Read installation instructions carefully before installing.
This product may contain substances that can be hazardous to the environment if not disposed of properly.
Electrical and electronic equipment should never be disposed of with general household waste but must be
separated for its correct treatment and recovery. Where possible recycle your packaging.
It is recommended that luminaires are installed / maintained by a fully qualified electrician and wired in accordance to the latest IEC standards or national
equivalent.
Mains power must be switched off during any installation or maintenance.
Do not install the luminaire near any heat source.
Do not exceed the nominal supply voltage or amperage ratings.
Make sure the wires have been properly connected before powering on the device.
Non-user replaceable light source - when light sources reaches it's end of life, module must be replaced.
The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 0.3m is not expected.
Risk of fire - required clearance from structural members and building elements as stated below.
Do not use for high risk task area lighting.
Proof against supply voltage polarity reversal.
Reinforced insulation between the supply and the battery circuit.
Recharging device will recharge the battery normally after recharging device operated at 1,1 times rated supply voltage and the maximum of the declared ambient
temperature range with the batteries disconnected and replaced by a short circuit link.
INSTALLATION INSTRUCTIONS
These instructions should be read carefully and kept for future reference
POWER
SUPPLY
FUNCTION
OUTPUT
CURRENT CHARGE 300mA
WORKING
TEMPERATURE 0°C to +40°C
INPUT
CURRENT 35mA Max
200-240VAC, 50/60Hz
OPERATION Maintained
Manual
- This Rapid LED product is covered by a 5 Year warranty
( 2 Year replacement & labour / 3 Years replacement only )
- The battery in this product is covered by a 2 Year warranty
- Proof of purchase must be provided with all warranty claims
- All Rapid LED products must be installed by a licenced Electrical Contractor
- All Rapid LED products come with a warranty that cannot be excluded under the Australian Consumer Law
- Please contact Rapid LED on [email protected] for all warranty claims
Black
White
INSTALLATION & WARNINGS
RAPID BLADE
LED EMERGENCY EXIT LIGHT
TECHNICAL DATA
MODEL # CCT
R9996-S-BK
R9996-S-WH
6000k
6000k
WATTAGE
Max. 3w
Max. 3w
IP RATING
IP20
IP20
TRIM COLOUR
WARRANTY
Class II construction
220-240V / 50~60Hz
TECHNICAL PARAMETERS
POWER
FACTOR >0.3
CHARGE
DURATION
BATTERY
BATTERY
DISCHARGE CURRENT
OUTPUT
CHARGE VOLTAGE
BATTERY
VOLTAGE
TEST
MODE
5.8V-7.15VDC
5.8V-7.15VDC
16H
Manual
450mA
LiFePO4 3.2V 600mAh
EMERGENCY
DISCHARGE DURATION 2H
MOUNTING OPTIONS
Surface Mount
Surface Mount
CLASSIFICATION
C0
C90
D1.25
D2.0
Follow steps 1 & 2 above
CEILING MOUNT
Remove the cover using a flat blade screwdriver, 1.
release the clip by turning to the left
INSTALLATION
PICTOGRAM REPLACEMENT
Remove the frame and acrylic panel1.
by using a flat blade screwdriver
2. Take out the pictogram and install the one required 3. Clip the panel to the housing
2. The top cover can then be removed by sliding it away.
The cover MUST BE mounted prior to attaching to the body
3. Mount cover and connect wiring terminals 4. Battery switch is set to disconnect as factory default.
Make sure the battery is connected
5. Assemble the product by sliding the body into place 6. Lock the clip by turning to the right
WALL MOUNT
3. Knock out the holes for screwing and AC wiring 4. Mount cover to the wall and connect wiring to terminals
5. Battery switch is set to disconnect as factory default.
Make sure the battery is connected
6. Assemble the product by sliding the body into place.
Lock the clip by turning to the right

This manual suits for next models

1

Popular Lighting Equipment manuals by other brands

ATG Electronics UFO user guide

ATG Electronics

ATG Electronics UFO user guide

HEPER OLIVA Installation & maintenance instructions

HEPER

HEPER OLIVA Installation & maintenance instructions

ProLights EclFresnel CT+M user manual

ProLights

ProLights EclFresnel CT+M user manual

SpeedTech Lights K-FORCE 27 TIR instruction manual

SpeedTech Lights

SpeedTech Lights K-FORCE 27 TIR instruction manual

Cameo CLBARL10RGBA user manual

Cameo

Cameo CLBARL10RGBA user manual

Chauvet DJ FLEXstand Quick reference guide

Chauvet DJ

Chauvet DJ FLEXstand Quick reference guide

Hamamatsu ENERGETIQ LDLS EQ-77X Operation manual

Hamamatsu

Hamamatsu ENERGETIQ LDLS EQ-77X Operation manual

Tranberg TEF 2502 user manual

Tranberg

Tranberg TEF 2502 user manual

Acuity Brands Synergy SwitchPak Operation and maintenance manual

Acuity Brands

Acuity Brands Synergy SwitchPak Operation and maintenance manual

IKEA Sunnan manual

IKEA

IKEA Sunnan manual

Uplus Lighting DUAD540 STROBE user manual

Uplus Lighting

Uplus Lighting DUAD540 STROBE user manual

Philips DayLight 8 manual

Philips

Philips DayLight 8 manual

Lumisky LADY C110 user guide

Lumisky

Lumisky LADY C110 user guide

Lightolier Lytecaster 1132T specification

Lightolier

Lightolier Lytecaster 1132T specification

Commercial Electric 54263211 Use and care guide

Commercial Electric

Commercial Electric 54263211 Use and care guide

Signal Mate 2NMSFLASH owner's manual

Signal Mate

Signal Mate 2NMSFLASH owner's manual

Memostar LineFit T5 LED AC150PS1T5 operating instructions

Memostar

Memostar LineFit T5 LED AC150PS1T5 operating instructions

Conrad 1216214 operating instructions

Conrad

Conrad 1216214 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.