Items Needed
1. Put SIM card from designated cellular provider into the cellular interface
2. Attach mounting brackets to the back of the unit using provided hardware
2. Drill a 7/8” hole in appropriate location for data and telephone wiring
3. Make a slit in the provided grommet and insert into the 7/8” hole
4. Connect telephone cable from Elevator Phone to FXS port on 2100-VoIPLCC
5. Connect power cable coming out of enclosure to standard 110VAC wall outlet
Page 3
N56W24720 N. Corporate Circle Sussex, WI 53089
800-451-1460 www.rathcommunications.com
Installation
• Rath 2100-Series Phone
• Name, Authentication Password, and Authentication ID for SIP Extension (from ITSP)
• PC with Network Interface Card attached to same network as SIP server
• Battery backed up 120V power source or RATH® RP7700104
• Standard Analog Telephone (for testing)
VoIP Interface Set-Up
1. Set PC to DHCP and connect to switch
2. Turn o wireless card on computer (if applicable)
3. Connect analog phone to phone port on VoIP Interface
a. Lift handset of analog phone (dial tone should be heard)
b. Dial * , * , * , to enter menu
c. Dial 0 , 2 , to have VoIP Interface playback current IP address (please write down for reference)
d. Dial # , 0 , 3 , to have VoIP Interface playback current subnet mask (please write down for reference)
e. Hang up analog phone
4. Log into VoIP Interface
a. Enter VoIP Interface IP address into web browser (Google Chrome or Mozilla Firefox is preferred)
b. Log into Interface
LOGIN: Admin PASSWORD: Admin
5. Select proper time zone from drop down menu next to Time Zone
6. Click APPLY at the bottom of the page
7. Enter SIP Server information in VoIP Interface
a. Click FXS Port under menu options on the top of the screen
b. Enter SIP Extension ID in in SIP User ID box
c. Enter Authentication ID in Authenticate ID box (can be the same as the SIP Extension ID)
d. Enter Authentication Password in Authenticate Password box
e. Fill in the NAME location as it will appear on the phone
8. Click APPLY at the bottom of the page, then click REBOOT to restart unit