 About the DVB-T2 Option....................................................................12
3.1 Required Options........................................................................................................ 12
4 DVB-T2 Configuration and Settings................................................... 13
4.1 General Settings..........................................................................................................13
4.2 Input Signal Settings.................................................................................................. 16
4.2.1 General Settings........................................................................................................... 17
4.2.2 PLP Info........................................................................................................................ 20
4.2.3 T2-MI Data Packet Timing Settings...............................................................................22
4.2.4 Test Signal Settings.......................................................................................................25
4.2.5 IP Channnel x Settings..................................................................................................27
4.3 Mode & Stream Settings.............................................................................................30
4.3.1 PLP 0 Settings.............................................................................................................. 30
4.3.2 PLP Info........................................................................................................................ 32
4.4 BICM Settings..............................................................................................................35
4.4.1 PLP 0 Settings.............................................................................................................. 36

Contents
R&S®SMCVB-K164
4User Manual 1179.0974.02 ─ 02
4.4.2 PLP Info........................................................................................................................ 38
4.5 OFDM Settings............................................................................................................ 39
4.6 System Settings.......................................................................................................... 42
4.6.1 Network Settings........................................................................................................... 43
4.6.2 L1 Settings.................................................................................................................... 47
4.6.3 ID Settings.....................................................................................................................49
4.7 SFN Settings................................................................................................................50
4.7.1 Delays........................................................................................................................... 51
4.7.2 Mode............................................................................................................................. 52
4.8 Frame Info....................................................................................................................54
4.8.1 Frame............................................................................................................................54
4.8.2 Symbols........................................................................................................................ 55
4.8.3 L1 Signaling.................................................................................................................. 56
4.8.4 Data Cells......................................................................................................................57
4.9 Data Generation Settings........................................................................................... 58
4.10 Global Connector Settings.........................................................................................59
4.11 TS Player......................................................................................................................59
4.11.1 TS Player Settings........................................................................................................ 60
4.11.2 Player Output................................................................................................................ 63
4.11.2.1 General......................................................................................................................... 64
4.11.2.2 Stuffing.......................................................................................................................... 65
4.11.3 Seamless Loop Settings............................................................................................... 67
4.12 Local IP Data Network Settings................................................................................. 68
5 Performing DVB-T2 Signal Generation Tasks................................... 71
5.1 Configuring the Input Signal......................................................................................71
5.1.1 How to Apply an External IP Input Signal..................................................................... 71
5.1.2 How to Apply an External TS Input Signal.................................................................... 74
5.1.3 How to Generate an Internal TS Signal........................................................................ 75
5.2 Monitoring the Input Signal........................................................................................75
5.2.1 How to Monitor External IP Input Data..........................................................................76
5.2.2 How to Monitor an External TS Input Signal................................................................. 76
5.2.3 How to Monitor an Internal TS Player Signal................................................................ 77
6 Remote-Control Commands............................................................... 78

Contents
R&S®SMCVB-K164
5User Manual 1179.0974.02 ─ 02
6.1 General Commands.................................................................................................... 79
6.2 Input Commands.........................................................................................................81
6.2.1 General Commands...................................................................................................... 81
6.2.2 PLP Info Commands..................................................................................................... 85
6.2.3 T2-MI Packet Timing Commands..................................................................................88
6.2.4 Test Signal Commands................................................................................................. 90
6.2.5 IP Subsystem................................................................................................................ 92
6.3 Mode and Stream Commands....................................................................................95
6.4 BICM Commands...................................................................................................... 101
6.5 OFDM Commands..................................................................................................... 106
6.6 System Commands...................................................................................................109
6.6.1 Network Commands....................................................................................................109
6.6.2 L1 Commands............................................................................................................. 114
6.6.3 ID Commands..............................................................................................................118
6.7 SFN Delay Commands.............................................................................................. 119
6.8 Frame Info Commands............................................................................................. 124
6.8.1 Frame and Symbol Duration Commands....................................................................125
6.8.2 L1 Signaling Commands............................................................................................. 127
6.8.3 Data Cell Commands.................................................................................................. 129
6.9 TSGen Subsystem.................................................................................................... 129
6.10 BCIP Subsystem....................................................................................................... 137
Annex.................................................................................................. 141
A DVB-T2 Test Cases............................................................................ 141
Glossary: Abbreviations....................................................................142
Glossary: Specifications................................................................... 145
List of Commands..............................................................................146
Index....................................................................................................150

Contents
R&S®SMCVB-K164
6User Manual 1179.0974.02 ─ 02

Preface
R&S®SMCVB-K164
7User Manual 1179.0974.02 ─ 02
1 Preface
1.1 About this Manual
This user manual provides all the information specific to the DVB-T2 option
R&S SMCVB-K164. All general instrument functions and settings common to all appli-
cations and operating modes are described in the main R&S SMCV100B user manual.
The main focus in this manual is on the provided settings and the tasks required to
generate a signal. The following topics are included:
●Welcome to the DVB-T2 option R&S SMCVB-K164
Introduction to and getting familiar with the option
●About the DVB-T2
Background information on basic terms and principles in the context of the signal
generation
●DVB-T2 Configuration and Settings
A concise description of all functions and settings available to configure signal gen-
eration with their corresponding remote control command
●How to Generate a Signal with the DVB-T2 Option
The basic procedure to perform signal generation tasks and step-by-step instruc-
tions for more complex tasks or alternative methods
●Remote Control Commands
Remote commands required to configure and perform signal generation in a
remote environment, sorted by tasks
(Commands required to set up the instrument or to perform common tasks on the
instrument are provided in the main R&S SMCV100B user manual)
Programming examples demonstrate the use of many commands and can usually
be executed directly for test purposes
●Glossary
Alphabetical list of often used terms and abbreviations and specifications.
●List of remote commands
Alphabetical list of all remote commands described in the manual
●Index
Contents and scope
This description assumes R&S SMCV100B equipped with all available options.
Depending on your model and the installed options, some of the functions may not be
available on your instrument.
Notes on screenshots
When describing the functions of the product, we use sample screenshots. These
screenshots are meant to illustrate as much as possible of the provided functions and
possible interdependencies between parameters. The shown values may not represent
realistic usage scenarios.
About this Manual

Preface
R&S®SMCVB-K164
8User Manual 1179.0974.02 ─ 02
The screenshots usually show a fully equipped product, that is: with all options instal-
led. Thus, some functions shown in the screenshots may not be available in your par-
ticular product configuration.
1.2 Documentation Overview
This section provides an overview of the R&S SMCV100B user documentation. Unless
specified otherwise, you find the documents on the R&S SMCV100B product page at:
www.rohde-schwarz.com/manual/smcv100b
1.2.1 Getting Started Manual
Introduces the R&S SMCV100B and describes how to set up and start working with the
product. Includes basic operations, typical measurement examples, and general infor-
mation, e.g. safety instructions, etc. A printed version is delivered with the instrument.
1.2.2 User Manuals and Help
Separate manuals for the base unit and the software options are provided for down-
load:
●Base unit manual
Contains the description of all instrument modes and functions. It also provides an
introduction to remote control, a complete description of the remote control com-
mands with programming examples, and information on maintenance, instrument
interfaces and error messages. Includes the contents of the getting started manual.
●Software option manual
Contains the description of the specific functions of an option. Basic information on
operating the R&S SMCV100B is not included.
The contents of the user manuals are available as help in the R&S SMCV100B. The
help offers quick, context-sensitive access to the complete information for the base unit
and the software options.
All user manuals are also available for download or for immediate display on the Inter-
net.
1.2.3 Service Manual
Describes the performance test for checking the rated specifications, module replace-
ment and repair, firmware update, troubleshooting and fault elimination, and contains
mechanical drawings and spare part lists.
The service manual is available for registered users on the global Rohde & Schwarz
information system (GLORIS):
Documentation Overview

Preface
R&S®SMCVB-K164
9User Manual 1179.0974.02 ─ 02
https://gloris.rohde-schwarz.com
1.2.4 Instrument Security Procedures
Deals with security issues when working with the R&S SMCV100B in secure areas. It
is available for download on the Internet.
1.2.5 Printed Safety Instructions
Provides safety information in many languages. The printed document is delivered with
the product.
1.2.6 Data Sheets and Brochures
The data sheet contains the technical specifications of the R&S SMCV100B. It also
lists the options and their order numbers and optional accessories.
The brochure provides an overview of the instrument and deals with the specific char-
acteristics.
See www.rohde-schwarz.com/brochure-datasheet/smcv100b
1.2.7 Release Notes and Open Source Acknowledgment (OSA)
The release notes list new features, improvements and known issues of the current
firmware version, and describe the firmware installation.
The open-source acknowledgment document provides verbatim license texts of the
used open source software.
See www.rohde-schwarz.com/firmware/smcv100b
1.2.8 Application Notes, Application Cards, White Papers, etc.
These documents deal with special applications or background information on particu-
lar topics.
See www.rohde-schwarz.com/application/smcv100b
Documentation Overview

Welcome to the DVB-T2 Option
R&S®SMCVB-K164
10User Manual 1179.0974.02 ─ 02
2 Welcome to the DVB-T2 Option
The R&S SMCVB-K164 is a firmware application that adds functionality to generate
signals in accordance with the DVB-T2 digital standard.
The R&S SMCVB-K164 option features:
●DVB-T2 signal generation
This user manual contains a description of the functionality that the application pro-
vides, including remote control operation.
All functions not discussed in this manual are the same as in the base unit and are
described in the R&S SMCV100B user manual. The latest version is available at:
www.rohde-schwarz.com/manual/SMCV100B
Installation
You can find detailed installation instructions in the delivery of the option or in the
R&S SMCV100B service manual.
2.1 Accessing the DVB-T2 Dialog
To open the dialog with DVB-T2 settings
► In the block diagram of the R&S SMCV100B, select "Baseband > DVB-T2".
A dialog box opens that displays the provided general settings.
The signal generation is not started immediately. To start signal generation with the
default settings, select "State > On".
Accessing the DVB-T2 Dialog

Welcome to the DVB-T2 Option
R&S®SMCVB-K164
11User Manual 1179.0974.02 ─ 02
2.2 Scope
Tasks (in manual or remote operation) that are also performed in the base unit in the
same way are not described here.
In particular, it includes:
●Managing settings and data lists, like storing and loading settings, creating and
accessing data lists, or accessing files in a particular directory.
●Information on regular trigger, marker and clock signals and filter settings, if appro-
priate.
●General instrument configuration, such as checking the system configuration, con-
figuring networks and remote operation
●Using the common status registers
For a description of such tasks, see the R&S SMCV100B user manual.
2.3 Notes on Screenshots
When describing the functions of the product, we use sample screenshots. These
screenshots are meant to illustrate as many as possible of the provided functions and
possible interdependencies between parameters. The shown values may not represent
realistic usage scenarios.
The screenshots usually show a fully equipped product, that is: with all options instal-
led. Thus, some functions shown in the screenshots may not be available in your par-
ticular product configuration.
Notes on Screenshots

About the DVB-T2 Option
R&S®SMCVB-K164
12User Manual 1179.0974.02 ─ 02
3 About the DVB-T2 Option
The transmission standard complies with the specification ETSI EN 302 755 and ETSI
TS 102 773. A subset of all possible parameters found in the specification can be set
on the R&S SMCV100B.
3.1 Required Options
The equipment layout for generating DVB-T2 signals includes:
●Base unit
●Option Enable Broadcast Standard (R&S SMCVB-K519)
●Option DVB-T2 (R&S SMCVB-K164)
Required Options

DVB-T2 Configuration and Settings
R&S®SMCVB-K164
13User Manual 1179.0974.02 ─ 02
4 DVB-T2 Configuration and Settings
Access:
► Select "Baseband > DVB-T2".
This section provides an overview on the DVB-T2 settings.
The remote commands required to define these settings are described in Chapter 6,
"Remote-Control Commands", on page 78.
Settings:
●General Settings..................................................................................................... 13
●Input Signal Settings............................................................................................... 16
●Mode & Stream Settings......................................................................................... 30
●BICM Settings......................................................................................................... 35
●OFDM Settings........................................................................................................39
●System Settings...................................................................................................... 42
●SFN Settings...........................................................................................................50
●Frame Info...............................................................................................................54
●Data Generation Settings........................................................................................58
●Global Connector Settings...................................................................................... 59
●TS Player................................................................................................................ 59
●Local IP Data Network Settings.............................................................................. 68
4.1 General Settings
Access:
► Select "Baseband > DVB-T2".
General Settings

DVB-T2 Configuration and Settings
R&S®SMCVB-K164
14User Manual 1179.0974.02 ─ 02
The tab provides default settings, save and recall settings and settings necessary
to configure T2-MI interface parameters.
The remote commands required to define these settings are described in Chapter 6.1,
"General Commands", on page 79.
Settings:
State..............................................................................................................................14
Set To Default................................................................................................................14
Save/Recall...................................................................................................................14
T2-MI Interface..............................................................................................................15
T2-MI PID (Hex)............................................................................................................15
T2-MI SID (Hex)............................................................................................................15
Data Generation............................................................................................................15
Test Cases.................................................................................................................... 15
└Test Cases...................................................................................................... 15
Reset Log File...............................................................................................................15
Status Info.....................................................................................................................16
State
Activates the standard and deactivates all the other digital standards and digital modu-
lation modes in the same path.
Remote command:
[:SOURce<hw>]:BB:T2DVb:STATe on page 79
Set To Default
Calls the default settings. The values of the main parameters are listed in the following
table.
Parameter Value
State Not affected by the "Set to Default"
Remote command:
[:SOURce<hw>]:BB:T2DVb:PRESet on page 79
Save/Recall
Accesses the "Save/Recall" dialog, that is the standard instrument function for saving
and recalling the complete dialog-related settings in a file. The provided navigation
possibilities in the dialog are self-explanatory.
The filename and the directory, in that the settings are stored, are user-definable; the
file extension is however predefined.
See also, chapter "File and Data Management" in the R&S SMCV100B user manual.
Remote command:
[:SOURce<hw>]:BB:T2DVb:SETTing:CATalog? on page 80
[:SOURce<hw>]:BB:T2DVb:SETTing:DELete on page 80
[:SOURce<hw>]:BB:T2DVb:SETTing:LOAD on page 80
[:SOURce<hw>]:BB:T2DVb:SETTing:STORe on page 80
General Settings

DVB-T2 Configuration and Settings
R&S®SMCVB-K164
15User Manual 1179.0974.02 ─ 02
T2-MI Interface
Activates the T2-MI modulator interface.
"On" Uses the incoming T2-MI stream to configure the modulator.
"Off" Uses the incoming MPEG transport stream directly as payload for
single PLP transmission.
Remote command:
[:SOURce<hw>]:BB:T2DVb:INPut:T2MI:INTerface on page 83
T2-MI PID (Hex)
Requires "T2-MI Interface > On".
Sets the PID.
The PID belongs to MPEG transport stream packets, that contain T2-MI data.
Remote command:
[:SOURce<hw>]:BB:T2DVb:INPut:T2MI:PID on page 83
T2-MI SID (Hex)
Requires "T2-MI Interface > On".
Sets the T2-MI transport SID.
Use the SID, when transmitting a composite signal, in accordance with annex I of the
specification ETSI EN 302 755.
Remote command:
[:SOURce<hw>]:BB:T2DVb:INPut:T2MI:PID on page 83
Data Generation
Accesses the "DVB-T2 Data Generation" dialog.
See Chapter 4.9, "Data Generation Settings", on page 58.
Test Cases
Accesses a standard file-select dialog to select DVB-T2 test cases.
For available test cases, see Chapter A, "DVB-T2 Test Cases", on page 141.
Test Cases ← Test Cases
Filters the list of available test cases.
Reset Log File
Requires "T2-MI Interface > On".
Resets the log file.
Status information of the T2-MI analyzer as displayed in "Status Info" is stored to a log
file. The log file DVBT2_T2MI_Status_Info_TX.txt is stored to the directory var/
user/log.
See also, chapter "File and Data Management" in the R&S SMCV100B user manual.
Remote command:
[:SOURce<hw>]:BB:T2DVb:INPut:T2MI:RESetlog on page 84
General Settings

DVB-T2 Configuration and Settings
R&S®SMCVB-K164
16User Manual 1179.0974.02 ─ 02
Status Info
Displays the status of the T2-MI analyzer by an error message. "No Error" implies cor-
rect behavior of the analyzer. Status information of the T2-MI analyzer is stored to a log
file, see "Reset Log File" on page 15.
To ensure correct behavior, fix occurring errors successively.
Remote command:
[:SOURce<hw>]:BB:T2DVb:INPut:T2MI:ANALyzer? on page 83
4.2 Input Signal Settings
Access:
► Select "Baseband > DVB-T2 > Input Signal".
The dialog provides settings necessary to configure the input signal.
Input signal tasks
The settings allow you to perform the following tasks:
●Selecting an MPEG TS or T2-MI source
●Displaying information about the selected stream (e.g. data rate)
●Configuring the internal MPEG TS test packets
How to: Chapter 5.1, "Configuring the Input Signal", on page 71
Settings:
●General Settings..................................................................................................... 17
●PLP Info.................................................................................................................. 20
●T2-MI Data Packet Timing Settings........................................................................ 22
●Test Signal Settings.................................................................................................25
●IP Channnel x Settings............................................................................................27
Input Signal Settings

DVB-T2 Configuration and Settings
R&S®SMCVB-K164
17User Manual 1179.0974.02 ─ 02
4.2.1 General Settings
Access:
► Select "Input Signal > General".
The tab provides general settings necessary to configure the input signal.
Settings:
T2-MI Interface..............................................................................................................17
Source ..........................................................................................................................17
Number of PLPs............................................................................................................18
Input ............................................................................................................................. 18
Input Format .................................................................................................................18
IP TS Channel...............................................................................................................19
T2-MI PID (Hex)............................................................................................................19
T2-MI SID (Hex)............................................................................................................19
Stuffing.......................................................................................................................... 19
Test Signal.....................................................................................................................19
T2-MI Interface
Activates the T2-MI modulator interface.
"On" Uses the incoming T2-MI stream to configure the modulator.
"Off" Uses the incoming MPEG transport stream directly as payload for
single PLP transmission.
Remote command:
[:SOURce<hw>]:BB:T2DVb:INPut:T2MI:INTerface on page 83
Source
Sets the modulation source for the input signal.
Input Signal Settings

DVB-T2 Configuration and Settings
R&S®SMCVB-K164
18User Manual 1179.0974.02 ─ 02
"External" Uses a transport stream, that is input at the "TS IN"/"IP Data" inter-
face.
For more information about connecting to the interfaces, see also:
●"TS IN" interface: Section "Configuring the Global Connectors" in
the R&S SMCV100B user manual.
●"IP Data" interface: Chapter 4.12, "Local IP Data Network Set-
tings", on page 68.
"TS Player" Uses an internal transport stream with TS packet data played from a
file. The player requires no option.
Playing encrypted files with extension _c requires a stream library
option R&S SMCVB-KSx.
See also:
●Chapter 4.11, "TS Player", on page 59
●Supported TS player file types
"Test Signal" Requires "T2-MI Interface > Off".
Uses an internal test signal as specified in Chapter 4.2.4, "Test Signal
Settings", on page 25.
Remote command:
[:SOURce<hw>]:BB:T2DVb:SOURce on page 82
Number of PLPs
Displays the number of PLPs.
The available number of PLPs depends on the setting of "T2-MI Interface":
●If "T2-MI Interface > Off", the number of PLPs is "1" (single PLP).
●If "T2-MI Interface > On", maximum "1 to 20" PLPs are supported.
Remote command:
[:SOURce<hw>]:BB:T2DVb:INPut:NPLP? on page 86
Input
Requires "Source > External".
Sets the external input interface.
"TS IN" Input for serial transport stream data. The signal is input at the "User
1" connector.
"IP" Input for IP-based transport stream data (TSoverIP). The signal is
input at the "IP Data" connector.
Remote command:
[:SOURce<hw>]:BB:T2DVb:INPut on page 82
Input Format
Requires "Source > External" and "Input > TS IN".
Sets the format of the input signal.
"ASI" ASI format
"SMPTE 310" SMPTE 310 format
Remote command:
[:SOURce<hw>]:BB:T2DVb:INPut:FORMat on page 82
Input Signal Settings

DVB-T2 Configuration and Settings
R&S®SMCVB-K164
19User Manual 1179.0974.02 ─ 02
IP TS Channel
Requires "Source > External" and "Input > IP".
Selects the IP-based transport stream (TS) channel. You can select 1 out of 4 IP TS
channels as input at the "IP Data" interface.
To configure a particular channel, see Chapter 4.2.5, "IP Channnel x Settings",
on page 27.
Remote command:
[:SOURce<hw>]:BB:T2DVb:INPut:TSCHannel on page 84
T2-MI PID (Hex)
Requires "T2-MI Interface > On".
Sets the PID.
The PID belongs to MPEG transport stream packets, that contain T2-MI data.
Remote command:
[:SOURce<hw>]:BB:T2DVb:INPut:T2MI:PID on page 83
T2-MI SID (Hex)
Requires "T2-MI Interface > On".
Sets the T2-MI transport SID.
Use the SID, when transmitting a composite signal, in accordance with annex I of the
specification ETSI EN 302 755.
Remote command:
[:SOURce<hw>]:BB:T2DVb:INPut:T2MI:PID on page 83
Stuffing
Requires "External/TS Player".
Activates stuffing.
"On" Inserts null packets and corrects the PCR values.
"Off" The data rate of the transport stream source must match the data
rate required for the current modulation parameters.
Remote command:
[:SOURce<hw>]:BB:T2DVb:PLP<ch>:INPut:STUFfing on page 87
Test Signal
Requires "T2-MI Interface > Off" and "Source > Test Signal".
Defines the test signal data.
"Test TS Packet"
Standardized packet data used as modulation data in the transport
stream. To configure the packet structure, select the side tab "Test
Signal > Test TS Packet".
Uses a null packet as the test signal. To configure the null packet, see
Chapter 4.2.4, "Test Signal Settings", on page 25.
Remote command:
[:SOURce<hw>]:BB:T2DVb:PLP<ch>:INPut:TESTsignal on page 91
Input Signal Settings

DVB-T2 Configuration and Settings
R&S®SMCVB-K164
20User Manual 1179.0974.02 ─ 02
4.2.2 PLP Info
Access:
► Select "Input Signal > PLP Info".
The tab displays the "PLP <num>" table, that contains individual PLP information of
up to 20 PLPs.
The information comprises input parameters for each PLP.
Settings:
PLP <num> table.......................................................................................................... 20
└PLP Input Format............................................................................................20
└Packet Length ................................................................................................20
└Stuffing............................................................................................................21
└Max. Useful Data Rate / Mbit/s....................................................................... 21
└Measured Data Rate / Mbit/s.......................................................................... 21
└Useful Data Rate / Mbit/s................................................................................21
PLP <num> table
Displays individual parameters for each PLP <num>. The table displays information of
up to 20 PLPs with <num> ranging from 0 to 19.
PLP Input Format ← PLP <num> table
Displays the input format of each PLP <num> for all input sources.
"GFPS/GCS/GSE" require "T2-MI Interface > On".
To edit the input format, select "Input Signal > General > Input Format".
"TS" Transport stream
"GFPS" Generic fixed-length packetized stream
"GCS" Generic continuous stream
"GSE" Generic stream encapsulation
Remote command:
[:SOURce<hw>]:BB:T2DVb:PLP<ch>:INPut:FORMat on page 86
Packet Length ← PLP <num> table
Requires "T2-MI Interface > Off" and "Source > External".
Displays the packet length of the external transport stream in bytes.
If the packet length does not match the specified length, the output signal is erroneous.
"Packet Length > Invalid" is displayed.
Input Signal Settings
Table of contents
Other R&S Portable Generator manuals
Popular Portable Generator manuals by other brands

Cromtech
Cromtech TG6000DVE Operation manual

DTI
DTI WINCO PSS15B2W/A Installation and operator's manual

Anritsu
Anritsu 680 B Series Maintenance manual

MULTIQUIP
MULTIQUIP GA-6HZ Parts and operation manual

Sears
Sears CRAFTSMAN 919.679500 owner's manual

MULTIQUIP
MULTIQUIP WHISPERWATT DCA-220SSVU Operation and parts manual