6
1. Turn VALVE KNOB to “ON” position (Figure 8A) above.
2. Slide switch on the RECEIVER (Figure 10A) to “REMOTE”
position.
3. Consult Operating Instructions for Accessory Control.
4. Adjust the burner flame height by turning the valve knob
clockwise to lower and counter-clockwise to raise up to
full on. During the heating season
leave valve knob in “PILOT” position for convenience.
Otherwise, turn to “OFF” position for any prolonged
non-use.
ON/OFF SOLENOID
B) PILOT ADJUSTMENT
SCREW
A) VALVE KNOB
C) KNOB POSITION INDICATOR
LIGHTING AND OPERATION
IMPORTANT! YOUR GAS LOG SET SHOULD BE OPERATED FOR THE FIRST 2-3 HOURS AT A LOW FLAME
SETTING TO ALLOW TEMPERING OF THE REFRACTORY LOGS. TO SHUTDOWN OVERNIGHT OR FOR ANY
PROLONGED PERIOD, SLIDE RECEIVER SWITCH TO “OFF” POSITION (Figure 10B above)
FIGURE 10
STEP THREE: BURNER OPERATION
1. The Pilot flame should be steady, surrounding
the THERMOPILE TIP (Figure 9B).
2. If pilot flame adjustment is necessary, use a narrow long
stem flathead screwdriver to turn PILOT ADJUSTMENT
SCREW (Figure 8B) above.
3. Turn clockwise for less flame, counter-clockwise for more.
4. If after pilot adjustment the burner begins to shutdown,
re-adjust for a longer pilot flame.
STEP TWO: PILOT ADJUSTMENT
THERMOCOUPLE
ASSEMBLY
FIGURE 9
1/2”
A) PILOT
B) THERMOCOUPLE TIP
NOTE: The VALVE KNOB has complete control of gas to the pilot and burner. It cannot be turned to “OFF” without first
depressing dial to the “PILOT “ position and then rotating clockwise to “OFF” (see figure 8A).
IMPORTANT!
CHIMNEY DAMPER MUST BE WIDE OPEN! THE FLUE MUST VENT ALL PRODUCTS OF COMBUSTION.
DAMPER AND GLASS DOORS MUST BE FULLY OPEN BEFORE LIGHTING OR BURNING FOR PROPER VENTILATION AND TO
PREVENT HEAT DAMAGE TO VALVE.
FIGURE 8 “EASY” SAFETY VALVE
STEP ONE: PILOT LIGHTING
1. Turn VALVE KNOB (Figure 8A) to “PILOT” position.
2. Depress and hold until air is bled and gas flows to Pilot
(Figure 9A).
3. Light Pilot with a Match or Lighter.
4. Once Pilot is lit, continue to depress and hold until the
Pilot flame remains lit (approximately 30 to 60 seconds).
5. If Pilot does not remain lit, depress and turn Valve Knob
clockwise to “OFF” position and wait at least 5 minutes to
allow gas to dissipate. Repeat steps 1 thru 4.
A) VALVE KNOB TURNED COUNTER
CLOCKWISE TO “ON” POSITION
B) RECEIVER SLIDE
SWITCH IN “REMOTE”
POSITION
KNOB POSITION INDICATOR