Calibratingthescanner
Youneedtoperformcalibrationinordertoensuretheworkofthescannerafter the
adjustment of lenses.Specificallyforthispurposeweusethecalibration plate, which is
pre-measured withhighaccuracy.Scanningsoftwareanalyzestheimage of the plate,
obtained from thecamerasandcomparesitwiththemathematical model, marked by
the algorithm.
Thereare3typesofcalibration:Fullcalibration,automaticcalibration,fast calibration
(orientation) and Calibration ofturntable(findingthetableaxis).
Full and automatic calibrations are used:
●before work with the scanner,
●after transporting the scanner.
Fast calibration is used:
●if you suspect that the camera moved due to unreliable mounting,
●if you want to check the accuracy of performed calibration.
Calibration of rotary table is performed:
●in case of any change in the position of the rotary table to the scanner
(when scanning on the turntable).
Calibration of rotary table is described in the Scanning on the turntable section.
Calibrationplate
Calibration plate is a special plate with markers, the distance between which is
measured with high accuracy. It is used for setting up a scanner and its calibration.